In-situ calibration of clinical built-in KAP meters with traceability to a primary standard using a reference KAP meter
Linköping University, Department of Medical and Health Sciences, Division of Radiological Sciences. Linköping University, Faculty of Health Sciences.ORCID iD: 0000-0003-1257-2383
Linköping University, Department of Medical and Health Sciences, Division of Radiological Sciences. Linköping University, Faculty of Health Sciences. Östergötlands Läns Landsting, Center for Surgery, Orthopaedics and Cancer Treatment, Department of Radiation Physics.
Linköping University, Center for Medical Image Science and Visualization (CMIV). Linköping University, Department of Medical and Health Sciences, Division of Radiological Sciences. Linköping University, Faculty of Health Sciences. Östergötlands Läns Landsting, Center for Surgery, Orthopaedics and Cancer Treatment, Department of Radiation Physics.ORCID iD: 0000-0003-3352-8330
Swedish Radiat Protect Author, Sweden.
Show others and affiliations
2014 (English)In: Physics in Medicine and Biology, ISSN 0031-9155, E-ISSN 1361-6560, Vol. 59, no 23, 7195-7210 p.Article in journal (Refereed) Published
Abstract [en]

The air kerma-area product (KAP) is used for settings of diagnostic reference levels. The International Atomic Energy Agency (IAEA) recommends that doses in diagnostic radiology (including the KAP values) be estimated with an accuracy of at least +/- 7% (k = 2). Industry standards defined by the International Electrotechnical Commission (IEC) specify that the uncertainty of KAP meter measurements should be less than +/- 25% (k = 2). Medical physicists willing to comply with the IAEAs recommendation need to apply correction factors to KAP values reported by x-ray units. The aim of this work is to present and evaluate a calibration method for built-in KAP meters on clinical x-ray units. The method is based on (i) a tandem calibration method, which uses a reference KAP meter calibrated to measure the incident radiation, (ii) measurements using an energy-independent ionization chamber to correct for the energy dependence of the reference KAP meter, and (iii) Monte Carlo simulations of the beam quality correction factors that correct for differences between beam qualities at a standard laboratory and the clinic. The method was applied to the KAP meter in a Siemens Aristos FX plus unit. It was found that values reported by the built-in KAP meter differed from the more accurate values measured by the reference KAP meter by more than 25% for high tube voltages (more than 140 kV) and heavily filtered beams (0.3 mm Cu). Associated uncertainties were too high to claim that the IECs limit of 25% was exceeded. Nevertheless the differences were high enough to justify the need for a more accurate calibration of built-in KAP meters.

Place, publisher, year, edition, pages
IOP Publishing: Hybrid Open Access , 2014. Vol. 59, no 23, 7195-7210 p.
Keyword [en]
KAP-meter; kerma-area product; calibration
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:liu:diva-112993DOI: 10.1088/0031-9155/59/23/7195ISI: 000345254000010PubMedID: 25369212OAI: oai:DiVA.org:liu-112993DiVA: diva2:779177
Note

Funding Agencies|Swedish Radiation Safety Authority

Available from: 2015-01-12 Created: 2015-01-08 Last updated: 2017-12-05

Open Access in DiVA

fulltext(590 kB)82 downloads
File information
File name FULLTEXT01.pdfFile size 590 kBChecksum SHA-512
d02a75db255039a483075e758e4b0cd03dc9ad137624de38d3e44c821c1ee76722bee837f0bcef91396fc2e470b863c8c5210b5f7797cd4b196778e41ff1629b
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMed

Authority records BETA

Malusek, AlexandrHelmrot, EbbaSandborg, MichaelAlm Carlsson, Gudrun

Search in DiVA

By author/editor
Malusek, AlexandrHelmrot, EbbaSandborg, MichaelAlm Carlsson, Gudrun
By organisation
Division of Radiological SciencesFaculty of Health SciencesDepartment of Radiation PhysicsCenter for Medical Image Science and Visualization (CMIV)
In the same journal
Physics in Medicine and Biology
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 82 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 176 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf