Comparison of intraoperative fluorescence and MRI image guided neuronavigation in malignant brain tumours, a prospective controlled study
Department Radiol, Scotland .
Linköping University, Faculty of Health Sciences.
Scottish PDT Centre, UK.
Scottish PDT Centre, UK.
Show others and affiliations
2013 (English)In: Photodiagnosis and Photodynamic Therapy, ISSN 1572-1000, Vol. 10, no 4, 356-361 p.Article in journal (Refereed) Published
Abstract [en]

Introduction: MBT carry poor prognosis and more than 80% of MBT recur locally within 2 cm of the resection margin because of inadequate surgical removal. A number of techniques have been implemented in recent years to improve surgical removal of MBT with variable success. We examined two methods commonly used to resect MBT to establish which one offered the best chances of gross total removal; MRI guided technology and ALA-induced fluorescence. Patients and methods: Twenty consecutive patients diagnosed with MBT were included in this study. They were given 20 mg ALA per kg body weight 3 h before anaesthesia orally mixed in water. Surgery was planned using preoperative enhanced MPR age images. Surgery was executed using the Stealth Station image guidance system and ALA-induced fluorescence microsurgical techniques. During surgery the intensity of fluorescence was graded into red, pink or blue. The intensity of fluorescence was also measured using pulsed 405 nm laser and a compact spectrometer using a touch probe directly placed on the tissue. The extent of tumour invasion was assessed intraoperatively using standard white light, blue light and spectroscopic measurements. Postoperative enhanced MRI was used to assess the extent of resection and the volume of residual tumour was measured. Results: There were six newly diagnosed GBM, eight recurrent GBM, one oligodendroglioma (ODG) and five metastases (MET). On enhanced MRI, the mean diameter of new GBM, recurrent GBM, ODG and MET was 2.3 cm, 2.3 cm, 1.5 cm, and 2.3 cm respectively. Under the blue light, the mean diameter of new GBM, recurrent GBM, ODG and MET was 2.9 cm, 3 cm, 1.5 cm and 2.3 cm respectively. The results of quantitative measurements of fluorescence ratios revealed that red fluorescence corresponded to 5.9-11.6 (solid tumour on histology), and pink fluorescence measured 0.8-1.9 (infiltrating edge of tumour on histology). When we compared the maximum tumour diameter of GBM we found on average it was 10 mm wider on spectroscopy compared to standard white light microscopy and 6 mm wider than what the enhanced MRI demonstrated. Conclusions: Fluorescence technology revealed that GBMs are wider than the enhanced MRI had demonstrated, while MET enhanced MRI was similar in size to fluorescence. Furthermore, solid tumour can be identified intraoperatively and can be measured using fluorescence and spectroscopy techniques and it can be removed safely. Infiltrating tumour can also be identified intraoperatively using this technology and can be removed in non-eloquent areas to maximise surgical resection.

Place, publisher, year, edition, pages
Elsevier , 2013. Vol. 10, no 4, 356-361 p.
Keyword [en]
Fluorescence; Glioma; High grade glioma; Metastases; Surgery
National Category
Engineering and Technology
URN: urn:nbn:se:liu:diva-103299DOI: 10.1016/j.pdpdt.2013.03.006ISI: 000328666900004OAI: diva2:688483
Available from: 2014-01-17 Created: 2014-01-16 Last updated: 2014-01-17

Open Access in DiVA

No full text

Other links

Publisher's full text
By organisation
Faculty of Health Sciences
In the same journal
Photodiagnosis and Photodynamic Therapy
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 12 hits
ReferencesLink to record
Permanent link

Direct link