Energianalys av tryckluftsystem: så kan Billerud Skärblacka AB spara energi på tryckluft
Linköping University, Department of Management and Engineering, Fluid and Mechanical Engineering Systems .
Linköping University, Department of Management and Engineering, Fluid and Mechanical Engineering Systems .
2009 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

Compressed air is a low efficiency media, and is thus very expensive to produce. This thesis work began by mind mapping how to create savings on the compressed air system at Billerud Skärblacka AB. Certain issues have been chosen for further studies.

In order to identify the consumption of compressed air at PM 8 and 9, several measurements were made. At PM 8 there were not found any pressure drop, only large pressure variations for short periods of time. The causes of these pressure variations were not established. At PM 9 a registered pressure drop of around 1 bar was found. The cause of the pressure drop at PM9 was not found. A solution for the pressure drop was presented, which also could give an opportunity to reduce the nominal pressure in the compressed air system. An idea for improvement of the compressed air system structure has also been presented.

A search for leakages on the compressed air system was carried out both at PM 8 and PM 9. Leakages at PM8 seem to be lower than at PM9. The search for leakages pointed out that those leakages on the compressed air system reduces the efficiency of the compressed air system.

There are some large scale consumers of compressed air at Billerud, for example one function at PM8 and the cleaning function of timber trucks. One idea for reducing electrical consumption is to replace compressed air with a high pressure fan at PM8. In the report more suggestions for saving electrical energy regarding the other large scale consumers are presented.

Place, publisher, year, edition, pages
2009. , 48 p.
Keyword [sv]
Energi, Pneumatik
National Category
Fluid Mechanics and Acoustics
Identifiers
URN: urn:nbn:se:liu:diva-54234ISRN: LIU-IEI-TEK-G--09/00151--SEOAI: oai:DiVA.org:liu-54234DiVA: diva2:303078
Presentation
2009-12-11, MASS, Linköpings universitet, Linköping, 13:15 (English)
Uppsok
Technology
Supervisors
Examiners
Available from: 2010-03-11 Created: 2010-03-04 Last updated: 2010-03-30Bibliographically approved

Open Access in DiVA

fulltext(1339 kB)1497 downloads
File information
File name FULLTEXT02.pdfFile size 1339 kBChecksum SHA-512
035cf28ed1efdeae4fc09bad9d996f589163ef8970f33692fe1b26ecbb2f397cab7cd3ae42e2da2758e95ff858295c726dd784609a0b68c9b76528dbd63a5db7
Type fulltextMimetype application/pdf

By organisation
Fluid and Mechanical Engineering Systems
Fluid Mechanics and Acoustics

Search outside of DiVA

GoogleGoogle Scholar
Total: 1497 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 556 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf