Inverse Monte Carlo in a multilayered tissue model: merging diffuse reflectance spectroscopy and laser Doppler flowmetry
Linköping University, Department of Biomedical Engineering, Biomedical Instrumentation. Linköping University, The Institute of Technology. Perimed AB, Järfälla, Sweden. (Tomas Strömberg)ORCID iD: 0000-0002-3454-6576
Linköping University, Department of Mathematics, Optimization . Linköping University, The Institute of Technology.ORCID iD: 0000-0003-1836-4200
Linköping University, Department of Biomedical Engineering, Biomedical Instrumentation. Linköping University, The Institute of Technology. (Tomas Strömberg)ORCID iD: 0000-0001-6385-6760
Linköping University, Department of Biomedical Engineering, Biomedical Instrumentation. Linköping University, The Institute of Technology. (Tomas Strömberg)ORCID iD: 0000-0002-7299-891X
2013 (English)In: Journal of Biomedical Optics, ISSN 1083-3668, E-ISSN 1560-2281, Vol. 18, no 12, p. 127004-1-127004-14Article in journal (Refereed) Published
Abstract [en]

The tissue fraction of red blood cells (RBCs) and their oxygenation and speed-resolved perfusion areestimated in absolute units by combining diffuse reflectance spectroscopy (DRS) and laser Doppler flowmetry(LDF). The DRS spectra (450 to 850 nm) are assessed at two source–detector separations (0.4 and 1.2 mm), allowingfor a relative calibration routine, whereas LDF spectra are assessed at 1.2mmin the same fiber-optic probe. Data areanalyzed using nonlinear optimization in an inverse Monte Carlo technique by applying an adaptive multilayeredtissue model based on geometrical, scattering, and absorbing properties, as well as RBC flow-speed information.Simulations of 250 tissue-like models including up to 2000 individual blood vessels were used to evaluatethe method. The absolute root mean square (RMS) deviation between estimated and true oxygenation was 4.1percentage units, whereas the relative RMS deviations for the RBC tissue fraction and perfusion were 19% and23%, respectively. Examples of in vivo measurements on forearm and foot during common provocations arepresented. The method offers several advantages such as simultaneous quantification of RBC tissue fractionand oxygenation and perfusion from the same, predictable, sampling volume. The perfusion estimate is speedresolved, absolute (% RBC × mm∕s), and more accurate due to the combination with DRS.

Place, publisher, year, edition, pages
Bellingham, WA, United States: SPIE - International Society for Optical Engineering, 2013. Vol. 18, no 12, p. 127004-1-127004-14
Keywords [en]
diffuse reflectance spectroscopy; laser Doppler flowmetry; modeling; Monte Carlo simulations; inverse engineering; nonlinear optimization; blood oxygen saturation; speed-resolved perfusion
National Category
Medical Equipment Engineering
Identifiers
URN: urn:nbn:se:liu:diva-102707DOI: 10.1117/1.JBO.18.12.127004ISI: 000331706500045OAI: oai:DiVA.org:liu-102707DiVA, id: diva2:681131
Funder
VINNOVA, 2011-03074Available from: 2013-12-19 Created: 2013-12-19 Last updated: 2021-12-28Bibliographically approved

Open Access in DiVA

fulltext(1368 kB)688 downloads
File information
File name FULLTEXT01.pdfFile size 1368 kBChecksum SHA-512
01a10300988d73c0feabf2fa5af33323051913cf0367e037dd554a44ef63acb105aa1713656f27b9536770d274616f20f2ab91fd22958fbab45938c214b54c7c
Type fulltextMimetype application/pdf

Other links

Publisher's full text

Authority records

Fredriksson, IngemarBurdakov, OlegLarsson, MarcusStrömberg, Tomas

Search in DiVA

By author/editor
Fredriksson, IngemarBurdakov, OlegLarsson, MarcusStrömberg, Tomas
By organisation
Biomedical InstrumentationThe Institute of TechnologyOptimization
In the same journal
Journal of Biomedical Optics
Medical Equipment Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 688 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 951 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf