Detection of the third heart sound using a tailored wavelet approach.
Linköping University, The Institute of Technology. Linköping University, Department of Biomedical Engineering, Physiological Measurements.
Linköping University, Department of Medicine and Care, Clinical Physiology. Linköping University, Faculty of Health Sciences. Östergötlands Läns Landsting, Heart and Medicine Center, Department of Clinical Physiology in Linköping.
Linköping University, Department of Biomedical Engineering, Physiological Measurements. Linköping University, The Institute of Technology.
2004 (English)In: Medical and Biological Engineering and Computing, ISSN 0140-0118, E-ISSN 1741-0444, Vol. 42, no 2, 253-258 p.Article in journal (Refereed) Published
Abstract [en]

The third heart sound is normally heard during auscultation of younger individuals but disappears with increasing age. However, this sound can appear in patients with heart failure and is thus of potential diagnostic use in these patients. Auscultation of the heart involves a high degree of subjectivity. Furthermore, the third heart sound has low amplitude and a low-frequency content compared with the first and second heart sounds, which makes it difficult for the human ear to detect this sound. It is our belief that it would be of great help to the physician to receive computer-based support through an intelligent stethoscope, to determine whether a third heart sound is present or not. A precise, accurate and low-cost instrument of this kind would potentially provide objective means for the detection of early heart failure, and could even be used in primary health care. In the first step, phonocardiograms from ten children, all known to have a third heart sound, were analysed, to provide knowledge about the sound features without interference from pathological sounds. Using this knowledge, a tailored wavelet analysis procedure was developed to identify the third heart sound automatically, a technique that was shown to be superior to Fourier transform techniques. In the second step, the method was applied to phonocardiograms from heart patients known to have heart failure. The features of the third heart sound in children and of that in patients were shown to be similar. This resulted in a method for the automatic detection of third heart sounds. The method was able to detect third heart sounds effectively (90%), with a low false detection rate (3.7%), which supports its clinical use. The detection rate was almost equal in both the children and patient groups. The method is therefore capable of detecting, not only distinct and clearly visible/audible third heart sounds found in children, but also third heart sounds in phonocardiograms from patients suffering from heart failure.

Place, publisher, year, edition, pages
2004. Vol. 42, no 2, 253-258 p.
National Category
Medical Laboratory and Measurements Technologies
Identifiers
URN: urn:nbn:se:liu:diva-116913PubMedID: 15125157OAI: oai:DiVA.org:liu-116913DiVA: diva2:801478
Available from: 2015-04-09 Created: 2015-04-09 Last updated: 2017-12-04

Open Access in DiVA

No full text

Other links

PubMedhttp://download-v2.springer.com/static/pdf/787/art%253A10.1007%252FBF02344639.pdf?token2=exp=1429521599~acl=%2Fstatic%2Fpdf%2F787%2Fart%25253A10.1007%25252FBF02344639.pdf*~hmac=56a985185178a7a30146a5e7c29ef784e7f984fd336e9a28f02e925ac614b062

Authority records BETA

Hult, PeterWranne, BengtAsk, Per

Search in DiVA

By author/editor
Hult, PeterWranne, BengtAsk, Per
By organisation
The Institute of TechnologyPhysiological MeasurementsClinical PhysiologyFaculty of Health SciencesDepartment of Clinical Physiology in Linköping
In the same journal
Medical and Biological Engineering and Computing
Medical Laboratory and Measurements Technologies

Search outside of DiVA

GoogleGoogle Scholar

pubmed
urn-nbn

Altmetric score

pubmed
urn-nbn
Total: 166 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf