liu.seSearch for publications in DiVA
Change search
ReferencesLink to record
Permanent link

Direct link
Fluid absorption and the ethanol monitoring method
Linköping University, Department of Medical and Health Sciences, Division of Drug Research. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Anaesthetics, Operations and Specialty Surgery Center, Department of Anaesthesiology and Intensive Care in Linköping.
2015 (English)In: Acta Anaesthesiologica Scandinavica, ISSN 0001-5172, E-ISSN 1399-6576, Vol. 59, no 9, 1081-1093 p.Article, review/survey (Refereed) Published
Abstract [en]

BackgroundFluid absorption is a well-known complication of endoscopic surgeries, such as transurethral prostatic resection and transcervical endometrial resection. Absorption of electrolyte-free fluid in excess of 1L, which occurs in 5% to 10% of the operations, markedly increases the risk of adverse effects from the cardiovascular and neurological systems. Absorption of isotonic saline, which is used with the new bipolar resection technique, will change the scenario of adverse effects in a yet unknown way. Hyponatremia no longer occurs, but marking the saline with ethanol reveals that fluid absorption occurs just as much as with monopolar prostate resections. MethodsEthanol monitoring is a method for non-invasive indication and quantification of fluid absorption that has been well evaluated. By using an irrigating fluid that contains 1% of ethanol, updated information about fluid absorption can be obtained at any time perioperatively by letting the patient breathe into a hand-held alcolmeter. ResultsRegression equations and nomograms with variable complexity are available for estimating how much fluid has been absorbed, both when the alcolmeter is calibrated to show the blood ethanol level and when it is calibrated to show the breath ethanol concentration. Examples of how such estimations should be performed are given in this review article. ConclusionsThe difficulty is that the anesthesiologist must be aware of how the alcolmeter is calibrated (for blood or breath) and be able to distinguish between the intravascular and extravascular absorption routes, which give rise to different patterns and levels of breath ethanol concentrations.

Place, publisher, year, edition, pages
WILEY-BLACKWELL , 2015. Vol. 59, no 9, 1081-1093 p.
National Category
Clinical Medicine
Identifiers
URN: urn:nbn:se:liu:diva-121732DOI: 10.1111/aas.12550ISI: 000360982900001PubMedID: 25952458OAI: oai:DiVA.org:liu-121732DiVA: diva2:859354
Available from: 2015-10-06 Created: 2015-10-05 Last updated: 2015-10-06

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Hahn, Robert
By organisation
Division of Drug ResearchFaculty of Medicine and Health SciencesDepartment of Anaesthesiology and Intensive Care in Linköping
In the same journal
Acta Anaesthesiologica Scandinavica
Clinical Medicine

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 36 hits
ReferencesLink to record
Permanent link

Direct link