Novel hexacyanoferrate(III) modified graphite disc electrodes and their application in enzyme electrodes .1.
; .
Cranfield University, UK.ORCID iD: 0000-0002-1815-9699
1997 (English)In: Biosensors & bioelectronics, ISSN 0956-5663, E-ISSN 1873-4235, Vol. 12, no 1Article in journal (Refereed) Published
Abstract [en]

We report a novel procedure for the electrochemical modification of graphite disc electrodes with potassium hexacyanoferrate(III) using cyclic voltammetry. Cyclic voltammograms of the modified electrodes in 0.1 M potassium chloride showed two redox couples, at 0.22 and 0.148V and at 0.923 and 0.798 V. These redox potentials correspond to those cited for Prussian blue type films. These modified electrodes exhibited excellent stability during repeated potential cycling in 0.1 M potassium chloride with no difference in peak heights between the second and thirtieth scans. We used glucose oxidase as the model enzyme to investigate application of these novel modified graphite disc electrodes in the development of biosensors. The resulting glucose sensors exhibited a response to glucose at potentials as low as 450 mV vs. saturated calomel electrode with a linear range up to 1.5 mM glucose and sensitivity of 50 +/- 10 nA mM(-1) cm(-2) (geometric area). The modified graphite disc electrodes displayed an electrocatalytic effect on hydrogen peroxide with sensitivity of 0.70 mu A mM(-1) cm(-2) (geometric area). The effect of ascorbic acid, 4-acetamidophenol and uric acid, common interferents found in blood, is also reported. (C) 1996 Published by Elsevier Science Limited

Place, publisher, year, edition, pages
Elsevier Science B.V., Amsterdam. , 1997. Vol. 12, no 1
Keyword [en]
Prussian Blue; hexacyanoferrate(III)); graphite electrodes; biosensor; glucose; hydrogen peroxide
National Category
Engineering and Technology
URN: urn:nbn:se:liu:diva-65265ISI: A1997VX80600001OAI: diva2:394969
Available from: 2011-02-04 Created: 2011-02-04 Last updated: 2013-10-04

Open Access in DiVA

No full text

Search in DiVA

By author/editor
Turner, APF
In the same journal
Biosensors & bioelectronics
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 28 hits
ReferencesLink to record
Permanent link

Direct link