liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Experimental verification of a model for estimating the particle size dependence of extrinsic efficiency of radioluminescent layers
Linköping University, Department of Medical and Health Sciences, Radiation Physics. Linköping University, Faculty of Health Sciences.
Linköping University, Department of Medical and Health Sciences, Radiation Physics. Linköping University, Faculty of Health Sciences. Östergötlands Läns Landsting, Centre for Surgery, Orthopaedics and Cancer Treatment, Department of Radiation Physics UHL.ORCID iD: 0000-0003-3352-8330
Linköping University, Department of Medical and Health Sciences, Radiation Physics. Linköping University, Faculty of Health Sciences.
(English)Manuscript (preprint) (Other academic)
Abstract [en]

The extrinsic (absolute) efficiency of a phosphor is expressed as the ratio of light energy emitted per unit area at the phosphor surface to incident x-ray energy fluence. Several studies on polycrystalline phosphor materials show that the optical parameters of a specific phosphor may vary within a wide range of values. The aim of this work was to verify a previously published model where all optical parameters were replaced with a single parameter, the light extinction factor ξ. The varying extrinsic efficiency for an extended range of particle sizes and layer thicknesses are calculated from the input parameters: the intrinsic efficiency η, the mean particle size of the phosphor, the thickness of the layer, the light extinction factor and the calculated energy imparted to the layer. The X-ray spectrum was simulated utilising the SpekCalc software (Poludniowski et al 2009). In this work, calculations of the energy imparted to in-house manufactured Gd2O2S:Tb screens, were also compared to calculations improved making use of Monte Carlo simulations (software PENELOPE (Baro et al 1995)). KAP (kerma area product) -rate-values were noted and the corresponding luminance measured and compared to calculated values. The deviations were ±14 % within the studied range.

National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:liu:diva-70538OAI: oai:DiVA.org:liu-70538DiVA: diva2:440154
Available from: 2011-09-12 Created: 2011-09-12 Last updated: 2013-09-03Bibliographically approved
In thesis
1. Radioluminescence: A simple model for fluorescent layers
Open this publication in new window or tab >>Radioluminescence: A simple model for fluorescent layers
2011 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

The aim of this thesis is to present a simple model for the radiation to light conversion processes in fluorescent layers as an aid in future developments and applications. Optimisation between sensitivity and spatial resolution for fluorescent layers in digital radiology is a delicate task where the extrinsic efficiency for various phosphors needs to be established for varying parameters. The extrinsic efficiency of a fluorescent layer can be expressed as the ratio of the light energy per unit area at the screen surface to the incident xray energy fluence. Particle size is a critical factor in determining the value of the extrinsic efficiency, but in most models it is not treated as an independent variable. Based on the definition of a light extinction factor (ξ), a model is proposed such that, knowing the intrinsic efficiency η, the particle size and the thickness of a certain make of screen, the extrinsic efficiency can be calculated for an extended range of particle sizes and / or screen thicknesses. The light extinction factor ξ is an optical parameter determined from experimental data on extrinsic efficiency. The proposed model is compared to established methods. Further experiments have confirmed the validity of the model. Monte-Carlo simulations have been utilised to refine the calculations of energy imparted to the phosphor by taking into account the escape of scattered and K-radiation generated in the screen and interface effects at the surfaces. The luminance was measured for a set of in-house manufactured screens of varying thicknesses and particle sizes. Utilising the proposed model, the corresponding calculated values deviated ± 14 %.within the studied range.

Place, publisher, year, edition, pages
Linköping: Linköping University Electronic Press, 2011. 36 p.
Series
Linköping Studies in Health Sciences. Thesis, ISSN 1100-6013 ; 117
Keyword
Extrinsic efficiency, extinction factor, radioluminescence, modelling, Monte Carlo, optical attenuation, optimisation, particle size, phosphor, scintillator
National Category
Medical and Health Sciences
Identifiers
urn:nbn:se:liu:diva-70539 (URN)978-91-7393-098-7 (ISBN)
Supervisors
Available from: 2011-09-12 Created: 2011-09-12 Last updated: 2013-09-03Bibliographically approved

Open Access in DiVA

No full text

Authority records BETA

Sandborg, Michael

Search in DiVA

By author/editor
Sandborg, Michael
By organisation
Radiation PhysicsFaculty of Health SciencesDepartment of Radiation Physics UHL
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 92 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf