Theoretical simulation of oxygen tension measurement in tissues using a microelectrode: I. The response function of the electrode
Umeå University.ORCID iD: 0000-0002-7101-240X
Umeå University.
Umeå University.ORCID iD: 0000-0001-8171-2541
Umeå University.
2001 (English)In: Physiological Measurement, ISSN 0967-3334, E-ISSN 1361-6579, Vol. 22, no 4, 713-725 p.Article in journal (Refereed) Published
Abstract [en]

The aim of this article is to determine the correlation between the actual oxygen distribution in tissues and the distribution of oxygen measured by microelectrodes. This correlation is determined by the response function of the electrode, which depends on the oxygen consumed by the electrode. In tissue it is necessary to consider the gradients resulting from cellular respiration. A computer program has been used to simulate the vascular structure of various tissues and also the measurements of oxygen tension using a polarographic electrode. The electrode absorption process is described using a theoretical model. The gradient of oxygen in tissue is described by a mathematical model that takes into consideration both diffusion and cellular consumption of oxygen. We have compared the results obtained using the response function of the electrode and some simplifications of it. The results of these comparisons show that there are some differences in the 'observed' distributions of the oxygen tension in tissues predicted using different formulae for the electrode response function. Also, there are considerable differences between the input oxygen distribution and the measured values in all cases. All the results of the simulations of the oxygen tension 'observed' by a 12 microm polarographic electrode, using different response functions of the electrode, show that the electrode averages the values from many cells. Care should be taken in using a simplification for the response function of the electrode, especially if the results are going to be used as input values in modelling the tumour response to new treatments and/or as a basis of selecting patients for treatments. A computer simulation of measurement of oxygen tensions in regions of steep pO2 gradients shows that extremely high and extremely low pO2 values will not be detected.

Place, publisher, year, edition, pages
2001. Vol. 22, no 4, 713-725 p.
National Category
Cancer and Oncology
URN: urn:nbn:se:liu:diva-72002DOI: 10.1088/0967-3334/22/4/306PubMedID: 11761078OAI: diva2:455882
Available from: 2011-11-11 Created: 2011-11-11 Last updated: 2015-03-07

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Toma-Daşu, IulianaDaşu, Alexandru
In the same journal
Physiological Measurement
Cancer and Oncology

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 22 hits
ReferencesLink to record
Permanent link

Direct link