Development of a method for optical monitoring of creatinine in the spent dialysate
Tallinn University of Technology, Estonia.
Linköping University, Department of Medical and Health Sciences, Nursing Science. Linköping University, Faculty of Health Sciences. Östergötlands Läns Landsting, Heart and Medicine Center, Department of Nephrology.
Tallinn University of Technology, Estonia.
Tallinn University of Technology, Estonia.
Show others and affiliations
2011 (English)In: Estonian Journal of Engineering, ISSN 1736-6038, Vol. 17, no 2, 140-150 p.Article in journal (Refereed) Published
Abstract [en]

The aim of the study was to develop a method suitable for the estimation of the amount of creatinine, removed during dialysis through UV-absorbance. Sixteen uremic patients, seven females and nine males, on chronic thrice-weekly hemodialysis were included in the study. Double-beam spectrophotometer was used for the determination of UV-absorbance in the collected spent dialysate samples. Due to differences in independent variables, two multi-wavelength models (m1 and m2) were developed using stepwise regression, utilizing creatinine values from the laboratory as the dependent parameter. The coefficient of determination, R2 was 0.8690 for the first and 0.9103 for the second model. The systematic error, estimated as BIAS, was zero for both models compared to the creatinine values from the laboratory. The standard errors were 10.06 µmol/l and 15.24 µmol/l for m1 and m2, respectively. The average reduction ratio (RR) from creatinine blood values was 59.8 ± 5.4% (N = 50), average RR from m1 was 63.7 ± 7.3% (N = 50) and average RR from m2 was 64.8 ± 6.4% (N = 48). In summary, the amount of creatinine removed as well as the reduction ratio of creatinine during dialysis can be estimated with UV-absorbance technique.

Place, publisher, year, edition, pages
2011. Vol. 17, no 2, 140-150 p.
Keyword [en]
hemodialysis monitoring, creatinine, UV-absorption
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:liu:diva-73445DOI: 10.3176/eng.2011.2.04OAI: oai:DiVA.org:liu-73445DiVA: diva2:472467
Available from: 2012-01-03 Created: 2012-01-03 Last updated: 2017-01-03Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Authority records BETA

Uhlin, FredrikFridolin, Ivo

Search in DiVA

By author/editor
Uhlin, FredrikFridolin, Ivo
By organisation
Nursing ScienceFaculty of Health SciencesDepartment of Nephrology
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 109 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf