Point-of-care devices for physiological measurements in field conditions. A smorgasbord of instruments and validation procedures
Linköping University, Department of Physics, Chemistry and Biology, Biology. Linköping University, Faculty of Science & Engineering.
Linköping University, Department of Physics, Chemistry and Biology, Biology. Linköping University, Faculty of Science & Engineering.
2016 (English)In: Comparative Biochemistry and Physiology - Part A: Comparative Physiology, ISSN 0300-9629, no 16Article in journal (Refereed) In press
Abstract [en]

Point-of-care (POC) devices provide quick diagnostic results that increase the efficiency of patient care. Many POC devices are currently available to measure metabolites, blood gases, hormones, disease biomarkers or pathogens in samples as diverse as blood, urine, feces or exhaled breath. This diversity is potentially very useful for the comparative physiologist in field studies if proper validation studies are carried out to justify the accuracy of the devices in non-human species under different conditions. Our review presents an account of physiological parameters that can be monitored with POC devices and surveys the literature for suitable quantitative and statistical procedures for comparing POC measurements with reference “gold standard” procedures. We provide a set of quantitative tools and report on different correlation coefficients (Lin's Concordance Correlation Coefficient or the more widespread Pearson correlation coefficient), describe the graphical assessment of variation using Bland–Altman plots and discuss the difference between Model I and Model II regression procedures. We also report on three validation datasets for lactate, glucose and hemoglobin measurements in birds using the newly proposed procedures. We conclude the review with a haphazard account of future developments in the field, emphasizing the interest in lab-on-a-chip devices to carry out more complex experimental measurements than the ones currently available in POC devices.

Place, publisher, year, edition, pages
2016. no 16
National Category
Physiology
Identifiers
URN: urn:nbn:se:liu:diva-128105DOI: 10.1016/j.cbpa.2016.04.009PubMedID: 27083239OAI: oai:DiVA.org:liu-128105DiVA: diva2:928927
Available from: 2016-05-17 Created: 2016-05-17 Last updated: 2016-06-02

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Lindholm, CarolineAltimiras, Jordi
By organisation
BiologyFaculty of Science & Engineering
In the same journal
Comparative Biochemistry and Physiology - Part A: Comparative Physiology
Physiology

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 65 hits
ReferencesLink to record
Permanent link

Direct link