Evaluation of Automatic Measurement of the Intracranial Volume Based on Quantitative MR Imaging
Umeå University, Sweden .
Umeå University, Sweden .
Umeå University, Sweden .
SyntheticMR ABE, Linköping, Sweden .
Show others and affiliations
2012 (English)In: American Journal of Neuroradiology, ISSN 0195-6108, E-ISSN 1936-959X, Vol. 33, no 10, 1951-1956 p.Article in journal (Refereed) Published
Abstract [en]

BACKGROUND AND PURPOSE: Brain size is commonly described in relation to ICV, whereby accurate assessment of this quantity is fundamental. Recently, an optimized MR sequence (QRAPMASTER) was developed for simultaneous quantification of T1, T2, and proton density. ICV can be measured automatically within minutes from QRAPMASTER outputs and a dedicated software, SyMRI. Automatic estimations of ICV were evaluated against the manual segmentation. MATERIALS AND METHODS: In 19 healthy subjects, manual segmentation of ICV was performed by 2 neuroradiologists (Obs1, Obs2) by using QBrain software and conventional T2-weighted images. The automatic segmentation from the QRAPMASTER output was performed by using SyMRI. Manual corrections of the automatic segmentation were performed (corrected-automatic) by Obs1 and Obs2, who were blinded from each other. Finally, the repeatability of the automatic method was evaluated in 6 additional healthy subjects, each having 6 repeated QRAPMASTER scans. The time required to measure ICV was recorded. RESULTS: No significant difference was found between reference and automatic (and corrected-automatic) ICV (P greater than .25). The mean difference between the reference and automatic measurement was -4.84 +/- 19.57 mL (or 0.31 +/- 1.35%). Mean differences between the reference and the corrected-automatic measurements were -0.47 +/- 17.95 mL (-0.01 +/- 1.24%) and -1.26 +/- 17.68 mL (-0.06 +/- 1.22%) for Obs1 and Obs2, respectively. The repeatability errors of the automatic and the corrected-automatic method were less than1%. The automatic method required 1 minute 11 seconds (SD = 12 seconds) of processing. Adding manual corrections required another 1 minute 32 seconds (SD = 38 seconds). CONCLUSIONS: Automatic and corrected-automatic quantification of ICV showed good agreement with the reference method. SyMRI software provided a fast and reproducible measure of ICV.

Place, publisher, year, edition, pages
American Society of Neuroradiology , 2012. Vol. 33, no 10, 1951-1956 p.
National Category
Medical and Health Sciences
URN: urn:nbn:se:liu:diva-87219DOI: 10.3174/ajnr.A3067ISI: 000311711400020OAI: diva2:587404
Available from: 2013-01-14 Created: 2013-01-14 Last updated: 2013-01-28

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Warntjes, Marcel Jan Bertus
By organisation
Center for Medical Image Science and Visualization, CMIVClinical PhysiologyFaculty of Health SciencesDepartment of Clinical Physiology UHL
In the same journal
American Journal of Neuroradiology
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 76 hits
ReferencesLink to record
Permanent link

Direct link