liu.seSearch for publications in DiVA
Change search
Refine search result
1 - 9 of 9
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Rows per page
  • 5
  • 10
  • 20
  • 50
  • 100
  • 250
Sort
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
  • Disputation date (earliest first)
  • Disputation date (latest first)
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
  • Disputation date (earliest first)
  • Disputation date (latest first)
Select
The maximal number of hits you can export is 250. When you want to export more records please use the Create feeds function.
  • 1.
    Algmark, Carl
    et al.
    Linköping University, Department of Science and Technology, Media and Information Technology. Linköping University, The Institute of Technology.
    Eskilsson, Mattias
    Linköping University, Department of Science and Technology, Media and Information Technology. Linköping University, The Institute of Technology.
    Omgivningspåverkan vid sänkhammarborrning2014Independent thesis Basic level (university diploma), 20 credits / 30 HE creditsStudent thesis
    Abstract [en]

    Sänkhammarborrning är en metod som används för att utföra grundläggning med stålpålar. Metoden blir allt vanligare i Svenska tätbebyggda miljöer där krav ställs på låg omgivningspåverkan. Vid sänkhammarborrning borras ett foderrör av stål ner genom jordlagren till avsett djup, oftast till bärkraftigt berg. Foderröret lämnas sedan kvar, armeras, gjuts och utgör sedan själva pålen. Borrmaskinen består bland annat av en hammare som arbetar nere i hålet och drivs av antingen vatten eller luft. Borrföretagen har ofta tillgång till flera olika borrsystem men det saknas ibland underlag och forskning för hur olika borrsystem och metoder påverkar mark och omgivning vilket kan skapa en osäkerhet i projekteringsfasen och oförutsedda problem i utförandestadiet. Sänkhammarborrning anses ha en mindre massförträngande effekt men ger ändå en viss omgivningspåverkan både ovan och under mark. I den här studien har omgivningspåverkan under mark behandlats. Tre störningskällor har undersökts; vibrationer, uppspolning och trycksättning. Syftet har varit att teoretiskt undersöka hur vattendrivet- och luftdrivet sänkhammarborrsystem påverkar undergrunden i samband med att stålrörspålar installeras. För att nå syftet har en litteraturstudie och en intervjustudie genomförts. Även två fältbesök har gjorts. Litteratur och intervjuer har sedan analyserats med utgångspunkt i de tre nämnda fenomenen. Resultatet visar att de viktigaste faktorerna som påverkar hur stor omgivningspåverkan blir är markförutsättningar, maskinutrustning och utförandet. Vattendriven borrning visar sig löpa mindre risk att påverka omgivningen när det gäller uppspolning och trycksättning men om borrningen utförs på rätt sätt kan omgivningspåverkan undvikas även vid luftdriven borrning. De två borrsystemen har olika slagenergier och slagfrekvenser dock kan inga slutsatser dras av hur detta påverkar vibrationsnivåerna. Ett antal åtgärder finns för att minimera omgivningspåverkan, det handlar framförallt om att välja rätt borrsystem samt att borrningen utförs på rätt sätt.

  • 2. Andersson, R
    et al.
    Ask, Per
    Linköping University, Department of Biomedical Engineering, Physiological Measurements. Linköping University, The Institute of Technology.
    Force to restore the shape of an asymmetric extracorporeal tube as the basis for non-invasive pressure measurements.2002In: International Journal of Artificial Organs, ISSN 0391-3988, E-ISSN 1724-6040, Vol. 25, no 4, p. 281-289Article in journal (Refereed)
    Abstract [en]

    A zero-balance principle is described where intraluminal pressure is estimated from the counter force needed to restore the tube shape of an elastic extra corporeal tube. The aim was to optimise cross-sectional tube geometry for tube expansion due to pressure and to reduce the sensitivity to variation in mechanical tube characteristics using an experimental statistical and factorial design. The main application is pressure monitoring in blood and dialysate tubes during hemodialysis. Improving the monitoring of the dialysis process will reduce complications, such as sudden decreases in systemic blood pressure or occlusion at the artero-venous fistula. The factorial design indicated strong influence from the geometrical characteristics of the tube as well from the geometrical design parameters of the pressure transducer. We found a consistent relationship between the intraluminal pressure and the applied force needed to restore the tube shape. The modified cross-sectional tube geometry enhances measurement sensitivity and facilitates the desired behavior of tubes during pressure applications.

  • 3.
    Ask, Per
    et al.
    Linköping University, Department of Biomedical Engineering, Physiological Measurements. Linköping University, The Institute of Technology.
    Levitan, H
    Robinson, P J
    Rapoport, S I
    Peripheral nerve as an osmometer: role of the perineurium in frog sciatic nerve.1983In: American Journal of Physiology, ISSN 0002-9513, E-ISSN 2163-5773, Vol. 244, no 1, p. C75-81Article in journal (Refereed)
    Abstract [en]

    Measurements of volume and hydrostatic pressure in the frog sciatic nerve in vitro demonstrate that the nerve acts as an osmometer, in large part because the perineurium is a semipermeable membrane for water flow. Endoneurial hydrostatic pressure in nerves in isotonic Ringer exceeds bath pressure by about 7 mmHg. In Ringer made hypertonic by addition of sucrose, nerve volume and endoneurial pressure fall linearly in relation to 1/osmolality. The slope of the plot of pressure against volume provides a value for nerve compliance equal to 0.006 mm2/mmHg. Calculations based on the model of the nerve as an osmometer indicate that the nerve has an osmotically "inactive" volume equal to 0.19 mm3/mm, which is about 75% of the total volume of a nerve segment of unit length in normal Ringer. Perineurial hydraulic conductivity (Lp) equals 7.5 x 10(-13) cm3.s-1.dyn-1, a value characteristic of nonleaky epithelia. The perineurium is an elastic tissue with a constant modulus of elasticity equal to 3 x 10(6) dyn/cm2 when not markedly stretched and may limit nerve swelling under pathological conditions of nerve edema.

  • 4.
    Cleveson, Aron
    Linköping University, Department of Science and Technology, Media and Information Technology. Linköping University, The Institute of Technology.
    Sheet piling for permanent application in solid water hazards for construction of fishways.2014Independent thesis Basic level (university diploma), 20 credits / 30 HE creditsStudent thesis
    Abstract [en]

    När ett vattendrag regleras genom byggnation av dammar och vattenkraftverk skapas hinder, även så kallade vandringshinder för fiskar och andra vattenlevande organismer. Genom att bygga en fiskväg möjliggörs åter denna vandring. På senare år har det blivit vanligt att anlägga fiskvägar på ett naturligt sätt. Den senast framtagna metoden för att anlägga naturliga fiskvägar är att bygga ett så kallat inlöp. Inlöpet uppförs genom att en del av en damm skiljs av med hjälp av en skiljevägg som ansluts mot befintlig dammkonstruktion. Skiljeväggen kan utföras på flera sätt, ett av dess är genom att driva ner en kontinuerlig stålspont. Syftet med examensarbetet är att undersöka möjligheten att uppföra ett inlöp med hjälp av en tät kontinuerlig konsolspont av stål, i anslutning till befintlig dammkonstruktion. Målet med examensarbetet är att öka kunskapen vid användning av kontinuerlig stålspont för byggnation av fiskvägar i anslutning till befintliga dammkonstruktioner.

  • 5.
    Ghosh, Devanita
    et al.
    Linköping University, Department of Thematic Studies, Tema Environmental Change. Linköping University, Faculty of Arts and Sciences. Integrative Taxonomy and Microbial Ecology Research Group, Department of Biological Sciences, Indian Institute of Science Education and Research-Kolkata, Mohanpur, India.
    Routh, Joyanto
    Linköping University, Department of Thematic Studies, Tema Environmental Change. Linköping University, Faculty of Arts and Sciences.
    Bhadury, Punyasloke
    Integrative Taxonomy and Microbial Ecology Research Group, Department of Biological Sciences, Indian Institute of Science Education and Research-Kolkata, Mohanpur, India.
    Sub-surface Biogeochemical Characteristics and Its Effect on Arsenic Cycling in the Holocene Gray Sand Aquifers of the Lower Bengal Basin2017In: Frontiers in Environmental Science, ISSN 2296-665X, Vol. 5, article id 82Article in journal (Refereed)
    Abstract [en]

    High arsenic (As) content in the fertile delta plains of West Bengal has been widely reported since the 1990s. The shallow grey sand aquifers (GSA) deposited during the Holocene, are more commonly used as potable water sources, but they have high As levels. The release of As into groundwater is influenced by indigenous microbial communities metabolizing different organic carbon sources present in the GSA sediments. After pre-screening the groundwater for assessing their microbial phylogenetic diversity, two50-m deep boreholes were drilled in the GSAs, and 19 sediment samples were recovered from each core. In each of these samples, grain-size distribution, sequential extraction, and quantification of trace metals and total extractable lipids were analyzed. The aquifer sediments consisted of medium to fine micaceous sand with clay lenses in between them; a thick clay layer occurred on top of both boreholes. Arsenic concentration in these sediments varied from 1.80 to 41.0 mg/kg and was mostly associated with the oxide and silicate-rich crystalline minerals. Arsenic showed a significant correlation with Fe in all fractions, suggesting the presence of Fe-(oxy)-hydroxides bound As minerals. The diagnostic lipid biomarkers showed presence of compounds derived from higher plants (epicuticular waxes) and microbial inputs. The biomarkers were abundant in clay and silt-rich layers. The samples indicated preferential preservation of n-alkanes over other functional compounds (e.g. alcohols and fatty acids), that are more reactive, and hence subject to further degradation. Sediments recovered from the borehole indicated the presence of Eustigmatophytes and vascular plant waxes that are mostly surface-derived. The sedimentary lipids also indicated the presence of complex petroleum-derived hydrocarbons. These compounds provide organic substrates, and support the preferential survival of specific microbial communities in these sediments.

  • 6.
    Gustafson, Ellen
    et al.
    Linköping University, Department of Science and Technology, Communications and Transport Systems. Linköping University, The Institute of Technology.
    Strömgren, Emelie
    Linköping University, Department of Science and Technology, Communications and Transport Systems. Linköping University, The Institute of Technology.
    Cone Penetration Test - a comparative study of the equipment and the performance2015Independent thesis Basic level (university diploma), 20 credits / 30 HE creditsStudent thesis
    Abstract [en]

    Inom geotekniken behövs ofta jordlagerföljden och jordens egenskaper bedömmas. För att göra detta används ofta sonderingsmetoden Cone Penetration Test (CPT), som används främst till att ge en preliminär bedömning av jordlagerföljden och en uppskattning av geotekniska egenskaper. CPT-sondering är en avancerad metod som ställer högre krav på både fältgeotekniker och handläggande geotekniker jämfört med andra metoder och är en metod där många faktorer påverkar resultatet. Detta examensarbete undersöker vilka faktorer som påverkar CPT-sondering med fokus på utrustning och handhavandet hos teknikkonsultföretaget WSP i Östergötland. Syftet med arbetet är att jämföra och utvärdera metod och resultat hos WSP för att se om det finns några skillnader i handhavandet och mellan de tre olika sonderna som är använda i studien. I studien utfördes 12 stycken CPT-sonderingar i samma område och dessa utfördes av samma fältgeotekniker, där häften av sonderingarna var utförda med förborrning och vattenfyllt sonderingshål och den andra hälften utförda med endast förborrning. Dessutom utfördes en skruvprovtagning i området. När sonderingarna var gjorda utvärderades resultaten i programvaran Conrad. Sonderingarna utfördes i ett område mellan Vånga och Göten, väster om Norrköping och området består främst av silt med lager av sand. Resultatet av studien visar att sond A har de jämnaste resultaten och orsaken till detta är troligtvis att denna sond är den som senast har kalibrerats. Efter sondering 2-C upptäcktes en skada på friktionshylsan för sond C, friktionshylsan byttes ut och trots detta ser resultatet för denna sond bra ut. Den första sonderingen gjord efter byte av friktionshylsan avviker dock i resultatet jämfört med de andra sonderingarna gjorda med sond C. Resultatet från sond B visar att denna sond uppnår lägre värde jämfört med de andra sonderna. En orsak till detta anses vara att denna sond är den sond som är kalibrerad med det tidigaste datumet. Slutsatsen i studien är att de faktorer som påverkar resultatet mest är kalibrering, att sonden är vätskemättad och att kontroller har utförts av sonden innan och efter sonderingen.

  • 7.
    Routh, Joyanto
    Department of Earth Sciences, University of Roorkee, Roorkee 247667, India.
    Metamorphism and Structural Interpretation of the Zanskar Shear Zone, PJW Himalaya, India1993In: Journal of the Geological Society of India, ISSN 0016-7622, E-ISSN 0974-6889, Vol. 41, no 3, p. 187-198Article in journal (Refereed)
    Abstract [en]

    Herren in 1987, reported normal faults resulted in the telescoping of metamorphic isograds within a 200 meter zone between Sumche Topko to Mulung Topko in the Zanskar Shear Zone NW Himalaya. However petrographic study-of sections obtained from Mulung Topko and surrounding areas (pensila-padarn section) indicate that the rocks belong to the kyanite-sillimanite-starurolite grade only. Extension crenulation cleavage and other shear criteria show an initial NESW movement after which a layer parallel extension occurred and the shear zone developed. Minieralogical assemblage and mapping indicate that the isograds run paralleI to each other before they possibly truncate against the shear zone along the Pensila-Padam section. A probable model has been proposed to explain the features

  • 8.
    Sollander, Joel
    et al.
    Linköping University, Department of Science and Technology, Communications and Transport Systems. Linköping University, The Institute of Technology.
    Svensson, Marcus
    Linköping University, Department of Science and Technology, Communications and Transport Systems. Linköping University, The Institute of Technology.
    Friktion mellan mobil vattenbarriär och mark2018Independent thesis Basic level (university diploma), 20 credits / 30 HE creditsStudent thesis
    Abstract [en]

    Översvämningar är en naturkatastrof som uppkommer vid stor variation i vattentillförsel, exempelvis vid regn eller snösmältning. Detta är ett problem som man länge har bekämpat genom att bygga upp barriärer för att hålla vattnet borta. Tidigare har barriärerna vanligen byggts av sandsäckar, men under de senaste decennierna har många alternativ utvecklats för att göra uppbyggandet enklare och effektivare. Geodesign Barriers AB är ett företag som utvecklat mobila vattenbarriärer med syftet att vara snabba och enkla att montera samt platseffektiv när den inte används. Barriären är utvecklad för att kunna klara stora vattentryck, men vissa markförhållanden ställer högre krav på konstruktionen. Därför har man utvecklat två komplement som ökar barriärens kapacitet. Det ena är förankringsstag som förankras i marken och det andra är en skopa som monteras på barriärens undersida. Syftet har varit att med hjälp av tester i fält, ta reda på när respektive komplement bör användas på den undersökta modellen EUR125.

  • 9. Ödman, Svante
    et al.
    Levitan, Herbert
    Robinson, Peter J
    Michel, Mary Ellen
    Ask, Per
    Linköping University, Department of Biomedical Engineering, Physiological Measurements. Linköping University, The Institute of Technology.
    Rapoport, Santley I
    Peripheral nerve as an osmometer: role of endoneurial capillaries in frog sciatic nerve.1987In: American Journal of Physiology, ISSN 0002-9513, E-ISSN 2163-5773, Vol. 252, no 3 Pt 1, p. C335-41Article in journal (Refereed)
    Abstract [en]

    The sciatic nerve of the frog was perfused in vivo with isotonic Ringer solution followed by Ringer made hypertonic by addition of sucrose or of NaCl. Nerve diameter and endoneurial hydrostatic pressure fell during hypertonic Ringer perfusion. Using a model that describes the elastic and osmotic properties of the nerve, sigma sLp, the product of the osmotic reflection coefficient at endoneurial capillaries for s equals sucrose or NaCl (which approximates 1), and of capillary hydraulic conductivity, was found to equal 73 X 10(-13) cm3 X s-1 X dyn-1. The nerve is elastic. It has a compliance K of 3.7 X 10(-5) cm2 X mmHg-1, corresponding to a modulus of elasticity E of the perineurium equal to 1.2 X 10(6) dyn X cm-2. The results indicate that the nerve behaves as an osmometer during vascular perfusion, due to the low permeability of endoneurial capillaries to small solutes such as NaCl and sucrose. A low capillary hydraulic conductivity limits bulk water flow between blood and nerve, and a low compliance limits nerve swelling and edema.

1 - 9 of 9
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf