Optimization of Dual Energy data acquisition using CdTe-detectors with electronic spectrum splitting
Linköping University, The Institute of Technology. Linköping University, Department of Biomedical Engineering, Biomedical Instrumentation.
2013 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

Dual energy imaging has made it possible to enhance contrast in medical images using images containing different energy information, by combining low and high energy images. Dual energy data can either be acquired using double exposures or splitting the energy spectrum into two images using one exposure.

This thesis presents investigations of dual energy imaging using a detector solution developed by XCounter which provides dual energy images in a single exposure with a threshold separating low and high energy images. Phantom experiments with phantoms of aluminum and plexiglas were performed using weighted logarithmic subtraction and basis material decomposition to produce dual energy images. Methods were validated and images were evaluated in terms of signal difference in noise ratio to find the threshold and tube voltage combination for optimum energy spectrum separation. The methods were also tested on biological materials using bone, soft tissue and iodine solution as contrast enhancer, to investigate K-edge imaging. 

Optimal separation of plexiglas and aluminum were found at 70 kVp and the threshold parameter set within a range of 8 to 9, which corresponds to approximately 30 to 34 keV. For K-edge imaging, the optimum separation were found close to K-edge energy of iodine. The results found in the phantom study correlated with results from the biological material study.

Place, publisher, year, edition, pages
2013. , p. 81
Keywords [en]
Dual Energy, CdTe, X-ray, photon-counting detectors
National Category
Medical Engineering
Identifiers
URN: urn:nbn:se:liu:diva-94742ISRN: LiTH-IMT/BIT30-A-EX--13/511--SEOAI: oai:DiVA.org:liu-94742DiVA, id: diva2:634764
External cooperation
XCounter AB
Subject / course
Biomedical Instrumentation
Examiners
Available from: 2013-07-04 Created: 2013-07-01 Last updated: 2013-08-20Bibliographically approved

Open Access in DiVA

Optimization of Dual Energy data acquisition(6613 kB)790 downloads
File information
File name FULLTEXT02.pdfFile size 6613 kBChecksum SHA-512
1c0bead2a4abd8d05458d3747770897d4f88e288330151e1941e38e9c22aa1775d69aaca10e32ddbf5a1328e46dec8bde2fbf0c7b337c4f41cbe7834b3b137fa
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Eriksson, Charlotte
By organisation
The Institute of TechnologyBiomedical Instrumentation
Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 790 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 382 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf