liu.seSearch for publications in DiVA
Change search
ReferencesLink to record
Permanent link

Direct link
Optimal phasor measurement unit placement for numerical observability in the presence of conventional measurements using semi-definite programming
National Technical University of Athens, Greece.
National Technical University of Athens, Greece.
National Technical University of Athens, Greece.
Linköping University, Department of Electrical Engineering, Automatic Control. Linköping University, Faculty of Science & Engineering.
2015 (English)In: IET Generation, Transmission & Distribution, ISSN 1751-8687, E-ISSN 1751-8695, Vol. 9, no 15, 2427-2436 p.Article in journal (Refereed) Published
Abstract [en]

This study presents a new approach for optimal placement of synchronised phasor measurement units (PMUs) to ensure complete power system observability in the presence of non-synchronous conventional measurements and zero injections. Currently, financial or technical restrictions prohibit the deployment of PMUs on every bus, which in turn motivates their strategic placement across the power system. PMU allocation is optimised here based on measurement observability criteria for achieving solvability of the power system state estimation. Most of the previous work has proposed topological observability based methods for optimal PMU placement (OPP), which may not always ensure numerical observability required for successful execution of state estimation. The proposed OPP method finds out the minimum number and the optimal locations of PMUs required to make the power system numerically observable. The problem is formulated as a binary semi-definite programming (BSDP) model, with binary decision variables, minimising a linear objective function subject to linear matrix inequality observability constraints. The BSDP problem is solved using an outer approximation scheme based on binary integer linear programming. The developed method is conducted on IEEE standard test systems. A large-scale system with 3120 buses is also analysed to exhibit the applicability of proposed model to practical power system cases.

Place, publisher, year, edition, pages
INST ENGINEERING TECHNOLOGY-IET , 2015. Vol. 9, no 15, 2427-2436 p.
Keyword [en]
phasor measurement; numerical analysis; state estimation; linear matrix inequalities; integer programming; linear programming; synchronised phasor measurement units; power system observability; power system state estimation; optimal PMU placement; OPP method; binary semidefinite programming model; BSDP model; linear matrix inequality; binary integer linear programming
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:liu:diva-123135DOI: 10.1049/iet-gtd.2015.0662ISI: 000364489400038OAI: oai:DiVA.org:liu-123135DiVA: diva2:877714
Available from: 2015-12-07 Created: 2015-12-04 Last updated: 2015-12-07

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Löfberg, Johan
By organisation
Automatic ControlFaculty of Science & Engineering
In the same journal
IET Generation, Transmission & Distribution
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle ScholarTotal: 1 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 263 hits
ReferencesLink to record
Permanent link

Direct link