liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Development of a harmonised method for the profiling of amphetamines : III. Development of the gas chromatographic method
Swedish National Laboratory of Forensic Science.
National Bureau of Investigation, Finland.
University of Lausanne.
University of Strathclyde, Glasgow.
Show others and affiliations
2007 (English)In: Forensic Science International, ISSN 0379-0738, E-ISSN 1872-6283, Vol. 169, no 1, 50-63 p.Article in journal (Refereed) Published
Abstract [en]

This study focused on gas chromatographic analysis of target compounds found in illicit amphetamine synthesised by the Leuckart reaction, reductive amination of benzyl methyl ketone, and the nitrostyrene route. The analytical method was investigated and optimised with respect to introduction of amphetamine samples into the gas chromatograph and separation and detection of the target substances. Sample introduction using split and splitless injection was tested at different injector temperatures, and their ability to transfer the target compounds to the GC column was evaluated using cold on column injection as a reference. Taking the results from both techniques into consideration a temperature of 250 °C was considered to be the best compromise. The most efficient separation was achieved with a DB-35MS capillary column (35% diphenyl 65% dimethyl silicone; 30 m × 0.25 mm, df 0.25 μm) and an oven temperature program that started at 90 °C (1 min) and was increased by 8 °C/min to 300 °C (10 min). Reproducibility, repeatability, linearity, and limits of determination for the flame ionisation detector (FID), nitrogen phosphorous detector (NPD), and mass spectrometry (MS) in scan mode and selected ion monitoring (SIM) mode were evaluated. In addition, selectivity was studied applying FID and MS in both scan and SIM mode. It was found that reproducibility, repeatability, and limits of determination were similar for FID, NPD, and MS in scan mode. Moreover, the linearity was better when applying FID or NPD whereas the selectivity was better when utilising the MS. Finally, the introduction of target compounds to the GC column when applying injection volumes of 0.2 μl, 1 μl, 2 μl, and 4 μl with splitless injection respectively 1 μl with split injection (split ratio, 1:40) were compared. It was demonstrated that splitless injections of 1 μl, 2 μl, and 4 μl could be employed in the developed method, while split injection and splitless injections of 0.2 μl should be avoided.

Place, publisher, year, edition, pages
Elsevier , 2007. Vol. 169, no 1, 50-63 p.
Keyword [en]
Amphetamine; Impurities; Profiling; Optimisation; Separation; Gas chromatography–mass spectrometry
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:liu:diva-72288DOI: 10.1016/j.forsciint.2006.10.018ISI: 247113600007OAI: oai:DiVA.org:liu-72288DiVA: diva2:459017
Available from: 2011-11-24 Created: 2011-11-24 Last updated: 2017-12-08

Open Access in DiVA

No full text

Other links

Publisher's full text

Authority records BETA

Dahlén, Johan

Search in DiVA

By author/editor
Dahlén, Johan
In the same journal
Forensic Science International
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 48 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf