Adaptive spatio-temporal filtering of multichannel surface EMG signals
Linköping University, Faculty of Health Sciences. Linköping University, Department of Clinical and Experimental Medicine, Rehabilitation Medicine .
Centre for Biomedical Engineering and Physics, Umeå University, Umeå, Sweden, Centre of Biostochastics, Swedish University of Agricultural Sciences, Umeå, Sweden.
Department of Biomedical Engineering and Informatics, University Hospital, 901 85 Umeå, Sweden, Centre for Biomedical Engineering and Physics, Umeå University, Umeå, Sweden.
2006 (English)In: Medical and Biological Engineering and Computing, ISSN 0140-0118, Vol. 44, no 3, 209-215 p.Article in journal (Refereed) Published
Abstract [en]

A motor unit (MU) is defined as an anterior horn cell, its axon, and the muscle fibres innervated by the motor neuron. A surface electromyogram (EMG) is a superposition of many different MU action potentials (MUAPs) generated by active MUs. The objectives of this study were to introduce a new adaptive spatio-temporal filter, here called maximum kurtosis filter (MKF), and to compare it with existing filters, on its performance to detect a single MUAP train from multichannel surface EMG signals. The MKF adaptively chooses the filter coefficients by maximising the kurtosis of the output. The proposed method was compared with five commonly used spatial filters, the weighted low-pass differential filter (WLPD) and the marginal distribution of a continuous wavelet transform. The performance was evaluated using simulated EMG signals. In addition, results from a multichannel surface EMG measurement fro from a subject who had been previously exposed to radiation due to cancer were used to demonstrate an application of the method. With five time lags of the MKF, the sensitivity was 98.7% and the highest sensitivity of the traditional filters was 86.8%, which was obtained with the WLPD. The positive predictivities of these filters were 87.4 and 80.4%, respectively. Results from simulations showed that the proposed spatio-temporal filtration technique significantly improved performance as compared with existing filters, and the sensitivity and the positive predictivity increased with an increase in number of time lags in the filter. © International Federation for Medical and Biological Engineering 2006.

Place, publisher, year, edition, pages
2006. Vol. 44, no 3, 209-215 p.
Keyword [en]
Electromyography, EMG, Kurtosis, Multichannel, Spatio-temporal filter
National Category
Medical and Health Sciences
URN: urn:nbn:se:liu:diva-50291DOI: 10.1007/s11517-006-0029-1OAI: diva2:271187
Available from: 2009-10-11 Created: 2009-10-11 Last updated: 2011-01-11

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Östlund, Nils
By organisation
Faculty of Health SciencesRehabilitation Medicine
In the same journal
Medical and Biological Engineering and Computing
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 17 hits
ReferencesLink to record
Permanent link

Direct link