liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Whole spine CT for evaluation of scoliosis in children: feasibility of sub-milliSievert scanning protocol
Massachusetts General Hospital, Boston, MA, USA .
Linköping University, Center for Medical Image Science and Visualization (CMIV). Linköping University, Department of Medical and Health Sciences, Radiology. Linköping University, Faculty of Health Sciences. Östergötlands Läns Landsting, Center for Diagnostics, Department of Radiology in Linköping.
Massachusetts General Hospital, Boston, MA, USA .
Linköping University, Center for Medical Image Science and Visualization (CMIV). Linköping University, Department of Medical and Health Sciences, Radiation Physics. Linköping University, Faculty of Health Sciences. Östergötlands Läns Landsting, Center for Surgery, Orthopaedics and Cancer Treatment, Department of Radiation Physics.ORCID iD: 0000-0003-3352-8330
Show others and affiliations
2013 (English)In: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 54, no 2, 226-230 p.Article in journal (Refereed) Published
Abstract [en]

Background Optimization of CT radiation dose is important for children due to their higher risk of radiation-induced adverse effects. Anatomical structures with high inherent contrast, such as bones can be imaged at very low radiation doses by optimizing scan parameters.                    

Purpose To assess feasibility of sub-milliSievert whole spine CT scanning protocol for evaluation of scoliosis in children.                    

Material and Methods With approval of the ethical board, we performed whole spine CT for evaluation of scoliosis in 22 children (age range, 3–18 years; mean age, 13 years; 13 girls, 9 boys) on a 128-slice dual source multidetector-row CT scanner. Lowest possible quality reference mAs value (image quality factor for xy-z automatic exposure control or xyz-AEC, CARE Dose 4D) was selected on a per patient basis. Remaining parameters were held constant at 3.0:1 pitch, 128 × 0.6 mm detector collimation, 115.2 mm table feed per gantry rotation, 100 kVp, and 1 and 3 mm reconstructed sections. Average mAs, projected estimated dose savings with AEC, computed tomography dose index volume (CTDI vol), and dose length product (DLP) were recorded. Artifacts were graded on a four-point scale (1, no artifacts; 4, severe artifacts). Ability to identify vertebral and pedicular contours, and measure pedicular width and degree of vertebral rotation was graded on a three-point scale (1, unacceptable; 3, excellent).       

Results All CT examinations were deemed as reliable for identifying vertebral and pedicular contours as well as for measuring pedicular width (5.9 ± 1.6 mm) and degree of vertebral rotation (28.7 ± 23.4°). Mean objective image noise and signal to noise ratio (SNR) were 57.5 ± 21.5 and 4.7 ± 2.3, respectively. With a mean quality reference mAs of 13, the scanner employed an average actual effective mAs of 10 ± 3.8 (range, 6–18 mAs) with an estimated radiation dose saving of 43.5 ± 16.3% with xyz-AEC compared with fixed mAs. The mean CTDI, DLP, and estimated effective doses were 0.4 ± 0.1 mGy (0.2–0.7 mGy), 21 ± 10 mGy.cm (8–41 mGy.cm), and 0.3 ± 0.1 mSv (0.12–0.64 mSv), respectively.                    

Conclusion Radiation dose for whole spine CT for evaluation of scoliosis in children can be minimized to less than one-third of a milliSievert while maintaining diagnostic image quality.

Place, publisher, year, edition, pages
Sage Publications, 2013. Vol. 54, no 2, 226-230 p.
Keyword [en]
CT, scoliosis, radiation dose, automatic exposure control
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:liu:diva-91219DOI: 10.1258/ar.2012.110625ISI: 000322321400015PubMedID: 23138023OAI: oai:DiVA.org:liu-91219DiVA: diva2:617076
Available from: 2013-04-22 Created: 2013-04-17 Last updated: 2017-12-06

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Authority records BETA

Quick, PetterSandborg, MichaelPersson, Anders

Search in DiVA

By author/editor
Quick, PetterSandborg, MichaelPersson, Anders
By organisation
Center for Medical Image Science and Visualization (CMIV)RadiologyFaculty of Health SciencesDepartment of Radiology in LinköpingRadiation PhysicsDepartment of Radiation Physics
In the same journal
Acta Radiologica
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 110 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf