liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Comparison of clinical and physical measures of image quality in chest PA and pelvis AP views at varying tube voltages
Linköping University, Department of Medicine and Care, Radio Physics. Linköping University, Faculty of Health Sciences.
Linköping University, Department of Medicine and Care, Radio Physics. Linköping University, Faculty of Health Sciences. Östergötlands Läns Landsting, Centre of Surgery and Oncology, Department of Radiation Physics.ORCID iD: 0000-0003-3352-8330
Department of Radiation Physics, Malmö University Hospital, Sweden.
Department of Physics, The Royal Marsden NHS Trust, UK.
Show others and affiliations
2004 (English)Report (Other academic)
Abstract [en]

Image quality in digital chest PA and pelvis AP was assessed using two different methods; one based on observations of images of an anthropomorphic phantom, one based on computer modelling using an anthropomorphic voxel phantom. The tube voltage was varied within a broad range (50-150 kV), including those values typically used with screen-film radiography. The tube charge was altered so that approximately the same effective dose was achieved in the modelled patient (anthropomorphic phantom). Two x-ray units were employed using a digital image detector (computed radiography, CR, system) with standard tube filtration and anti-scatter device. Clinical image quality was assessed by a group of radiologists using a visual grading analysis (VGA) technique based on the revised CEC image criteria. Physical image quality was derived from the computer model in terms of the signal-to-noise ratio, SNR for fixed effective dose in the voxel phantom. The computer model uses Monte Carlo simulations of the patient and complete imaging system. Both the VGAS (visual grading analysis score) and SNR increase with decreasing tube voltage in both chest PA and pelvis AP examinations, indicating superior performance if lower tube voltages than used today are employed in digital radiology. A positive correlation between clinical and physical measures of image quality was found. The pros and cons of using lower tube voltages with CR digital radiography than typically used in analogue screen-film radiography are discussed as well as the relevance of using VGAS and quantum noise SNR as measures of image quality.

Place, publisher, year, edition, pages
Linköping: Linköping University Electronic Press , 2004. , 11 p.
Series
Report / Department of Radiology, Linköping University, 1998-, 98
Keyword [en]
image quality, effective dose, tube voltage, visual grading analysis, signal-to-noise ratio, chest radiography, pelvis radiography, computed radiography
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:liu:diva-57862ISRN: LIU-RAD-R-098OAI: oai:DiVA.org:liu-57862DiVA: diva2:328154
Available from: 2010-07-01 Created: 2010-07-01 Last updated: 2015-03-20Bibliographically approved

Open Access in DiVA

Comparison of clinical and physical measures of image quality in chest PA and pelvis AP views at varying tube voltages(296 kB)1412 downloads
File information
File name FULLTEXT01.pdfFile size 296 kBChecksum SHA-512
3ef017e6f6533d61459113cc8d9b2c7ba935436003249823f73d83b2313813992381f3c5f680390b906edd8ad39b917d538b96601f4d71256d5e64ca431ef4e9
Type fulltextMimetype application/pdf

Authority records BETA

Ullman, GustavSandborg, MichaelAlm Carlsson, Gudrun

Search in DiVA

By author/editor
Ullman, GustavSandborg, MichaelAlm Carlsson, Gudrun
By organisation
Radio PhysicsFaculty of Health SciencesDepartment of Radiation Physics
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 1412 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 219 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf