Swedish population data and concordance for the kits PowerPlexÒ ESX 16 System, PowerPlexÒ ESI 16 System, AmpFlSTRÒ NGMTM, AmpFlSTRÒ SGM PlusTM and Investigator ESSplex
Swedish National Laboratory of Forensic Science (SKL), Linköping, Sweden.
Swedish National Laboratory of Forensic Science (SKL), Linköping, Sweden.
Swedish National Laboratory of Forensic Science (SKL), Linköping, Sweden.
Linköping University, Department of Physics, Chemistry and Biology, Molecular genetics. Linköping University, The Institute of Technology.
2011 (English)In: Forensic Science International: Genetics, ISSN 1872-4973, Vol. 5, no 3, e89-e92 p.Article in journal, Letter (Other academic) Published
Abstract [en]

The European Standard Set of loci (ESS) has been extended with five additional short tandem repeat (STR) loci following the recommendations of the European Network of Forensic Science Institutes (ENFSI) and the European DNA Profiling Group (EDNAP) to increase the number of loci routinely used by the European forensic community. Subsequently, a new extended Swedish population database, based on 425 individuals, has been assembled using the new STR multiplex kits commercially available.

Allele frequencies and statistical parameters of forensic interest for 15 autosomal STR loci (D3S1358, TH01, D21S11, D18S51, D10S1248, D1S1656, D2S1338, D16S539, D22S1045, vWA, D8S1179, FGA, D2S441, D12S391 and D19S433) were obtained from the analysis of the PowerPlex® ESX 16 System kit (Promega Corporation, USA). According to the data no evidence of deviations from Hardy–Weinberg equilibrium was found. The observed heterozygosity varies between 0.755 (TH01) and 0.892 (D1S1656). The power of discrimination was smallest for D22S1045 (0.869) and largest for D1S1656 (0.982) while the power of exclusion was smallest for TH01 (0.518) and largest for D1S1656 (0.778).

A concordance study was performed on the five amplification systems: PowerPlex® ESX 16 System, PowerPlex® ESI 16 System (Promega Corporation, USA), AmpFlSTR® NGM™, AmpFlSTR® SGM Plus™ (Applied Biosystems, USA) and Investigator ESSplex (Qiagen, Germany) to reveal null alleles and other divergences between the kits. For the 425 DNA profiles included, AmpFlSTR® NGM™ revealed two null alleles, AmpFlSTR® SGM Plus™ revealed one, and Investigator ESSplex revealed a micro-variant, while the rest of the alleles showed full concordance between the kits tested.

Place, publisher, year, edition, pages
Clare, Irland: Elsevier, 2011. Vol. 5, no 3, e89-e92 p.
National Category
Natural Sciences
URN: urn:nbn:se:liu:diva-67589DOI: 10.1016/j.fsigen.2010.11.005ISI: 000289193200010OAI: diva2:411443
Available from: 2011-04-18 Created: 2011-04-18 Last updated: 2014-03-25Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Ansell, Ricky
By organisation
Molecular geneticsThe Institute of Technology
In the same journal
Forensic Science International: Genetics
Natural Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 55 hits
ReferencesLink to record
Permanent link

Direct link