liu.seSearch for publications in DiVA
Change search
ReferencesLink to record
Permanent link

Direct link
Stimulation of implant fixation by parathyroid hormone (1-34)-A histomorphometric comparison of PMMA cement and stainless steel.
Orthopaedic Department, University Hospital Eppendorf, Hamburg, Germany.
Orthopaedic Department, University Hospital Eppendorf, Hamburg, Germany.
Orthopaedic Department, University Hospital Eppendorf, Hamburg, Germany.
Linköping University, Department of Neuroscience and Locomotion, Orthopaedics and Sports Medicine. Linköping University, Faculty of Health Sciences.
2005 (English)In: Journal of Orthopaedic Research, ISSN 0736-0266, E-ISSN 1554-527X, Vol. 23, no 6, 1266-70 p.Article in journal (Refereed) Published
Abstract [en]

Whereas continuous exposure to PTH results in bone resorption, PTH administration at intermittent doses results in bone formation by increasing osteoblast number and activity. PTH leads to faster fracture repair and better fixation of orthopaedic implants in animal models. The present study evaluates if PTH is able to increase the contact surface between bone and implant and whether the effect of PTH is dependent on implant material characteristics. The implants were made as rods, either of stainless steel or Palacos R bone-cement. The steel rods had a surface roughness of R(a) 0.1 microm and the cement rods R(a) 2.2 microm. In 40 adult male rats, one cement rod was inserted in the left tibia and one steel rod in the right tibia. After implantation, the rats were divided into groups by random. One group was injected three times a week with human PTH (1-34) at a dose of 60 microg/kg BW/injection. The second group was injected with the vehicle only. Both groups were then divided into groups for 2 and 4 weeks time till tibial harvest. The tibial segments around the hole of the rods were then prepared by standard histological techniques. The linear tissue surfaces, that had been in contact with the surface of the rod, were analyzed in a blind fashion. PTH increased the bone contact fraction compared with the vehicle in the steel group from 7.4 (SD 7.6) to 21.1 (SD 10.7) % after 2 weeks and from 9.8 (SD 8.1) to 47.1 (SD 13.3) % after 4 weeks. In the cement group PTH increased the contact index again compared with the vehicle from 7.8 (SD 10.2) to 53.6 (SD 26.3) % already after 2 weeks and from 14.3 (SD 15) to 65.6 (SD 15.7) % after 4 weeks. The bone trabeculae adjacent to the implant had become fewer and thicker after the treatment with PTH (1-34), with an increase of the bone mass in the area next to the bone-implant-interface. The earlier onset of PTH effects in the rougher cement group suggests that intermittent PTH treatment might lead to an increased micro-interlock between implant and bone, and might therefore be considered as a possible drug to enhance incorporation of orthopedic implants.

Place, publisher, year, edition, pages
Hoboken, NJ, United States: John Wiley & Sons, 2005. Vol. 23, no 6, 1266-70 p.
Keyword [en]
Arthroplasty, Replacement, Hip, Cyclooxygenase 2 Inhibitors/adverse effects, Cyclooxygenase Inhibitors/*adverse effects, Humans, Osteogenesis/drug effects, Pain, Postoperative/drug therapy, *Prosthesis Failure, Risk Factors
National Category
Medical and Health Sciences
URN: urn:nbn:se:liu:diva-99482DOI: 10.1016/j.orthres.2005.04.006.1100230605ISI: 000233148800004PubMedID: 15964166OAI: diva2:657317
Available from: 2013-10-18 Created: 2013-10-18 Last updated: 2014-06-18Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Aspenberg, Per
By organisation
Orthopaedics and Sports MedicineFaculty of Health Sciences
In the same journal
Journal of Orthopaedic Research
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 46 hits
ReferencesLink to record
Permanent link

Direct link