A novel optical biosensor format for the detection of clinically relevant TP53 mutations
Cranfield University, UK.
Hunan Normal University, PR China.
Università delgi Studi di Firenze, Italy.
Cranfield University, UK.ORCID iD: 0000-0002-1815-9699
Show others and affiliations
2005 (English)In: Biosensors & bioelectronics, ISSN 0956-5663, E-ISSN 1873-4235, Vol. 20, no 11, 2310-2313 p.Article in journal (Refereed) Published
Abstract [en]

The TP53 gene has been the subject of intense research since the realisation that inactivation of this gene is common to most cancer types. Numerous publications have linked TP53 mutations in general or at specific locations to patient prognosis and therapy response. The findings of many studies using general approaches such as immunohistochemistry or sequencing are contradictory. However, the detection of specific mutations, especially those occurring in the structurally important L2 and L3 zinc binding domains, which are the most common sites of TP53 mutations, have been linked to patient prognosis and more strongly to radiotherapy and chemotherapy resistance in several major cancers. In this study, the TI-SPR-1 surface plasmon resonance system and Texas Instruments Spreeta (TM) chips were used to develop a DNA biosensor based on thiolated probes complementary to these domains. The sensors were able to detect these mutations in both oligonucleotides and PCR products with normal and mutant TP53 DNA, but the difference in hybridisation signal was small. Preliminary experiments to enhance the signal using Escherichia coli mismatch repair proteins, MutS and single strand binding protein were carried out. It was found that MutS was unable to bind to mismatch oligonucleotides, but single strand binding protein was able to bind to single stranded probes, which had not hybridised to the target, resulting in a three-fold increase in the sensitivity of the biosensor. While further work needs to be carried out to optimise the system, these preliminary experiments indicate that the TI-SPR-1 can be used for the detection of clinically relevant mutations in the TP53 gene and that the sensitivity can be increased significantly using single strand binding protein. This system has a number of advantages over current mutation detection technologies, including lower cost, ease of sensor preparation and measurement procedures, technical simplicity and increased speed due to the lack of need for gel electrophoresis.

Place, publisher, year, edition, pages
Elsevier , 2005. Vol. 20, no 11, 2310-2313 p.
Keyword [en]
TP53 mutation; p53 mutation; DNA biosensor surface plasmon resonance; mutation detection; optical biosensor
National Category
Engineering and Technology
URN: urn:nbn:se:liu:diva-70600DOI: 10.1016/j.bios.2004.11.020ISI: 000228827000017OAI: diva2:440904
Available from: 2011-09-14 Created: 2011-09-14 Last updated: 2013-10-04

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Turner, A P F
In the same journal
Biosensors & bioelectronics
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 23 hits
ReferencesLink to record
Permanent link

Direct link