Uteluftventilerad krypgrund-En sedan länge välkänd riskkonstruktion som fortsätter byggas
Linköping University, Department of Science and Technology. Linköping University, The Institute of Technology.
2005 (Swedish)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesisAlternative title
Outdoor air-ventilated crawlspaces-A well-known risk-construction that is still built (English)
Abstract [sv]

Uteluftventilerade krypgrunder drabbas ofta av fuktrelaterade problem och kunskapen om varför finns sedan länge. Ändå byggs konstruktionen i stor skala i det utförande som kommer att ge brukarna problem i framtiden med hälsa och/eller kostnader för att åtgärda problemen.

Denna rapport beskriver hur en uteluftventilerad krypgrund fungerar fukttekniskt sätt, visar paralleller till den äldre torpargrunden samt reder ut varför grunderna fortsätter byggas trots de brister som påvisats.

För att få förståelse vilka svåra problem som kan uppstå i en uteluftventilerad krypgrund finns ett eget kapitel med olika typer av mögel och äkta hussvamp där kännetecken och egenskaper redovisas. Det finns också ett kapitel med förslag på olika åtgärder som kan vara lämpliga då problem upptäckts i en krypgrund.

Småhusskadenämden är en statlig myndighet som lämnar bidrag till kostnaderna för att åtgärda fukt- och mögelskador i en- och tvåfamiljshus och de har märkt en tydlig ökning av anmälningar med krypgrunder.

Fuktcentrum i Lund har lång erfarenhet av och har forskat kring problematiken med krypgrunder och klassar konstruktionen som en högriskkonstruktion som inte bör utföras i sin grundform med oisolerade grundmurar och plastfolie på grundbotten.

Boverket har insett vidden av problemen och kommer att ändra sina byggregler till nästa revidering så att direktiven vid nybyggande blir tydligare.

Telefonintervjuer med tio stycken olika, större husleverantörer har gjorts för att undersöka deras  nställning till uteluftventilerade krypgrunder. Resultatet visar att de flesta ser konstruktionen som en risk och inte längre använder sig av den men det finns några av företagen som inriktar sig på större produktion med färdiga husmoduler som bara kan monteras på krypgrunder.

Abstract [en]

Outdoor air-ventilated crawlspaces often get affected by moisture-related problems and the knowledge of why has been known since long. Yet the construction is built on a larger scale in the performance that will give its users future problems with health and/or costs to attend the problems. This report describes how an outdoor air-ventilated crawlspace functions technically with moist, shows parallels to the older model and investigates why the constructions still are built despite of the shortcomings that have been proven.

To get an understanding for the complex problems that can occur in an outdoor air-ventilated crawlspace there is an own chapter with different kinds of mould and fungus where signs and characters are defined. There is also a chapter with suggestions to different solutions that can be applied when problems are revealed in a crawlspace.

Småhusskadenämden is a government authority that gives contributions to attend moist- and mould damages in one- and two-family houses and they have noticed a clear increase of reports with crawlspaces.

Fuktcentrum in Lund has a long experience of and have researched around crawlspaces and classifies the construction as a high-risk construction that shouldn’t be performed in it’s original form with un-isolated walls and plastic-foil on the ground.

Boverket have realized the width of the problems and will change their building-regulations to the next revision so that the directives are clearer.

Telephone-interviews with ten different, bigger house-suppliers have been done to investigate their attitude towards outdoor air-ventilated crawlspaces. The results show that the majority of them see the construction as a risk and no longer use it but there are a few of the companies that aim at bigger production with house-modules that only can be assembled on to a outdoor air-ventilated crawlspace.

Place, publisher, year, edition, pages
2005. , 40 p.
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:liu:diva-97918ISRN: LITH-ITN-EX--05/022--SEOAI: oai:DiVA.org:liu-97918DiVA: diva2:653611
Subject / course
Engineering Materials
Supervisors
Examiners
Available from: 2013-10-04 Created: 2013-09-23 Last updated: 2013-10-04Bibliographically approved

Open Access in DiVA

fulltext(1304 kB)314 downloads
File information
File name FULLTEXT01.pdfFile size 1304 kBChecksum SHA-512
5563d27fafba3e3ab9778d16dc67c931eb9d6ddf0fb71e8696d8ddcbcf39664329ccc3e15bf255744600fa50109cff4ee9df6c0f697832480a94d46af6c23923
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Öberg, Johan
By organisation
Department of Science and TechnologyThe Institute of Technology
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 314 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 379 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf