Averaging level control in the presence of frequent inlet flow upsets
Linköping University, Department of Electrical Engineering, Automatic Control. Linköping University, The Institute of Technology.
2012 (English)Licentiate thesis, monograph (Other academic)
Abstract [en]

Buffer tanks are widely used within the process industry to prevent flow variations from being directly propagated throughout a plant. The capacity of the tank is used to smoothly transfer inlet flow upsets to the outlet. Ideally, the tank thus works as a low pass filter where the available tank capacity limits the achievable flow smoothing.

For infrequently occurring upsets, where the system has time to reach steady state between flow changes, the averaging level control problem has been extensively studied. After an inlet flow change, flow filtering has traditionally been obtained by letting the tank level deviate from its nominal value while slowly adapting the outlet to cancel out the flow imbalance and eventually bringing back the level to its set-point. The system is then again in steady state and ready to surge the next upset. By ensuring that the single largest upset can be handled without violating the level constraints, satisfactory flow smoothing is obtained.

In this thesis, the smoothing of frequently changing inlet flows is addressed. In this case, standard level controllers struggle to obtain acceptable flow smoothing since the system rarely is in steady state and flow upsets can thus not be treated as separate events. To obtain a control law that achieves optimal filtering while directly accounting for future upsets, the averaging level control problem was approached using robust model predictive control (MPC).

The robust MPC differs in the way it obtains flow smoothing by not returning the tank level to a fixed set-point. Instead, it lets the steady state tank level depend on the current value of the inlet flow. This insight was then used to propose a linear control structure, designed to filter frequent upsets optimally. Analyses and simulation results indicate that the proposed linear and robust MPC controller obtain flow smoothing comparable to the standard optimal averaging level controllers for infrequent upsets while handling frequent upsets considerably better.

Place, publisher, year, edition, pages
Linköping: Linköping University Electronic Press, 2012. , 103 p.
Series
Linköping Studies in Science and Technology. Thesis, ISSN 0280-7971 ; 1527
Keyword [en]
Averaging level control, PI control, Surge tanks, Optimal control, Robust MPC, Process control
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:liu:diva-77049Local ID: LiU-TEK-LIC-2012:12ISBN: 978-91-7519-919-1 (print)OAI: oai:DiVA.org:liu-77049DiVA: diva2:524729
Presentation
2012-05-25, Visionen, Hus B, Campus Valla, Linköpings universitet, Linköping, 10:15 (Swedish)
Opponent
Supervisors
Available from: 2012-05-08 Created: 2012-05-03 Last updated: 2012-05-08Bibliographically approved

Open Access in DiVA

Averaging level control in the presence of frequent inlet flow upsets(1968 kB)1699 downloads
File information
File name FULLTEXT01.pdfFile size 1968 kBChecksum SHA-512
d6816d1d8b34f684639696ecd4c6ad0d158014b459b11b1b185c7b7cb7d08eaea0edbc3eb34efb6be68121f070950568263eca0b38c480204c2da19e591d074b
Type fulltextMimetype application/pdf
omslag(99 kB)21 downloads
File information
File name COVER01.pdfFile size 99 kBChecksum SHA-512
d4045d649754c831058f6e356001a0e4f707dd50422b1609304584b1ac93963682dbca6f588ad8a53cd816e2edead95a9794739e27b111e73cbeaa86a1a9003e
Type coverMimetype application/pdf

Authority records BETA

Rosander, Peter

Search in DiVA

By author/editor
Rosander, Peter
By organisation
Automatic ControlThe Institute of Technology
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 1699 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 5031 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf