Validation of Voxman Monte Carlo code and calibration for digital systems
Linköping University, Department of Medicine and Care, Radio Physics. Linköping University, Faculty of Health Sciences.
Linköping University, Department of Medicine and Care, Radio Physics. Linköping University, Faculty of Health Sciences. Östergötlands Läns Landsting, Centre of Surgery and Oncology, Department of Radiation Physics.ORCID iD: 0000-0003-3352-8330
Linköping University, Department of Medicine and Care, Radio Physics. Linköping University, Faculty of Health Sciences. Östergötlands Läns Landsting, Centre of Surgery and Oncology, Department of Radiation Physics.ORCID iD: 0000-0003-0209-498X
2003 (English)Report (Other academic)
Abstract [en]

The objective of this work was to test the Monte Carlo model ‘Voxman’ against measurements on x-ray systems in the clinic. X-ray transmission experiments are performed to test of the accuracy of the Monte Carlo photon transport. Experiments were also performed with an image plate (CR) system in the clinic to compare the measured pixel values with calculated pixel values. Measurements were also performed with the automatic exposure control (AEC) chambers used in Linköping and Motala. The purpose for those measurements was to choose a normalisation of the entrance surface dose.

Place, publisher, year, edition, pages
Linköping: Linköping University Electronic Press , 2003. , 16 p.
Series
Report / Department of Radiology, Linköping University, 1998-, 95
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:liu:diva-57858ISRN: LIU-RAD-R-095OAI: oai:DiVA.org:liu-57858DiVA: diva2:328147
Available from: 2010-07-01 Created: 2010-07-01 Last updated: 2015-03-20Bibliographically approved

Open Access in DiVA

Validation of Voxman Monte Carlo code and calibration for digital systems(140 kB)387 downloads
File information
File name FULLTEXT01.pdfFile size 140 kBChecksum SHA-512
b1d113194663e2a7b038dd375c627484f3c5eabf17dc97ad2389f02770dbcb0319e40a875f87c33ec452e39a6799d0536d054247baeabd499407b8fd1c57623c
Type fulltextMimetype application/pdf

Authority records BETA

Ullman, GustavSandborg, MichaelAlm Carlsson, Gudrun

Search in DiVA

By author/editor
Ullman, GustavSandborg, MichaelAlm Carlsson, Gudrun
By organisation
Radio PhysicsFaculty of Health SciencesDepartment of Radiation Physics
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 387 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 62 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf