liu.seSearch for publications in DiVA
Change search
ReferencesLink to record
Permanent link

Direct link
Rigid, complete annuloplasty rings increase anterior mitral leaflet strain in normal beating ovine heart
Stanford University School of Medicine, USA.
Stanford University School of Medicine, USA.
Stanford University School of Medicine, USA.
Stanford University School of Medicine, USA.
Show others and affiliations
2011 (English)In: Circulation, ISSN 0009-7322, E-ISSN 1524-4539, Vol. 124, S81-S96 p.Article in journal (Refereed) Published
Abstract [en]


Annuloplasty ring or band implantation during surgical mitral valve repair perturbs mitral annular dimensions, dynamics, and shape, which have been associated with changes in anterior mitral leaflet (AML) strain patterns and suboptimal long-term repair durability. We hypothesized that rigid rings with nonphysiological three-dimensional shapes, but not saddle-shaped rigid rings or flexible bands, increase AML strains.


Sheep had 23 radiopaque markers inserted: 7 along the anterior mitral annulus and 16 equally spaced on the AML. True-sized Cosgrove-Edwards flexible, partial band (n=12), rigid, complete St Jude Medical rigid saddle-shaped (n=12), Carpentier-Edwards Physio (n=12), Edwards IMR ETlogix (n=11), and Edwards GeoForm (n=12) annuloplasty rings were implanted in a releasable fashion. Under acute open-chest conditions, 4-dimensional marker coordinates were obtained using biplane videofluoroscopy along with hemodynamic parameters with the ring inserted and after release. Marker coordinates were triangulated, and the largest maximum principal AML strains were determined during isovolumetric relaxation. No relevant changes in hemodynamics occurred. Compared with the respective control state, strains increased significantly with rigid saddle-shaped annuloplasty ring, Carpentier-Edwards Physio, Edwards IMR ETlogix, and Edwards GeoForm (0.14 ± 0.05 versus 0.16 ± 0.05, P=0.024, 0.15 ± 0.03 versus 0.18 ± 0.04, P=0.020, 0.11 ± 0.05 versus 0.14 ± 0.05, P=0.042, and 0.13 ± 0.05 versus 0.16 ± 0.05, P=0.009), but not with Cosgrove-Edwards band (0.15 ± 0.05 versus 0.15 ± 0.04, P=0.973).


Regardless of three-dimensional shape, rigid, complete annuloplasty rings, but not a flexible, partial band, increased AML strains in the normal beating ovine heart. Clinical studies are needed to determine whether annuloplasty rings affect AML strains in patients, and, if so, whether ring-induced perturbations in leaflet strain states are linked to repair failure.

Place, publisher, year, edition, pages
2011. Vol. 124, S81-S96 p.
National Category
Medical and Health Sciences
URN: urn:nbn:se:liu:diva-76230DOI: 10.1161/CIRCULATIONAHA.110.011163PubMedID: 21911823OAI: diva2:513054
Available from: 2012-03-30 Created: 2012-03-30 Last updated: 2012-04-05

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed
In the same journal
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 37 hits
ReferencesLink to record
Permanent link

Direct link