liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Fault Tolerant Supervision of an Industrial Gas Turbine
Linköping University, The Institute of Technology. Linköping University, Department of Electrical Engineering, Vehicular Systems.
Linköping University, The Institute of Technology. Linköping University, Department of Electrical Engineering, Vehicular Systems.
Linköping University, Department of Electrical Engineering, Vehicular Systems. Linköping University, The Institute of Technology.
Linköping University, The Institute of Technology. Linköping University, Department of Electrical Engineering, Vehicular Systems.
2013 (English)In: Proceedings of ASME Turbo Expo, 2013Conference paper, Published paper (Refereed)
Abstract [en]

Supervision of the performance of an industrial gas turbine is important since it gives valuable information of the process health and makes efficient determination of compressor wash intervals possible. Slowly varying sensor faults can easily be misinterpreted as performance degradations and result in an unnecessary compressor wash. Here, a diagnostic algorithm is carefully combined with non-linear state observers to achieve fault tolerant performance estimation. The proposed approach is evaluated in an experimental case study with six months of measurement data from a gas turbine site. The investigation shows that faults in all gas path instrumentation sensors are detectable and isolable. A key result of the case study is the ability to detect and isolate a slowly varying sensor fault in the discharge temperature sensor after the compressor. The fault is detected and isolated before the wash condition of the compressor is triggered, resulting in fault tolerant estimation of compressor health parameters.charge temperature sensor after the compressor. The fault is detected and isolated before the wash condition of the compressor is triggered, resulting in fault tolerant estimation of compressor health parameters.

Place, publisher, year, edition, pages
2013.
National Category
Control Engineering
Identifiers
URN: urn:nbn:se:liu:diva-89299DOI: 10.1115/GT2013-95727ISBN: 978-0-7918-5518-8 (print)OAI: oai:DiVA.org:liu-89299DiVA: diva2:607645
Conference
ASME 2013 Turbo Expo: Turbine Technical Conference and Exposition (GT2013), June 3-7, 2013, San Antonio, Texas, USA.
Available from: 2013-02-25 Created: 2013-02-25 Last updated: 2014-11-27

Open Access in DiVA

No full text

Other links

Publisher's full text

Authority records BETA

Larsson, EmilÅslund, JanFrisk, ErikEriksson, Lars

Search in DiVA

By author/editor
Larsson, EmilÅslund, JanFrisk, ErikEriksson, Lars
By organisation
The Institute of TechnologyVehicular Systems
Control Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric score

doi
isbn
urn-nbn
Total: 306 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf