Treatment of presumed acute cardiogenic pulmonary oedema in an ambulance system by nurses using Boussignac continuous positive airway pressure.
Show others and affiliations
2009 (English)In: Emergency Medicine Journal, ISSN 1472-0205, E-ISSN 1472-0213, Vol. 26, no 2, 141-4 p.Article in journal (Refereed) Published
Abstract [en]

BACKGROUND: Early initiation of continuous positive airway pressure (CPAP) applied by face mask benefits patients with acute cardiogenic pulmonary oedema (ACPE). The simple disposable Boussignac CPAP (BCPAP) has been used in ambulances by physicians. In the Netherlands, ambulances are manned by nurses and not physicians. It was hypothesised that ambulance nurses are able to identify patients with ACPE and can successfully apply BCPAP. A prospective case series of patients with presumed ACPE treated with BCPAP by ambulance nurses is described. METHODS: After training of ambulance nurses, all 33 ambulances in the region were equipped with BCPAP. ACPE was diagnosed on clinical signs and pulse oximetry saturation (Spo(2)) <95%. BCPAP (5 cm H(2)O, Fio(2)>80%) was generated with an oxygen flow of 15 l/min. The physiological responses, experiences and clinical outcomes of the patients were collected from ambulance and hospital records, and ambulance nurses and patients received a questionnaire. RESULTS: From March to December 2006, 32 patients (age range 61-94 years) received BCPAP during transport to six different regional hospitals. In 26 patients (81%) a diagnosis of ACPE was confirmed. With BCPAP, median (IQR) Spo(2) increased from 79% (69-94%) to 96% (89-98%) within 20 min. The median (IQR) duration of BCPAP treatment was 26 min (21-32). The patients had no negative recollections of the treatment. Ambulance personnel were satisfied with the BCPAP therapy. CONCLUSION: When applied by ambulance nurses, BCPAP was feasible and effective in improving oxygen saturation in patients with ACPE. Although survival benefit can only be demonstrated by further research, it is considered that BCPAP can be implemented in all ambulances in the Netherlands.

Place, publisher, year, edition, pages
2009. Vol. 26, no 2, 141-4 p.
URN: urn:nbn:se:liu:diva-62426DOI: 10.1136/emj.2007.055095PubMedID: 19164632OAI: diva2:373230
Available from: 2010-11-30 Created: 2010-11-30 Last updated: 2010-11-30

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed
In the same journal
Emergency Medicine Journal

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 16 hits
ReferencesLink to record
Permanent link

Direct link