Evaluating indoor environment of a retrofitted multi-family building with improved energy performance in Sweden
Linköping University, Department of Management and Engineering, Energy Systems. Linköping University, Faculty of Science & Engineering. University of Gavle, Sweden.
Linköping University, Department of Management and Engineering, Energy Systems. Linköping University, Faculty of Science & Engineering.
Linköping University, Department of Management and Engineering, Energy Systems. Linköping University, Faculty of Science & Engineering. University of Gavle, Sweden.
2015 (English)In: Energy and Buildings, ISSN 0378-7788, E-ISSN 1872-6178, Vol. 102, 32-44 p.Article in journal (Refereed) Published
Abstract [en]

The building sector within both the EU and Sweden accounts for about 40% of total energy use. It is therefore important to introduce energy efficiency measures in this sector in order to meet the national implementation of the Building Performance Directive. Retrofits that result in improved energy performance are important in order to meet national energy targets, but the impact on the indoor environment has to be considered. Properly chosen energy efficiency measures may affect the indoor environment positively. One retrofitted multi-family building, located in the city of Linkoping, Sweden, was chosen as the study object. The building represents a common type of construction in Sweden. This study presents an evaluation of both the indoor environment and energy use of the retrofitted building in comparison with a similar non-retrofitted building from the same area. The results show that the building has potential to reach a 39% reduction of space heating demand. The indoor environment has been improved compared to the non-retrofitted building. Adding external blinds from 15 May to 15 September between 10am-12pm on the east side and 12pm-3pm on the west side seems to be the best option for improving the indoor climate during summer. (c) 2015 Elsevier B.V. All rights reserved.

Place, publisher, year, edition, pages
Elsevier , 2015. Vol. 102, 32-44 p.
Keyword [en]
Multi-family building; Retrofit; Building energy simulation; Energy use; Indoor environment
National Category
Mechanical Engineering
Identifiers
URN: urn:nbn:se:liu:diva-120720DOI: 10.1016/j.enbuild.2015.05.021ISI: 000358458100003OAI: oai:DiVA.org:liu-120720DiVA: diva2:848279
Note

Funding Agencies|Swedish Energy Agency

Available from: 2015-08-24 Created: 2015-08-24 Last updated: 2015-08-24

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Liu, LinnRohdin, PatrikMoshfegh, Bahram
By organisation
Energy SystemsFaculty of Science & Engineering
In the same journal
Energy and Buildings
Mechanical Engineering

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 41 hits
ReferencesLink to record
Permanent link

Direct link