liu.seSearch for publications in DiVA
Change search
ReferencesLink to record
Permanent link

Direct link
Bisphosphonate-coated external fixation pins appear similar to hydroxyapatite-coated pins in the tibial metaphysis and to uncoated pins in the shaft: a randomized trial
Department of Orthopedics, Hässleholm Hospital, Hässleholm, and Department of Orthopedics, Clinical Sciences, Lund University , Lund.
Linköping University, Department of Clinical and Experimental Medicine, Division of Inflammation Medicine. Linköping University, Faculty of Health Sciences. Östergötlands Läns Landsting, Center for Surgery, Orthopaedics and Cancer Treatment, Department of Orthopaedics in Linköping.
2013 (English)In: Acta Orthopaedica, ISSN 1745-3674, E-ISSN 1745-3682, Vol. 84, no 3, 314-318 p.Article in journal (Refereed) Published
Abstract [en]

Background and purpose External fixation pins tend to loosen with time, especially from cancellous bone. A coating that releases a bisphosphonate has been shown to improve the fixation of dental implants in humans. We now tested a bisphosphonate coating on steel pins for external fixation. The primary hypothesis was that coated pins would be better fixed in the diaphysis.

Methods 20 patients with medial knee osteoarthritis underwent proximal tibial correction osteotomy with hemicallotasis. They received a pair of pins (Orthofix) in the tibial shaft, one bisphosphonate-coated and one uncoated. Another pair of pins was inserted in the metaphysis, near the joint. This pair was a bisphosphonate-coated pin and an HA-coated pin. All pins were inserted according to a random list. The pins were removed after the osteotomy had healed (8–15 weeks), and extraction torque served as the predetermined main outcome variable.

Results No pins showed clinical signs of loosening. Removal torque for the shaft pins was 6.6 Nm (SD 2.2) for the bisphosphonate and 6.0 Nm (SD 2.5) for the uncoated (difference = 0.5, 95% CI: –0.03 to 1.3). Removal torque for the metaphyseal pins was 4.4 Nm (SD 1.3) for the bisphosphonate-coated and 4.2 Nm (SD 1.6) for the HA-coated (difference = 0.2, 95% CI: –0.5 to 1.0).

Interpretation We could not show any improved cortical fixation, but the metaphyseal findings are striking. In a previous study on 19 patients with a similar layout, HA-coated and uncoated pins were compared. In the metaphysis, all 19 uncoated pins loosened before removal. It was concluded that uncoated pins could not be used in the metaphyseal region. The present results suggest that a bisphosphonate coating enables metaphyseal fixation similar to that of hydroxyapatite coatings, with no difference from uncoated pins in cortical bone.

Place, publisher, year, edition, pages
Informa Healthcare , 2013. Vol. 84, no 3, 314-318 p.
National Category
Medical and Health Sciences
URN: urn:nbn:se:liu:diva-96486DOI: 10.3109/17453674.2013.797315ISI: 000319749900015OAI: diva2:642884
Available from: 2013-08-23 Created: 2013-08-20 Last updated: 2013-10-02

Open Access in DiVA

fulltext(200 kB)158 downloads
File information
File name FULLTEXT01.pdfFile size 200 kBChecksum SHA-512
Type fulltextMimetype application/pdf

Other links

Publisher's full text

Search in DiVA

By author/editor
Aspenberg, Per
By organisation
Division of Inflammation MedicineFaculty of Health SciencesDepartment of Orthopaedics in Linköping
In the same journal
Acta Orthopaedica
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 158 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 57 hits
ReferencesLink to record
Permanent link

Direct link