liu.seSearch for publications in DiVA
Change search
ReferencesLink to record
Permanent link

Direct link
Fat Quantification in Skeletal Muscle Using Multigradient-Echo Imaging: Comparison of Fat and Water References
Skåne University Hospital, Sweden.
Linköping University, Department of Biomedical Engineering, Medical Informatics. Linköping University, Faculty of Science & Engineering. Linköping University, Center for Medical Image Science and Visualization (CMIV).
Lund University, Sweden.
Linköping University, Department of Medical and Health Sciences, Division of Radiological Sciences. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center for Surgery, Orthopaedics and Cancer Treatment, Department of Radiation Physics. Linköping University, Center for Medical Image Science and Visualization (CMIV).
Show others and affiliations
2016 (English)In: Journal of Magnetic Resonance Imaging, ISSN 1053-1807, E-ISSN 1522-2586, Vol. 43, no 1, 203-212 p.Article in journal (Refereed) PublishedText
Abstract [en]

Purpose: To investigate the precision, accuracy, and repeatability of water/fat imaging-based fat quantification in muscle tissue using a large flip angle (FA) and a fat reference for the calculation of the proton density fat fraction (FF). Comparison is made to a small FA water reference approach. Materials and Methods: An Intralipid phantom and both forearms of six patients suffering from lymphedema and 10 healthy volunteers were investigated at 1.5T. Two multigradient-echo sequences with eight echo times and FAs of 10 degrees and 85 degrees were acquired. For healthy volunteers, the acquisition of the right arm was performed twice with repositioning. From each set, water reference FF and fat reference FF images were reconstructed and the average FF and the standard deviation were calculated within the subfascial compartment. The small FA water reference was considered the reference standard. Results: A high agreement was found between the small FA water reference and large FA fat reference methods (FF bias=0.31%). In this study, the large FA fat reference approach also resulted in higher precision (38% smaller FF standard deviation in homogenous muscle tissue), but no significant difference in repeatability between the various methods was detected (coefficient of repeatability of small FA water reference approach 0.41%). Conclusion: The precision of fat quantification in muscle tissue can be increased with maintained accuracy using a larger flip angle, if a fat reference instead of a water reference is used.

Place, publisher, year, edition, pages
WILEY-BLACKWELL , 2016. Vol. 43, no 1, 203-212 p.
Keyword [en]
fat quantification; water; fat imaging; skeletal muscle; water reference; internal fat reference
National Category
Medical Biotechnology Clinical Medicine
Identifiers
URN: urn:nbn:se:liu:diva-125322DOI: 10.1002/jmri.24972ISI: 000368741400019PubMedID: 26095018OAI: oai:DiVA.org:liu-125322DiVA: diva2:906206
Note

Funding Agencies|Research Council of Southeast Sweden [FORSS-311941]; Knut and Alice Wallenberg Foundation; Stiftelsen for cancerforskning vid Onkologiska kliniken vid Universitetssjukhuset MAS; Skane County Councils Research and Development Foundation; Swedish Cancer Society; Allmanna Sjukhusets i Malmo Stiftelse for bekampande av cancer

Available from: 2016-02-24 Created: 2016-02-19 Last updated: 2016-02-24

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Romu, ThobiasDahlqvist Leinhard, Olof
By organisation
Medical InformaticsFaculty of Science & EngineeringCenter for Medical Image Science and Visualization (CMIV)Division of Radiological SciencesFaculty of Medicine and Health SciencesDepartment of Radiation Physics
In the same journal
Journal of Magnetic Resonance Imaging
Medical BiotechnologyClinical Medicine

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 1078 hits
ReferencesLink to record
Permanent link

Direct link