Implementation of unsharpness and noise into the model of the imaging system: Applications to chest and lumbar spine screen-film radiography
Linköping University, Department of Medicine and Care, Radio Physics. Linköping University, Faculty of Health Sciences. Östergötlands Läns Landsting, Centre of Surgery and Oncology, Department of Radiation Physics.ORCID iD: 0000-0003-3352-8330
Joint Department of Physics, The Royal Marsden NHS Trust, UK.
Linköping University, Department of Medicine and Care, Radio Physics. Linköping University, Faculty of Health Sciences. Östergötlands Läns Landsting, Centre of Surgery and Oncology, Department of Radiation Physics.ORCID iD: 0000-0003-0209-498X
1999 (English)Report (Other academic)
Abstract [en]

A model of the complete x-ray imaging system including the patient is a powerful tool for imaging system analysis and the optimisation of image quality and patient dose. It allows flexible variation of the system components (i.e. x-ray source, antiscatter device and image detector) and study of their effect on image quality and patient risk. Our group has developed, validated and calibrated a Monte Carlo model of the complete imaging system for chest and lumbar spine examination including voxalised human male anatomy. The Monte Carlo program calculates the contrast and signal-to-noise ratio (SNR) of various contrasting details within the voxel phantom. Important details in the images have been selected by consulting radiologist and the EU document of image quality criteria. The entrance surface dose without back-scatter and the effective dose are used as measures of patient radiation risk.

The contrasts of the details are derived initially from Monte Carlo estimates of the energy imparted per unit area to the image detector beside and behind the detail. However, this ignores the effects of unsharpness in the imaging chain (such as screen-film, geometric and motion unsharpness) and the influence on contrast of the film characteristic curve. In the Monte Carlo program, SNR is calculated assuming that the noise arises from the random fluctuations in the energy imparted per unit area to the image detector only. However, other noise sources also contribute to the total noise, such as screen and film noise. Hence the model of the imaging system needs to be further developed to take these effects into account. The methods used to extend the model are described below together with illustrations of their effect on the difference in optical density, DOD, and SNR in chest and lumbar spine imaging.

Place, publisher, year, edition, pages
Linköping: Linköping University Electronic Press , 1999. , 50 p.
Series
Report / Department of Radiology, Linköping University, 1998-, 90
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:liu:diva-57831ISRN: LIU-RAD-R-090OAI: oai:DiVA.org:liu-57831DiVA: diva2:327957
Available from: 2010-07-01 Created: 2010-07-01 Last updated: 2015-03-20Bibliographically approved

Open Access in DiVA

Implementation of unsharpness and noise into the model of the imaging system : Applications to chest and lumbar spine screen-film radiography(422 kB)583 downloads
File information
File name FULLTEXT01.pdfFile size 422 kBChecksum SHA-512
1db8847ec32a1d57a8cc6bead5d200a1f85a4f18ec980c426623fead6a9bf6401d0c5178aaee9c35083f1811dd55ce2c6ea896ef2e16a493a68ef15ea2e54038
Type fulltextMimetype application/pdf

Authority records BETA

Sandborg, MichaelAlm Carlsson, Gudrun

Search in DiVA

By author/editor
Sandborg, MichaelAlm Carlsson, Gudrun
By organisation
Radio PhysicsFaculty of Health SciencesDepartment of Radiation Physics
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 583 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 77 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf