liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
The effect of flip-angle on body composition using calibrated water-fat MRI.
Linköping University, Department of Biomedical Engineering, Medical Informatics. Linköping University, Faculty of Science & Engineering. Linköping University, Center for Medical Image Science and Visualization (CMIV).
Linköping University, Department of Medical and Health Sciences. Linköping University, Faculty of Medicine and Health Sciences. Linköping University, Center for Medical Image Science and Visualization (CMIV).
Linköping University, Department of Clinical and Experimental Medicine, Division of Clinical Sciences. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center of Paediatrics and Gynaecology and Obstetrics, Department of Gynaecology and Obstetrics in Linköping.
Linköping University, Department of Medical and Health Sciences, Division of Physiotherapy. Linköping University, Faculty of Medicine and Health Sciences.ORCID iD: 0000-0002-1533-6872
Show others and affiliations
2016 (English)Conference paper, Poster (with or without abstract) (Other academic)
Abstract [en]

This study tested how the flip angle affects body composition analysis by MRI, if adipose tissue is used as an internal intensity reference. Whole-body water-fat images with flip angle 5° and 10° were collected from 29 women in an ongoing study. The images were calibrated based on the adipose tissue signal and whole-body total adipose, lean and soft tissue volumes were measured. A mean difference of 0.29 L, or 0.90 % of the average volume, and a coefficient of variation of 0.40 % was observed for adipose tissue.

Place, publisher, year, edition, pages
2016.
National Category
Radiology, Nuclear Medicine and Medical Imaging Medical Image Processing
Identifiers
URN: urn:nbn:se:liu:diva-128989OAI: oai:DiVA.org:liu-128989DiVA: diva2:933999
Conference
International Society for Magnetic Resonance in Medicine Annual Meeting & Exhibition, Singapore, May 7-13, 2016
Available from: 2016-06-07 Created: 2016-06-07 Last updated: 2016-06-22Bibliographically approved

Open Access in DiVA

No full text

Search in DiVA

By author/editor
Romu, ThobiasWest, JanneSpetz, Anna-ClaraLindblom, HannaLindh Åstrand, LottaHammar, MatsBorga, MagnusDahlqvist Leinhard, Olof
By organisation
Medical InformaticsFaculty of Science & EngineeringCenter for Medical Image Science and Visualization (CMIV)Department of Medical and Health SciencesFaculty of Medicine and Health SciencesDivision of Clinical SciencesDepartment of Gynaecology and Obstetrics in LinköpingDivision of PhysiotherapyDivision of Radiological SciencesDepartment of Radiation Physics
Radiology, Nuclear Medicine and Medical ImagingMedical Image Processing

Search outside of DiVA

GoogleGoogle Scholar

Total: 92 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf