Spectroscopic Measurement of Cartilage Thickness in Arthroscopy: Ex Vivo Validation in Human Knee Condyles
Linköping University, Department of Biomedical Engineering, Physiological Measurements. Linköping University, The Institute of Technology.
Keele University, England Robert Jones and Agnes Hunt Orthopaed Hospital, England .
Linköping University, Department of Clinical and Experimental Medicine, Medical Microbiology. Linköping University, Faculty of Health Sciences.
BioOptico AB, Sweden .
Show others and affiliations
2012 (English)In: Arthroscopy: The Journal of Arthroscopy And Related, ISSN 0749-8063, E-ISSN 1526-3231, Vol. 28, no 10, 1513-1523 p.Article in journal (Refereed) Published
Abstract [en]

Purpose: To evaluate the accuracy of articular cartilage thickness measurement when implementing a new technology based on spectroscopic measurement into an arthroscopic camera. Methods: Cartilage thickness was studied by ex vivo arthroscopy at a number of sites (N = 113) in human knee joint osteoarthritic femoral condyles and tibial plateaus, removed from 7 patients undergoing total knee replacement. The arthroscopic image spectral data at each site were used to estimate cartilage thickness. Arthroscopically derived thickness values were compared with reference cartilage thickness as measured by 3 different methods: needle penetration, spiral computed tomography scanning, and geometric measurement after sample slicing. Results: The lowest mean error (0.28 to 0.30 mm) in the regression between arthroscopic and reference cartilage thickness was seen for reference cartilage thickness less than 1.5 mm. Corresponding values for cartilage thickness less than 2.0 and 2.5 mm were 0.32 to 0.40 mm and 0.37 to 0.47 mm, respectively. Cartilage thickness images-created by pixel-by-pixel regression model calculations applied to the arthroscopic images-were derived to demonstrate the clinical use of a camera implementation. Conclusions: On the basis of this investigation on osteoarthritic material, when one is implementing the spectroscopic method for estimating cartilage thickness into an arthroscopic camera, errors in the range of 0.28 to 0.30 mm are expected. This implementation does not, however, influence the fact that the spectral method performs less well in the cartilage thickness region from 1.5 to 2.5 mm and cannot assess cartilage thicker than 2.5 mm. Clinical Relevance: Imaging cartilage thickness directly in the arthroscopic camera video stream could serve as an interesting image tool for in vivo cartilage quality assessment, in connection with cartilage diagnosis, repair, and follow-up.

Place, publisher, year, edition, pages
WB Saunders , 2012. Vol. 28, no 10, 1513-1523 p.
National Category
Engineering and Technology
URN: urn:nbn:se:liu:diva-85201DOI: 10.1016/j.arthro.2012.03.009ISI: 000309602500026OAI: diva2:566642

Funding Agencies|BioOptico AB||ConMed||

Available from: 2012-11-09 Created: 2012-11-09 Last updated: 2012-11-09

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Johansson, AndersSundqvist, TommyÖberg, Åke
By organisation
Physiological MeasurementsThe Institute of TechnologyMedical MicrobiologyFaculty of Health Sciences
In the same journal
Arthroscopy: The Journal of Arthroscopy And Related
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 186 hits
ReferencesLink to record
Permanent link

Direct link