An ultrasensitive molecularly-imprinted human cardiac troponin sensor
Linköping University, Department of Physics, Chemistry and Biology, Biosensors and Bioelectronics. Linköping University, The Institute of Technology. Ferdowsi University of Mashhad, Iran.
Linköping University, Department of Physics, Chemistry and Biology, Applied Physics. Linköping University, The Institute of Technology.
Ferdowsi University of Mashhad, Iran .
Ferdowsi University of Mashhad, Iran .
Show others and affiliations
2013 (English)In: Biosensors & bioelectronics, ISSN 0956-5663, E-ISSN 1873-4235, Vol. 50, 492-498 p.Article in journal (Refereed) Published
Abstract [en]

Cardiac troponin T (TnT) is a highly sensitive cardiac biomarker for myocardial infarction. In this study, the fabrication and characterisation of a novel sensor for human TnT based on a molecularly-imprinted electrosynthesised polymer is reported. A TnT sensitive layer was prepared by electropolymerisation of o-phenylenediamine (o-PD) on a gold electrode in the presence of TnT as a template. To develop the molecularly imprinted polymer (MIP), the template molecules were removed from the modified electrode surface by washing with alkaline ethanol. Electrochemical methods were used to monitor the processes of electropolymerisation, template removal and binding. The imprinted layer was characterised by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and atomic force microscopy (AFM). The incubation of the MIP-modified electrode with respect to TnT concentration resulted in a suppression of the ferro/ferricyanide redox process. Experimental conditions were optimised and a linear relationship was observed between the peak current of [Fe(CN)(6)](3-)/[Fe (CN)(6)](4-) and the concentration of TnT in buffer over the range 0.009-0.8 ng/mL, with a detection limit of 9 pg/mL. The TnT MIP sensor was shown to have a high affinity to TnT in comparison with nonimprinted polymer (NIP) electrodes in both buffer and blood serum.

Place, publisher, year, edition, pages
Elsevier, 2013. Vol. 50, 492-498 p.
Keyword [en]
Cardiac biomarker, troponin T, Molecularly imprinted polymer electrode, MIP sensor
National Category
Medical Engineering
URN: urn:nbn:se:liu:diva-100299DOI: 10.1016/j.bios.2013.07.013ISI: 000325188200076OAI: diva2:661521
Swedish Research Council, 2011-5225

Funding Agencies|European Commission|PIIF-GA-2009-254955|LIST, Linkoping University||Ministry of Science, Research and Technology of Iran||

Available from: 2013-11-04 Created: 2013-11-04 Last updated: 2014-01-22Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Vagin, MikhailTurner, AnthonyTiwari, Ashutosh
By organisation
Biosensors and BioelectronicsThe Institute of TechnologyApplied Physics
In the same journal
Biosensors & bioelectronics
Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 271 hits
ReferencesLink to record
Permanent link

Direct link