liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Visual and optical performance of the Akreos Adapt Advanced Optics and Tecnis Z9000 intraocular lenses: Swedish multicenter study
Linköping University, Faculty of Health Sciences. Linköping University, Department of Clinical and Experimental Medicine, Ophthalmology. Östergötlands Läns Landsting, Reconstruction Centre, Department of Ophthalmology UHL/MH.
Institute of Clinical Neuroscience, Göteborg University, Göteborg.
Section of Ophthalmology, Göteborg University, Göteborg.
Department of Applied Physics, Stockholm.
Show others and affiliations
2007 (English)In: Journal of cataract and refractive surgery, ISSN 0886-3350, E-ISSN 1873-4502, Vol. 33, no 9, p. 1565-1572Article in journal (Refereed) Published
Abstract [en]

Purpose

To compare the subjective visual and objective optical performance of 2 aspherical intraocular lenses (IOLs), the Akreos Adapt Advanced Optics (AO) (Bausch & Lomb, Inc.) and the Tecnis Z9000 (Advanced Medical Optics, Inc.).

Setting

Four university hospitals in Sweden.

Methods

This study comprised 80 patients, 20 each from 4 university hospital centers in Sweden. All patients had bilateral clear corneal phacoemulsification with implantation of an Akreos Adapt AO IOL in 1 eye and Tecnis Z9000 IOL in the other eye according to a randomization protocol. Preoperatively, 90% contrast Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity was measured and the mesopic pupil sizes were determined. Ten to 12 weeks postoperatively, 12.5% and 90% contrast ETDRS visual acuities and photopic and mesopic Functional Acuity Contrast Test chart contrast sensitivities were determined. Wavefront analysis was performed with the Zywave II aberrometer (Bausch & Lomb, Inc.), and a questionnaire on the subjective quality of vision was completed by each patient.

Results

The Akreos AO IOL and Tecnis Z9000 IOL produced similar high- and low-contrast visual acuities as well as photopic and mesopic contrast sensitivities. The Tecnis Z9000 IOL resulted in lower spherical aberrations of the eye (mean 0.05 ± 0.13 μm versus 0.35 ± 0.13 μm root mean square, 6.0 mm pupil) (P<.001); however, the Akreos AO IOL provided a larger depth of field (mean 1.22 diopter [D] ± 0.48 [SD] versus 0.86 ± 0.50 D, 6.0 mm pupil) (P<.001). Patient satisfaction was generally high, although 68.8% of the patients reported some type of visual disturbance postoperatively. Twenty-eight percent of patients reported better subjective visual quality in the Akreos AO eye and 14%, in the Tecnis Z9000 eye (P<.0001). Accordingly, 33% perceived more visual disturbances in the Tecnis Z9000 eye and 11%, in the Akreos AO eye (P<.0001).

Conclusions

Maximum reduction of spherical aberration did not maximize subjective visual quality. The higher perceived quality of vision with the Akreos AO IOL could be because of differences in depth of field, IOL material, or IOL design.

Place, publisher, year, edition, pages
2007. Vol. 33, no 9, p. 1565-1572
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:liu:diva-48833DOI: 10.1016/j.jcrs.2007.05.025OAI: oai:DiVA.org:liu-48833DiVA, id: diva2:269729
Available from: 2009-10-11 Created: 2009-10-11 Last updated: 2017-12-12Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Johansson, BjörnSundelin, Staffan

Search in DiVA

By author/editor
Johansson, BjörnSundelin, Staffan
By organisation
Faculty of Health SciencesOphthalmologyDepartment of Ophthalmology UHL/MH
In the same journal
Journal of cataract and refractive surgery
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 101 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf