liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Approved IFCC recommendation on reporting results for blood glucose
Instrumentation Laboratory, Lexington, MA, United States.
Hartford Hospital, Hartford, CT, United States.
Herlev Hospital, Herlev, Denmark, Department of Clinical Biochemistry, Herlev Hospital, 2730 Herlev, Denmark.
Wadsworth Center, Albany, NY, United States.
Show others and affiliations
2006 (English)In: Clinical Chemistry and Laboratory Medicine, ISSN 1434-6621, E-ISSN 1437-4331, Vol. 44, no 12, p. 1486-1490Article in journal (Refereed) Published
Abstract [en]

In current clinical practice, plasma and blood glucose are used interchangeably with a consequent risk of clinical misinterpretation. In human blood, glucose is distributed, like water, between erythrocytes and plasma. The molality of glucose (amount of glucose per unit water mass) is the same throughout the sample, but the concentration is higher in plasma, because the concentration of water and therefore glucose is higher in plasma than in erythrocytes. Different devices for the measurement of glucose may detect and report fundamentally different quantities. Different water concentrations in the calibrator, plasma, and erythrocyte fluid can explain some of the differences. Results for glucose measurements depend on the sample type and on whether the method requires sample dilution or uses biosensors in undiluted samples. If the results are mixed up or used indiscriminately, the differences may exceed the maximum allowable error for glucose determinations for diagnosing and monitoring diabetes mellitus, thus complicating patient treatment. The goal of the International Federation of Clinical Chemistry and Laboratory Medicine, Scientific Division, Working Group on Selective Electrodes and Point of Care Testing (IFCC-SD-WG-SEPOCT) is to reach a global consensus on reporting results. The document recommends reporting the concentration of glucose in plasma (in the unit mmol/L), irrespective of sample type or measurement technique. A constant factor of 1.11 is used to convert concentration in whole blood to the equivalent concentration in plasma. The conversion will provide harmonized results, facilitating the classification and care of patients and leading to fewer therapeutic misjudgments. © 2006 by Walter de Gruyter.

Place, publisher, year, edition, pages
2006. Vol. 44, no 12, p. 1486-1490
Keywords [en]
Activity, Biosensors, Glucose oxidase, Hematocrit, Plasma vs. whole blood, Standardization, Water concentration
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:liu:diva-50060DOI: 10.1515/CCLM.2006.275OAI: oai:DiVA.org:liu-50060DiVA, id: diva2:270956
Available from: 2009-10-11 Created: 2009-10-11 Last updated: 2017-12-12

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Larsson, Lasse

Search in DiVA

By author/editor
Larsson, Lasse
By organisation
Faculty of Health SciencesClinical Chemistry
In the same journal
Clinical Chemistry and Laboratory Medicine
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 156 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf