Heat Production, Nerve Function, and Morphology following Nerve Close Dissection with Surgical Instruments
Linköping University, Department of Clinical and Experimental Medicine. Linköping University, Faculty of Health Sciences.
Phys Technical Bundesanstalt.
Kalmar Hospital.
Sahlgrens University Hospital.
Show others and affiliations
2012 (English)In: World Journal of Surgery, ISSN 0364-2313, E-ISSN 1432-2323, Vol. 36, no 6, 1361-1367 p.Article in journal (Refereed) Published
Abstract [en]

The aim of the present study was to compare an ultrasonically activated instrument (US), monopolar electrosurgery, and bipolar electrosurgery (ES) with respect to heat production, nerve function, and nerve morphology following in vivo application. less thanbrgreater than less thanbrgreater thanThe biceps femoris muscle of anesthetized rats was cut in a standardized manner longitudinally 1 mm adjacent to the sciatic nerve using US shears, a monopolar ES knife, or a bipolar ES scissors. Activation time and temperature were recorded continuously within 1-4 mm of the activation site ipsilateral and contralateral to the nerve with two thermoelectric microsensors. Temperature rise and time delay of reaching the temperature maximum, as an expression of heat spread within tissue, maximum temperature, and thermal dose (equivalent time of exposure at 43A degrees C) were measured and calculated. A total of 49 functional experiments were conducted. The electromyographic (EMG) potential was recorded distally. Nerve dysfunction was defined as more than 10% loss of the evoked EMG amplitude. Forty-eight nerves were coded and submitted to blind histopathological examination, and morphological damage was graded on a 4-grade scale. less thanbrgreater than less thanbrgreater thanThe maximum temperature elevation and the thermal dose were significantly higher for the bipolar ES compared with the US instrument ( = 0.024, = 0.049), and with much less variation of results for the US instrument. The monopolar ES maximum temperature and thermal dose were lower, but a very large variation occurred, probably as a result of more random electrical spread to the ground electrode and muscle motion artifacts. Functional loss was least common in the US group-without being significant-compared to bipolar and monopolar ES. Moderate and severe morphological damage was significantly less common in the US group than in the monopolar ES group ( = 0.041). We found no statistically significant correlation between the highest temperatures and the degree of morphological damage or functional loss less thanbrgreater than less thanbrgreater thanThe temperature elevation depends strongly on the distance to the activated instrument. The bipolar ES scissors generates a higher maximum temperature and thermal dose with a greater variation in than the US. Functional loss and severe morphological damage were uncommon in all groups.

Place, publisher, year, edition, pages
Springer Verlag (Germany) , 2012. Vol. 36, no 6, 1361-1367 p.
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:liu:diva-78261DOI: 10.1007/s00268-012-1471-xISI: 000304096800022OAI: oai:DiVA.org:liu-78261DiVA: diva2:531857
Note
Funding Agencies|FORSS||Available from: 2012-06-08 Created: 2012-06-08 Last updated: 2017-12-07
In thesis
1. Energy based surgical instruments: With particular focus on collateral thermal injury
Open this publication in new window or tab >>Energy based surgical instruments: With particular focus on collateral thermal injury
2015 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Iatrogenic post-operative nerve dysfunction is a significant problem in many areas of surgery and can be caused by collateral thermal injury from activation of energy based surgical devices (EBD).

The aims of this thesis were to: create an animal model in order to compare mono- and bipolar electrosurgery (ES) and an ultrasonic dissection (UD) with regard to collateral thermal nerve injury, and with data of a national multicenter register to study the use of EBD and their potential effects on operation time and complication rates in thyroid surgery.urgical devices (EBD).

Material and Methods: The biceps femoris muscle of 104 anesthetized rats was cut in a standard manner adjacent to the sciatic nerve using clinical relevant settings of mono- and bipolar ES and UD. The sciatic nerve was stimulated supramaximally and the electromyographic (EMG) potential recorded before and after each experiment. Nerve dysfunction was defined as > 10% reduction of the evoked EMG potential. In Paper II and III temperature was measured before, during and after instrument activation. The sciatic nerves were coded and examined blinded with light (LM) and electron microscopy (EM). Advanced temperature measurements were conducted in Paper II and III. In Paper IV, the use of EBD was specifically registered in the Scandinavian Quality Register for Thyroid, Parathyroid and Adrenal Surgery (SQRTPA) during one year and 1297 patients were included. Operation time, recurrent laryngeal nerve (RLN) injury, post-operative hypoparathyroidism and the use of topical haemostatic agents were compared between bipolar ES, electric vessel sealing (EVS) and UD. Clamp and Tie technique (C-A-T) being without thermal risk constituted the control group.

Results: In Paper I the EMG potential was significantly more frequent reduced in the monopolar and bipolar ES group compared to the UD group and LM showed significantly less nerve damage in the UD group. In Paper II exact temperature measurements was possible with thermoelectric micros sensors and the thermal dose was significantly less and with less variation for the UD compared to the bipolar ES. Similar to the Paper I the EMG potential was significantly more frequent reduced in the ES group. Moderate and severe morphological damage was significantly less common in the UD group compared to monopolar ES. We found no statistical correlation between the highest temperatures/doses and the degree of morphological damage or functional loss. In Paper III the temperature increase was significantly less and with shorter duration in the UD group, compared to bipolar ES. LM and EM demonstrated loss of density in the myelin sheet only in a small number of nerves in all groups after instrument activation 1 mm from the nerve.

In Paper IV, operation time was significantly shorter in the UD group and significantly longer in the EVS and bipolar ES group, compared to C-A-T. Postoperative hypoparathyroidism with need for Calcium treatment at discharge and at 6 weeks was significantly higher with ES instruments compared to UD. The incidence of reported RLN injury was 2.5% at 6 weeks postoperatively without statistical differences between the groups. Topical haemostatic agents were more frequently used in the EBD groups compared to C-A-T.

Conclusion: The experimental Papers (I-III) demonstrated a lower risk of adverse collateral thermal nerve injury with activation of the mechanical UD technique compared to ES techniques. In the nationwide multicenter register Paper (IV), the use of UD shortened end EVS increased operation time compared to the low cost C-A-T. The UD instruments had a lower risk of hypoparathyroidism than electrosurgery.

Place, publisher, year, edition, pages
Linköping: Linköping University Electronic Press, 2015. 66 p.
Series
Linköping University Medical Dissertations, ISSN 0345-0082 ; 1491
National Category
Surgery
Identifiers
urn:nbn:se:liu:diva-122147 (URN)10.3384/diss.diva-122147 (DOI)978-91-7685-902-5 (ISBN)
Public defence
2015-11-20, Elsa Brännströmsalen, Campus US, Linköping, 10:00 (Swedish)
Opponent
Supervisors
Available from: 2015-10-20 Created: 2015-10-20 Last updated: 2015-10-20Bibliographically approved

Open Access in DiVA

fulltext(353 kB)547 downloads
File information
File name FULLTEXT01.pdfFile size 353 kBChecksum SHA-512
87a7d8eacc49d919e487dacda919618483a2ece1f9f0a06baf6133cff29b0b59a4bd3e9d0ae7b36fcc525df40be2b1691cb3766e0237d47e481c6c6c52a911d6
Type fulltextMimetype application/pdf

Other links

Publisher's full text

Authority records BETA

Gimm, Oliver

Search in DiVA

By author/editor
Gimm, Oliver
By organisation
Department of Clinical and Experimental MedicineFaculty of Health SciencesDepartment of Surgery in Östergötland
In the same journal
World Journal of Surgery
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 547 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 129 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf