Radiation Dose Reduction with Sinogram Affirmed Iterative Reconstruction Technique for abdominal Computer Tomography
Department of Radiology, Massachusetts General Hospital, Boston, USA .
Linköping University, Department of Medical and Health Sciences, Radiology. Linköping University, Faculty of Health Sciences. Linköping University, Center for Medical Image Science and Visualization (CMIV). Östergötlands Läns Landsting, Center for Diagnostics, Department of Radiology in Linköping.
Linköping University, Department of Medical and Health Sciences, Radiology. Linköping University, Faculty of Health Sciences. Linköping University, Center for Medical Image Science and Visualization (CMIV). Östergötlands Läns Landsting, Center for Diagnostics, Department of Radiology in Linköping.ORCID iD: 0000-0002-4111-1693
Department of Radiology, Massachusetts General Hospital, Boston, USA .
Show others and affiliations
2012 (English)In: Journal of Computer Assisted Tomography, ISSN 0363-8715, Vol. 36, no 3, 339-346 p.Article in journal (Refereed) Published
Abstract [en]

Purpose: The objective of this study was to assess the effect of Sinogram Affirmed Iterative Reconstruction (SAFIRE) and filtered back-projection (FBP) techniques on abdominal computed tomography (CT) performed with 50% and 75% radiation dose reductions.

Methods: Twenty-four patients (mean age, 64 ± 14 years; male-female ratio, 10:14) gave informed consent for an institutional review board–approved prospective study involving acquisition of additional research images through the abdomen on 128-slice multi–detector-row CT (SOMATOM Definition Flash) at quality reference mAs of 100 (50% lower dose) and 50 (75% lower dose) over a scan length of 10 cm using combined modulation (CARE Dose 4D). Standard-of-care abdominal CT was performed at 200 quality reference mAs, with remaining parameters held constant. The 50- and 100-mAs data sets were reconstructed with FBP and at 4 SAFIRE settings (S1, S2, S3, S4). Higher number of SAFIRE settings denotes increased strength of the algorithm resulting in lower image noise. Two abdominal radiologists independently compared the FBP and SAFIRE images for lesion number, location, size and conspicuity, and visibility of small structures, image noise, and diagnostic confidence. Objective noise and Hounsfield units (HU) were measured in the liver and the descending aorta.

Results: All 43 lesions were detected on both FBP and SAFIRE images. Minor blocky, pixelated appearance of 50% and 75% reduced dose images was noted at S3 and S4 SAFIRE but not at S1 and S2 settings. Subjective noise was suboptimal in both 50% and 75% lower-dose FBP images but was deemed acceptable on all SAFIRE settings. Sinogram Affirmed Iterative Reconstruction images were deemed acceptable in all patients at 50% lower dose and in 22 of 24 patients at 75% lower dose. As compared with 75% reduced dose FBP, objective noise was lower by 22.8% (22.9/29.7), 35% (19.3/29.7), 44.3% (16.7/29.3), and 54.8% (13.4/29.7) on S1 to S4 settings, respectively (P < 0.001).

Conclusions: Sinogram Affirmed Iterative Reconstruction–enabled reconstruction provides abdominal CT images without loss in diagnostic value at 50% reduced dose and in some patients also at 75% reduced dose.

Place, publisher, year, edition, pages
USA: Lippincott Williams & Wilkins, 2012. Vol. 36, no 3, 339-346 p.
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:liu:diva-75846DOI: 10.1097/RCT.0b013e31825586c0ISI: 000304201200013OAI: oai:DiVA.org:liu-75846DiVA: diva2:509265
Available from: 2012-03-12 Created: 2012-03-12 Last updated: 2017-03-07

Open Access in DiVA

No full text

Other links

Publisher's full text

Authority records BETA

Woisetschläger, MischaDahlström, NilsLindblom, MariaQuick, PetterPersson, Anders

Search in DiVA

By author/editor
Woisetschläger, MischaDahlström, NilsLindblom, MariaQuick, PetterPersson, Anders
By organisation
RadiologyFaculty of Health SciencesCenter for Medical Image Science and Visualization (CMIV)Department of Radiology in Linköping
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 167 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf