Energieffektiv processventilation för aluminiumvarmvalsverk
Linköping University, Department of Management and Engineering, Energy Systems. Linköping University, The Institute of Technology.
Linköping University, Department of Management and Engineering, Energy Systems. Linköping University, The Institute of Technology.
2012 (Swedish)Independent thesis Basic level (degree of Bachelor), 10,5 credits / 16 HE creditsStudent thesisAlternative title
Energy-efficient proess ventilation for aluminum hot rolling mill (English)
Abstract [sv]

Syftet med detta examensarbete har varit att genomföra en nulägesanalys av Hall 7 på Sapa Heat Transfer AB i Finspång. Utifrån nulägesanalysen togs åtgärdsförslag fram som kan generera en effektivare uppvärmning, mindre yttre utsläpp och behagligare arbetsklimat. Problemet i Hall 7 är att processventilationen för varmvalsverk 2051 är ålderstigen och underdimensionerad, den saknar även värmeåtervinning och rening av processfrånluften. Detta leder till oplanerade driftstopp, höga underhållskostnader samt hög energianvändning.

För att finna åtgärdsförslag för dessa problem genomfördes en nulägesanalys av Hall 7 genom att mäta luftflöden och temperaturer, analysera utsläppsmätningar och energianvändning samt intervjua personal.

Utifrån dessa mätningar har fyra olika åtgärdsförslag tagits fram. De fyra åtgärdsförslagen är benämns: YIT, YIT (Enklare), Homehall och Ökad tilluft.

Det åtgärdsförslag som anses vara bäst lämpat för att generera en effektivare uppvärmning, ge mindre yttre utsläpp samt ett behagligare arbetsklimat i Hall 7 är åtgärdsförslag Homehall. Detta medför att Hall 7 kan bli nästintill självförsörjande med värme och fjärrvärmekostnaden kommer att sjunka markant. Mer om åtgärdsförslaget finns att läsa i 6.1.3 Värmeåtervinning från Homhall.

Under arbetets gång har även tre arbetsmiljöåtgärder tagits fram så som optimerad portstyrning för att minska värmeförluster och nedsmutsning, minskning av oljedimma genom ombyggnation av kåpa för processfrånluft och tätning av valsoljeläckage. Även åtgärder för undertryck för att uppnå tryckbalans och därmed bättre arbetsmiljö i Hall 7 har presenterats.

Förslag har även lämnats för fortsatt arbete gällande uppföljning av ventilationsstyrning, minskning av undertryck, kommunikation mellan personal och ledning, inställning hos personalen samt omkonstruktion av kåpa över varmvalsverk 2051.

Abstract [en]

The purpose of this bachelor thesis has been to conduct a situation analysis of Hall 7 at Sapa Heat Transfer AB in Finspång. Based on the current status analysis, proposals for action is to be developed that can generate a more efficient warm-up, less emission and a more pleasant work environment in Hall 7. The problem in Hall 7 is that the process ventilation for hot rolling mill 2051 is aged and undersized, it also does not have heat recovery or purification of the air which results in unplanned downtime, high maintenance costs and high use of energy.

To find proposals of action for these problems a current situation analysis was developed from measure of airflows and temperatures, analysis of external emissions, analysis of energy invoices and by interviewing employees.

From these measurements, four different proposals for action developed. The four proposals of action are named YIT, YIT (Simple), Homehal and Increased inlet air.

The proposed action that is considered best suited to generate a more efficient heating, giving small external emissions and a more pleasant work environment in Hall 7 is proposed action 6.1.3. This results in that Hall 7 becomes almost self-sufficient in heating and heating costs will drop significantly. More on the proposed measure can be found in 6.1.3 Värmeåtervinning från Homhall.

During the work, three health preventive actions developed, as optimized port control to reduce heat loss and pollution, reduction of oil vapor through reconstruction of housing for process ventilation and seal of oil leakage. Certain proposal of action has also been developed to achieve pressure balance in Hall 7 to achieve better work climate.

Place, publisher, year, edition, pages
2012. , 80 p.
Keyword [sv]
Energieffektiv, processventilation, aluminiumvarmvalsverk, Sapa Heat Tansfer
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:liu:diva-81914ISRN: LIU-IEI-TEK-G--12/00313--SEOAI: oai:DiVA.org:liu-81914DiVA: diva2:556487
External cooperation
Sapa Heat Transper AB
Subject / course
Energy Systems
Uppsok
Technology
Supervisors
Examiners
Available from: 2012-09-25 Created: 2012-09-25 Last updated: 2012-09-25Bibliographically approved

Open Access in DiVA

Energieffektiv processventialtion för aluminiumvarmvalsverk, Fredrik Tengvall & Tobias Olsson(3413 kB)461 downloads
File information
File name FULLTEXT01.pdfFile size 3413 kBChecksum SHA-512
7a98289cb5a6ae57dba2b753f42ab95e3afb87db409db11259ddf9f7cb48011c4c6c0078351856e97759aa7fd5fb45714f1ef78af425ce3c06ba613868286158
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Tengvall, FredrikOlsson, Tobias
By organisation
Energy SystemsThe Institute of Technology
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 461 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 403 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf