liu.seSearch for publications in DiVA
Endre søk
Begrens søket
1234 101 - 150 of 152
RefereraExporteraLink til resultatlisten
Permanent link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Treff pr side
  • 5
  • 10
  • 20
  • 50
  • 100
  • 250
Sortering
  • Standard (Relevans)
  • Forfatter A-Ø
  • Forfatter Ø-A
  • Tittel A-Ø
  • Tittel Ø-A
  • Type publikasjon A-Ø
  • Type publikasjon Ø-A
  • Eldste først
  • Nyeste først
  • Skapad (Eldste først)
  • Skapad (Nyeste først)
  • Senast uppdaterad (Eldste først)
  • Senast uppdaterad (Nyeste først)
  • Disputationsdatum (tidligste først)
  • Disputationsdatum (siste først)
  • Standard (Relevans)
  • Forfatter A-Ø
  • Forfatter Ø-A
  • Tittel A-Ø
  • Tittel Ø-A
  • Type publikasjon A-Ø
  • Type publikasjon Ø-A
  • Eldste først
  • Nyeste først
  • Skapad (Eldste først)
  • Skapad (Nyeste først)
  • Senast uppdaterad (Eldste først)
  • Senast uppdaterad (Nyeste først)
  • Disputationsdatum (tidligste først)
  • Disputationsdatum (siste først)
Merk
Maxantalet träffar du kan exportera från sökgränssnittet är 250. Vid större uttag använd dig av utsökningar.
  • 101.
    Lantz, Jonas
    et al.
    Linköpings universitet, Institutionen för teknik och naturvetenskap, Medie- och Informationsteknik. Linköpings universitet, Tekniska högskolan.
    Dyverfeldt, Petter
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Institutionen för teknik och naturvetenskap, Medie- och Informationsteknik.
    Improving Blood Flow Simulations by Incorporating Measured Subject-Specific Wall Motion2014Inngår i: Cardiovascular Engineering and Technology, ISSN 1869-408X, E-ISSN 1869-4098, Vol. 5, nr 3, s. 261-269Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Physiologically relevant simulations of blood flow require models that allow for wall deformation. Normally a fluid–structure interaction (FSI) approach is used; however, this method relies on several assumptions and patient-specific material parameters that are difficult or impossible to measure in vivo. In order to circumvent the assumptions inherent in FSI models, aortic wall motion was measured with MRI and prescribed directly in a numerical solver. In this way is not only the displacement of the vessel accounted for, but also the interaction with the beating heart and surrounding organs. In order to highlight the effect of wall motion, comparisons with standard rigid wall models was performed in a healthy human aorta. The additional computational cost associated with prescribing the wall motion was low (17%). Standard hemodynamic parameters such as time-averaged wall shear stress and oscillatory shear index seemed largely unaffected by the wall motion, as a consequence of the smoothing effect inherent in time-averaging. Conversely, instantaneous wall shear stress was greatly affected by the wall motion; the wall dynamics seemed to produce a lower wall shear stress magnitude compared to a rigid wall model. In addition, it was found that if wall motion was taken into account the computed flow field agreed better with in vivo measurements. This article shows that it is feasible to include measured subject-specific wall motion into numerical simulations, and that the wall motion greatly affects the flow field. This approach to incorporate measured motion should be considered in future studies of arterial blood flow simulations.

  • 102.
    Lantz, Jonas
    et al.
    Linköpings universitet, Institutionen för teknik och naturvetenskap, Medie- och Informationsteknik. Linköpings universitet, Tekniska högskolan.
    Ebbers, Tino
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    A new method for obtaining high-resolution velocity data from magnetic resonance imaging?2013Konferansepaper (Annet vitenskapelig)
  • 103.
    Lantz, Jonas
    et al.
    Linköpings universitet, Institutionen för teknik och naturvetenskap, Medie- och Informationsteknik. Linköpings universitet, Tekniska högskolan.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Incorporating MRI-Measured Arterial Wall Motion in Numerical Simulations2014Konferansepaper (Annet vitenskapelig)
  • 104.
    Lantz, Jonas
    et al.
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Tekniska högskolan.
    Ebbers, Tino
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Engvall, Jan
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Karlsson, Matts
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Tekniska högskolan.
    Large Eddy Simulation of Aortic Coarctation Before and After Surgery2012Konferansepaper (Fagfellevurdert)
  • 105.
    Lantz, Jonas
    et al.
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Tekniska högskolan.
    Ebbers, Tino
    Linköpings universitet, Institutionen för teknik och naturvetenskap, Medie- och Informationsteknik. Linköpings universitet, Tekniska högskolan. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Engvall, Jan
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Karlsson, Matts
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Tekniska högskolan.
    Numerical and experimental assessment of turbulent kinetic energy in an aortic coarctation2013Inngår i: Journal of Biomechanics, ISSN 0021-9290, E-ISSN 1873-2380, Vol. 46, nr 11, s. 1851-1858Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    The turbulent blood flow through an aortic coarctation in a 63-year old female patient was studied experimentally using magnetic resonance imaging (MRI), and numerically using computational fluid dynamics (CFD), before and after catheter intervention. Turbulent kinetic energy (TKE) was computed in the numerical model using large eddy simulation and compared with direct in vivo MRI measurements. Despite the two totally different methods to obtain TKE values, both quantitative and qualitative results agreed very well. The results showed that even though both blood flow rate and Reynolds number increased after intervention, total turbulent kinetic energy levels decreased in the coarctation. Therefore, the use of the Reynolds number alone as a measure of turbulence in cardiovascular flows should be used with caution. Furthermore, the change in flow field and kinetic energy were assessed, and it was found that before intervention a jet formed in the throat of the coarctation, which impacted the arterial wall just downstream the constriction. After intervention the jet was significantly weaker and broke up almost immediately, presumably resulting in less stress on the wall. As there was a good agreement between measurements and numerical results (the increase and decrease of integrated TKE matched measurements almost perfectly while peak values differed by approximately 1 mJ), the CFD results confirmed the MRI measurements while at the same time providing high-resolution details about the flow. Thus, this preliminary study indicates that MR-based TKE measurements might be useful as a diagnostic tool when evaluating intervention outcome, while the detailed numerical results might be useful for further understanding of the flow for treatment planning.

  • 106.
    Lantz, Jonas
    et al.
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Tekniska högskolan.
    Ebbers, Tino
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Engvall, Jan
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Karlsson, Matts
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Tekniska högskolan.
    Validation of Turbulent Kinetic Energy in an Aortic Coarctation Before and After Intervention – MRI vs. CFD2013Inngår i: J Cardiovasc Magn Reson. 2013; 15(Suppl 1): E46, 2013Konferansepaper (Annet vitenskapelig)
  • 107.
    Lantz, Jonas
    et al.
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Tekniska högskolan.
    Ebbers, Tino
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Karlsson, Matts
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Tekniska högskolan.
    Quantifying Turbulent Kinetic Energy in an Aortic Coarctation with Large Eddy Simulation and Magnetic Resonance Imaging2012Konferansepaper (Fagfellevurdert)
  • 108.
    Lantz, Jonas
    et al.
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Gupta, Vikas
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Henriksson, Lilian
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Karlsson, Matts
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Tekniska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Persson, Anders
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Region Östergötland, Diagnostikcentrum, Röntgenkliniken i Linköping.
    Carlhäll, Carljohan
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Characterization of Cardiac Flow in Heart Disease Patients by CFD and 4D Flow MRI2017Inngår i: Bulletin of the Amerian Physcial Society, American Physical Society, 2017Konferansepaper (Fagfellevurdert)
    Abstract [en]

    In this study, cardiac blood flow was simulated using Computational Fluid Dynamics and compared to in vivo flow measurements by 4D Flow MRI. In total, nine patients with various heart diseases were studied. Geometry and heart wall motion for the simulations were obtained from clinical CT measurements, with 0.3x0.3x0.3 mm spatial resolution and 20 time frames covering one heartbeat. The CFD simulations included pulmonary veins, left atrium and ventricle, mitral and aortic valve, and ascending aorta. Mesh sizes were on the order of 6-16 million cells, depending on the size of the heart, in order to resolve both papillary muscles and trabeculae. The computed flow field agreed visually very well with 4D Flow MRI, with characteristic vortices and flow structures seen in both techniques. Regression analysis showed that peak flow rate as well as stroke volume had an excellent agreement for the two techniques. We demonstrated the feasibility, and more importantly, fidelity of cardiac flow simulations by comparing CFD results to in vivo measurements. Both qualitative and quantitative results agreed well with the 4D Flow MRI measurements. Also, the developed simulation methodology enables “what if” scenarios, such as optimization of valve replacement and other surgical procedures.

  • 109.
    Lantz, Jonas
    et al.
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Gupta, Vikas
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Henriksson, Lilian
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Karlsson, Matts
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Tekniska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Persson, Anders
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Diagnostikcentrum, Röntgenkliniken i Linköping.
    Carlhäll, Carljohan
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    First Results of CT-derived Cardiac 4D Blood Flow - Comparison With 4D Flow MRI2017Konferansepaper (Annet vitenskapelig)
  • 110.
    Lantz, Jonas
    et al.
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Gupta, Vikas
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Medicinska fakulteten.
    Henriksson, Lilian
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Karlsson, Matts
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Tekniska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Persson, Anders
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Diagnostikcentrum, Röntgenkliniken i Linköping. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Carlhäll, Carl-Johan
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Medicinska fakulteten.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Impact of Pulmonary Venous Inflow on Cardiac Flow Simulations: Comparison with In Vivo 4D Flow MRI2019Inngår i: Annals of Biomedical Engineering, ISSN 0090-6964, E-ISSN 1573-9686, Vol. 47, nr 2, s. 413-424Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Blood flow simulations are making their way into the clinic, and much attention is given to estimation of fractional flow reserve in coronary arteries. Intracardiac blood flow simulations also show promising results, and here the flow field is expected to depend on the pulmonary venous (PV) flow rates. In the absence of in vivo measurements, the distribution of the flow from the individual PVs is often unknown and typically assumed. Here, we performed intracardiac blood flow simulations based on time-resolved computed tomography on three patients, and investigated the effect of the distribution of PV flow rate on the flow field in the left atrium and ventricle. A design-of-experiment approach was used, where PV flow rates were varied in a systematic manner. In total 20 different simulations were performed per patient, and compared to in vivo 4D flow MRI measurements. Results were quantified by kinetic energy, mitral valve velocity profiles and root-mean-square errors of velocity. While large differences in atrial flow were found for varying PV inflow distributions, the effect on ventricular flow was negligible, due to a regularizing effect by mitral valve. Equal flow rate through all PVs most closely resembled in vivo measurements and is recommended in the absence of a priori knowledge.

  • 111.
    Lantz, Jonas
    et al.
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Gupta, Vikas
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Henriksson, Lilian
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Region Östergötland, Diagnostikcentrum, Röntgenkliniken i Linköping. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Medicinska fakulteten.
    Karlsson, Matts
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Tekniska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Persson, Anders
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Diagnostikcentrum, Röntgenkliniken i Linköping. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Carlhäll, Carljohan
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Intracardiac Flow at 4D CT: Comparison with 4D Flow MRI2018Inngår i: Radiology, ISSN 0033-8419, E-ISSN 1527-1315, Vol. 289, nr 1, s. 51-58Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Purpose

    To investigate four-dimensional (4D) flow CT for the assessment of intracardiac blood flow patterns as compared with 4D flow MRI.

    Materials and Methods

    This prospective study acquired coronary CT angiography and 4D flow MRI data between February and December 2016 in a cohort of 12 participants (age range, 36–74 years; mean age, 57 years; seven men [age range, 36–74 years; mean age, 57 years] and five women [age range, 52–73 years; mean age, 64 years]). Flow simulations based solely on CT-derived cardiac anatomy were assessed together with 4D flow MRI measurements. Flow patterns, flow rates, stroke volume, kinetic energy, and flow components were quantified for both techniques and were compared by using linear regression.

    Results

    Cardiac flow patterns obtained by using 4D flow CT were qualitatively similar to 4D flow MRI measurements, as graded by three independent observers. The Cohen κ score was used to assess intraobserver variability (0.83, 0.79, and 0.70) and a paired Wilcoxon rank-sum test showed no significant change (P > .05) between gradings. Peak flow rate and stroke volumes between 4D flow MRI measurements and 4D flow CT measurements had high correlation (r = 0.98 and r = 0.81, respectively; P < .05 for both). Integrated kinetic energy quantified at peak systole correlated well (r = 0.95, P < .05), while kinetic energy levels at early and late filling showed no correlation. Flow component analysis showed high correlation for the direct and residual components, respectively (r = 0.93, P < .05 and r = 0.87, P < .05), while the retained and delayed components showed no correlation.

    Conclusion

    Four-dimensional flow CT produced qualitatively and quantitatively similar intracardiac blood flow patterns compared with the current reference standard, four-dimensional flow MRI.

  • 112.
    Lantz, Jonas
    et al.
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Henriksson, Lilian
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Region Östergötland, Diagnostikcentrum, Röntgenkliniken i Linköping.
    Persson, Anders
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Diagnostikcentrum, Röntgenkliniken i Linköping.
    Karlsson, Matts
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Tekniska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Ebbers, Tino
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Importance Of Including Papillary Muscles And Trabeculae In Cardiac Flow Simulations2016Inngår i: Proceedings of the 2016 Summer Biomechanics, Bioengineering and Biotransport Conference, Organizing Committee for the 2016 Summer Biomechanics, Bioengineering and Biotransport , 2016Konferansepaper (Annet vitenskapelig)
  • 113.
    Lantz, Jonas
    et al.
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Medicinska fakulteten.
    Henriksson, Lilian
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Persson, Anders
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Diagnostikcentrum, Röntgenkliniken i Linköping.
    Karlsson, Matts
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Tekniska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Ebbers, Tino
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Patient-Specific Simulation of Cardiac Blood Flow From High-Resolution Computed Tomography2016Inngår i: Journal of Biomechanical Engineering, ISSN 0148-0731, E-ISSN 1528-8951, Vol. 138, nr 12Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Cardiac hemodynamics can be computed from medical imaging data, and results could potentially aid in cardiac diagnosis and treatment optimization. However, simulations are often based on simplified geometries, ignoring features such as papillary muscles and trabeculae due to their complex shape, limitations in image acquisitions, and challenges in computational modeling. This severely hampers the use of computational fluid dynamics in clinical practice. The overall aim of this study was to develop a novel numerical framework that incorporated these geometrical features. The model included the left atrium, ventricle, ascending aorta, and heart valves. The framework used image registration to obtain patient-specific wall motion, automatic remeshing to handle topological changes due to the complex trabeculae motion, and a fast interpolation routine to obtain intermediate meshes during the simulations. Velocity fields and residence time were evaluated, and they indicated that papillary muscles and trabeculae strongly interacted with the blood, which could not be observed in a simplified model. The framework resulted in a model with outstanding geometrical detail, demonstrating the feasibility as well as the importance of a framework that is capable of simulating blood flow in physiologically realistic hearts.

  • 114.
    Markl, Michael
    et al.
    University Hospital Freiburg.
    Kilner, Philip J
    Royal Brompton .
    Ebbers, Tino
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Fysiologi. Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära.
    Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance2011Inngår i: JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, ISSN 1097-6647, Vol. 13, nr 7Artikkel, forskningsoversikt (Fagfellevurdert)
    Abstract [en]

    Background: Phase contrast cardiovascular magnetic resonance (CMR) is able to measure all three directional components of the velocities of blood flow relative to the three spatial dimensions and the time course of the heart cycle. In this article, methods used for the acquisition, visualization, and quantification of such datasets are reviewed and illustrated. Methods: Currently, the acquisition of 3D cine (4D) phase contrast velocity data, synchronized relative to both cardiac and respiratory movements takes about ten minutes or more, even when using parallel imaging and optimized pulse sequence design. The large resulting datasets need appropriate post processing for the visualization of multidirectional flow, for example as vector fields, pathlines or streamlines, or for retrospective volumetric quantification. Applications: Multidirectional velocity acquisitions have provided 3D visualization of large scale flow features of the healthy heart and great vessels, and have shown altered patterns of flow in abnormal chambers and vessels. Clinically relevant examples include retrograde streams in atheromatous descending aortas as potential thromboembolic pathways in patients with cryptogenic stroke and marked variations of flow visualized in common aortic pathologies. Compared to standard clinical tools, 4D velocity mapping offers the potential for retrospective quantification of flow and other hemodynamic parameters. Conclusions: Multidirectional, 3D cine velocity acquisitions are contributing to the understanding of normal and pathologically altered blood flow features. Although more rapid and user-friendly strategies for acquisition and analysis may be needed before 4D velocity acquisitions come to be adopted in routine clinical CMR, their capacity to measure multidirectional flows throughout a study volume has contributed novel insights into cardiovascular fluid dynamics in health and disease.

  • 115.
    Modin, Daniel
    et al.
    Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet.
    Renner, Johan
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Tekniska högskolan.
    Gårdhagen, Roland
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Tekniska högskolan.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Länne, Toste
    Linköpings universitet, Institutionen för medicin och hälsa, Fysiologi. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Thorax-kärlkliniken i Östergötland.
    Karlsson, Matts
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Tekniska högskolan.
    Evaluation of Aortic Geometries created by MRI Data in Man2011Inngår i: Clinical Physiology and Functional Imaging, ISSN 1475-0961, E-ISSN 1475-097X, Vol. 31, nr 6, s. 485-491Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    The development of atherosclerotic plaques has been associated with the patterns of wall shear stress (WSS). However, much is still uncertain with the methods used to calculate WSS. Correct vessel geometries are mandatory to get reliable estimations and the purpose of this study was to evaluate an in vivo method for creating aortic 3D geometry in man based on data from magnetic resonance imaging (MRI) with ultrasound as reference.

    Methods: The aortas of ten healthy males, 23.4 ± 1.6 years of age, were examined with MRI, and 3D geometries were created with manual segmentation of the images. Lumen diameters (LD) were measured in the abdominal aorta (AA) and the thoracic aorta (TA) with non-invasive B-mode ultrasound as a reference.

    Results: The anteroposterior diameter of the AA was 13.6 ± 1.1 mm for the MRI and 13.8 ± 1.3 mm for the ultrasound (NS). Intraobserver variability (CV) for MRI and ultrasound was <0.92% and <0.40% respectively . Interobserver variability MRI and ultrasound was 0.96% and 0.56% respectively. The diameter of the TA was 19.2 ± 1.4 mm for the MRI, and the intraobserver variability (CV) were <0.78% and interobserver variability (CV) were 0.92%.

    Conclusion: Specific arterial geometries can be constructed with a high degree of accuracy using MRI. This indicate that the MRI geometries may be used to create realistic and correct geometries in the calculation of WSS in the aorta of man.

  • 116.
    Peolsson, Anneli
    et al.
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för fysioterapi. Linköpings universitet, Medicinska fakulteten.
    Karlsson, Anette
    Linköpings universitet, Institutionen för medicinsk teknik, Avdelningen för medicinsk teknik. Linköpings universitet, Tekniska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Ghafouri, Bijar
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för samhällsmedicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Sinnescentrum, Smärt och rehabiliteringscentrum.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Engström, Maria
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Jönsson, Margaretha
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för fysioterapi. Linköpings universitet, Medicinska fakulteten. Herrgardets Vardcentral, Sweden.
    Wåhlén, Karin
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för samhällsmedicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Sinnescentrum, Smärt och rehabiliteringscentrum.
    Romu, Thobias
    Linköpings universitet, Institutionen för medicinsk teknik. Linköpings universitet, Tekniska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Borga, Magnus
    Linköpings universitet, Institutionen för medicinsk teknik, Avdelningen för medicinsk teknik. Linköpings universitet, Tekniska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Kristjansson, Eythor
    Univ Iceland, Iceland.
    Bahat, Hilla Sarig
    Univ Haifa, Israel.
    German, Dmitry
    Univ Haifa, Israel.
    Zsigmond, Peter
    Linköpings universitet, Institutionen för klinisk och experimentell medicin, Avdelningen för neuro- och inflammationsvetenskap. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Sinnescentrum, Neurokirurgiska kliniken US.
    Peterson, Gunnel
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för fysioterapi. Linköpings universitet, Medicinska fakulteten. Uppsala Univ, Sweden.
    Pathophysiology behind prolonged whiplash associated disorders: study protocol for an experimental study2019Inngår i: BMC Musculoskeletal Disorders, ISSN 1471-2474, E-ISSN 1471-2474, Vol. 20, artikkel-id 51Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    BackgroundThere is insufficient knowledge of pathophysiological parameters to understand the mechanism behind prolonged whiplash associated disorders (WAD), and it is not known whether or not changes can be restored by rehabilitation. The aims of the projects are to investigate imaging and molecular biomarkers, cervical kinaesthesia, postural sway and the association with pain, disability and other outcomes in individuals with longstanding WAD, before and after a neck-specific exercise intervention. Another aim is to compare individuals with WAD with healthy controls.MethodsParticipants are a sub-group (n=30) of individuals recruited from an ongoing randomized controlled study (RCT). Measurements in this experimental prospective study will be carried out at baseline (before intervention) and at a three month follow-up (end of physiotherapy intervention), and will include muscle structure and inflammation using magnetic resonance imaging (MRI), brain structure and function related to pain using functional MRI (fMRI), muscle function using ultrasonography, biomarkers using samples of blood and saliva, cervical kinaesthesia using the butterfly test and static balance test using an iPhone app. Association with other measures (self-reported and clinical measures) obtained in the RCT (e.g. background data, pain, disability, satisfaction with care, work ability, quality of life) may be investigated. Healthy volunteers matched for age and gender will be recruited as controls (n=30).DiscussionThe study results may contribute to the development of improved diagnostics and improved rehabilitation methods for WAD.Trial registrationClinicaltrial.gov Protocol ID: NCT03664934, initial release 09/11/2018.

  • 117.
    Petersson, Sven
    et al.
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Hälsouniversitetet.
    Dyverfeldt, Petter
    Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Assessment of the accuracy of MRI wall shear stress estimation using numerical simulations2012Inngår i: Journal of Magnetic Resonance Imaging, ISSN 1053-1807, E-ISSN 1522-2586, Vol. 36, nr 1, s. 128-138Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Purpose: To investigate the accuracy of wall shear stress (WSS) estimation using MRI. Specifically, to investigate the impact of different parameters and if MRI WSS estimates are monotonically related to actual WSS. Materials and Methods: The accuracy of WSS estimation using methods based on phase-contrast (PC) MRI velocity mapping, Fourier velocity encoding (FVE) and intravoxel velocity standard deviation mapping were studied using numerical simulations. The influence of spatial resolution, velocity encoding, wall segmentation, and voxel location were investigated over a range of WSS values. Results: WSS estimates were found to be sensitive to parameter settings in general and spatial resolution in particular. All methods underestimated WSS, except for the FVE-based method, which instead was extremely sensitive to voxel position relative to the wall. Methods using PC-based WSS estimation with wall segmentation showed to be accurate for low WSS, but were sensitive to segmentation errors. Conclusion: Even in the absence of noise and for relatively simple velocity profiles, MRI WSS estimates cannot always be assumed to be linearly or even monotonically related to actual WSS. High WSS values cannot be resolved and the estimates depend on parameter setting. Nevertheless, distinguishing areas of low and moderate WSS may be feasible.

  • 118.
    Petersson, Sven
    et al.
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Hälsouniversitetet.
    Dyverfeldt, Petter
    Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Gårdhagen, Roland
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Tekniska högskolan.
    Karlsson, Matts
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Tekniska högskolan.
    Ebbers, Tino
    Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Fysiologi. Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära.
    Simulation of phase contrast MRI of turbulent flow2010Inngår i: Magnetic Resonance in Medicine, ISSN 0740-3194, E-ISSN 1522-2594, Vol. 64, nr 4, s. 1039-1046Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Phase contrast MRI is a powerful tool for the assessment of blood flow. However, especially in the highly complex and turbulent flow that accompanies many cardiovascular diseases, phase contrast MRI may suffer from artifacts. Simulation of phase contrast MRI of turbulent flow could increase our understanding of phase contrast MRI artifacts in turbulent flows and facilitate the development of phase contrast MRI methods for the assessment of turbulent blood flow. We present a method for the simulation of phase contrast MRI measurements of turbulent flow. The method uses an Eulerian-Lagrangian approach, in which spin particle trajectories are computed from time-resolved large eddy simulations. The Bloch equations are solved for each spin for a frame of reference moving along the spins trajectory. The method was validated by comparison with phase contrast MRI measurements of velocity and intravoxel velocity standard deviation (IVSD) on a flow phantom consisting of a straight rigid pipe with a stenosis. Turbulence related artifacts, such as signal drop and ghosting, could be recognized in the measurements as well as in the simulations. The velocity and the IVSD obtained from the magnitude of the phase contrast MRI simulations agreed well with the measurements.

  • 119.
    Petersson, Sven
    et al.
    Linköpings universitet, Institutionen för medicin och hälsa. Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Dyverfeldt, Petter
    Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Sigfridsson, Andreas
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Lantz, Jonas
    Linköpings universitet, Institutionen för teknik och naturvetenskap, Medie- och Informationsteknik. Linköpings universitet, Tekniska högskolan.
    Carlhäll, Carl-Johan
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Quantification of Stenotic Flow Using Spiral 3D Phase-Contrast MRI2013Manuskript (preprint) (Annet vitenskapelig)
    Abstract [en]

    Purpose: To evaluate the feasibility of spiral 3D phase contrast MRI for the assessment of velocity, volume flow rate, peak velocity and turbulent kinetic energy in stenotic flow.

    Materials and Methods: A-stack-of-spirals 3D phase contrast MRI sequence was evaluated in-vitro against a conventional Cartesian sequence. Measurements were made in a flow phantom with a 75% stenosis. Both spiral and Cartesian imaging were performed using different scan orientations and flow rates. Volume flow rate, peak velocity and turbulent kinetic energy (TKE) were computed for both methods. For further validation, the estimated TKE was compared to computational fluid dynamics (CFD) data.

    Results: The volume flow rate, peak velocity and TKE obtained with spiral 4D flow MRI agreed well with Cartesian data and CFD data. As expected, the short echo time of the spiral sequence resulted in less prominent displacement artifacts compared to the Cartesian sequence. However, both spiral and Cartesian flow rate estimates were sensitive to displacement when the flow was oblique to the encoding directions.

    Conclusion: Spiral 3D phase contrast MRI appears favorable for the assessment of stenotic flow. The spiral sequence was more than three times faster and less sensitive to displacement artifacts when compared to a conventional Cartesian sequence.

  • 120.
    Petersson, Sven
    et al.
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin.
    Dyverfeldt, Petter
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Sigfridsson, Andreas
    Karolinska Institute, Sweden; Karolinska University Hospital, Sweden.
    Lantz, Jonas
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten.
    Carlhäll, Carljohan
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Quantification of turbulence and velocity in stenotic flow using spiral three-dimensional phase-contrast MRI2016Inngår i: Magnetic Resonance in Medicine, ISSN 0740-3194, E-ISSN 1522-2594, Vol. 75, nr 3, s. 1249-1255Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    PurposeEvaluate spiral three-dimensional (3D) phase contrast MRI for the assessment of turbulence and velocity in stenotic flow. MethodsA-stack-of-spirals 3D phase contrast MRI sequence was evaluated in vitro against a conventional Cartesian sequence. Measurements were made in a flow phantom with a 75% stenosis. Both spiral and Cartesian imaging were performed using different scan orientations and flow rates. Volume flow rate, maximum velocity and turbulent kinetic energy (TKE) were computed for both methods. Moreover, the estimated TKE was compared with computational fluid dynamics (CFD) data. ResultsThere was good agreement between the turbulent kinetic energy from the spiral, Cartesian and CFD data. Flow rate and maximum velocity from the spiral data agreed well with Cartesian data. As expected, the short echo time of the spiral sequence resulted in less prominent displacement artifacts compared with the Cartesian sequence. However, both spiral and Cartesian flow rate estimates were sensitive to displacement when the flow was oblique to the encoding directions. ConclusionSpiral 3D phase contrast MRI appears favorable for the assessment of stenotic flow. The spiral sequence was more than three times faster and less sensitive to displacement artifacts when compared with a conventional Cartesian sequence.

  • 121.
    Petersson, Sven
    et al.
    Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin.
    Sigfridsson, Andreas
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Medicinska fakulteten.
    Dyverfeldt, Petter
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Carlhäll, Carl-Johan
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Retrospectively Gated Intra-cardiac 4D Flow MRI using Spiral Trajectories2016Inngår i: Magnetic Resonance in Medicine, ISSN 0740-3194, E-ISSN 1522-2594, Vol. 75, nr 1, s. 196-206Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Background: Four-dimensional (4D) flow MRI is a powerful tool for the quantification of blood flow and enables calculation of a range of unique hemodynamic parameters. However, the application of cardiac 4D flow MRI is limited by long scan times (20-40 minutes). The high efficiency of spiral readouts can be used to reduce scan times without sacrificing SNR. The aim of this work was to develop and validate a retrospectively gated 4D flow MRI sequence using spiral readouts for the measurement of intra-cardiac velocities.

    Methods: A retrospectively ECG gated 4D flow sequence using stacks of spiral readouts was implemented on a clinical 1.5 T MRI scanner. The spiral 4D flow MRI sequence was validated in-vivo by comparisons with a two-dimensional (2D) through-plane velocity measurement and a conventional Cartesian 4D flow acquisition (SENSE factor 2) in 7 healthy volunteers (age 27 ± 3 years, four men) and 2 patients (age 19 and 52, women, only spiral 4D flow and 2D). Net volume flow was estimated from all three acquisition approaches and compared using one-way ANOVA. A quantitative pathline based validation was performed on the Cartesian and the spiral 4D flow MRI acquisitions by comparing the left ventricular inflow and outflow (two-tailed paired t-tests).

    Results: The scan time of the spiral 4D flow sequence was 44±6% of the Cartesian counterpart. Compared to time-resolved 2D flow in the aorta, the spiral and Cartesian 4D flow acquisitions provided similarly good data, as there was no significant difference between the net volume flow for all acquisitions (Spiral: 89±14 ml, Cartesian: 93±11 ml, 2D: 93±18 ml, p=0.878). There was no significant difference between pathline-based calculations of inflow and outflow with either Cartesian (In: 88±15, Out: 85±16, p = 0.168) or spiral (In: 93±17 ml, Out: 84±18, p = 0.055) 4D flow acquisitions.

    Conclusions: Retrospectively gated spiral cardiac 4D flow MRI permits more than two-fold reduction in scan time compared to conventional Cartesian 4D flow MRI without notable loss in data quality. The time-savings offered by spiral trajectories could provide a step towards the expanded clinical use of 4D flow MRI.

  • 122.
    Queiros, Sandro
    et al.
    Katholieke University of Leuven, Belgium; ICVS 3Bs PT Govt Associate Lab, Portugal; University of Minho, Portugal.
    Barbosa, Daniel
    ICVS 3Bs PT Govt Associate Lab, Portugal; DIGARC Polytech Institute Cavado and Ave, Portugal.
    Engvall, Jan
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Nagel, Eike
    University Hospital Frankfurt Main, Germany.
    Sarvari, Sebastian I.
    Oslo University Hospital, Norway; Oslo University Hospital, Norway.
    Claus, Piet
    Katholieke University of Leuven, Belgium.
    Fonseca, Jaime C.
    University of Minho, Portugal.
    Vilaca, Joao L.
    ICVS 3Bs PT Govt Associate Lab, Portugal; DIGARC Polytech Institute Cavado and Ave, Portugal.
    Dhooge, Jan
    Katholieke University of Leuven, Belgium.
    Multi-centre validation of an automatic algorithm for fast 4D myocardial segmentation in cine CMR datasets2016Inngår i: European Heart Journal Cardiovascular Imaging, ISSN 2047-2404, E-ISSN 2047-2412, Vol. 17, nr 10, s. 1118-1127Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Aims Quantitative analysis of cine cardiac magnetic resonance (CMR) images for the assessment of global left ventricular morphology and function remains a routine task in clinical cardiology practice. To date, this process requires user interaction and therefore prolongs the examination (i.e. cost) and introduces observer variability. In this study, we sought to validate the feasibility, accuracy, and time efficiency of a novel framework for automatic quantification of left ventricular global function in a clinical setting. Methods and results Analyses of 318 CMR studies, acquired at the enrolment of patients in a multi-centre imaging trial (DOPPLER-CIP), were performed automatically, as well as manually. For comparative purposes, intra-and inter-observer variability was also assessed in a subset of patients. The extracted morphological and functional parameters were compared between both analyses, and time efficiency was evaluated. The automatic analysis was feasible in 95% of the cases (302/318) and showed a good agreement with manually derived reference measurements, with small biases and narrow limits of agreement particularly for end-diastolic volume (-4.08 +/- 8.98 mL), end-systolic volume (1.18 +/- 9.74 mL), and ejection fraction (-1.53 +/- 4.93%). These results were comparable with the agreement between two independent observers. A complete automatic analysis took 5.61 +/- 1.22 s, which is nearly 150 times faster than manual contouring (14 +/- 2 min, P amp;lt; 0.05). Conclusion The proposed automatic framework provides a fast, robust, and accurate quantification of relevant left ventricular clinical indices in real-world cine CMR images.

  • 123.
    Rademakers, Frank
    et al.
    University Hospital Leuven, Belgium .
    Engvall, Jan
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Edvardsen, Thor
    Oslo University Hospital, Norway .
    Monaghan, Mark
    Kings College Hospital London, England .
    Sicari, Rosa
    CNR, Italy .
    Nagel, Eike
    St Thomas Hospital, England .
    Zamorano, Jose
    Hospital University of Ramon and Cajal, Spain .
    Ukkonen, Heikki
    Turku University Hospital, Finland .
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Di Bello, Vitantonio
    University of Pisa, Italy .
    Voigt, Jens-Uwe
    University Hospital Leuven, Belgium .
    Herbots, Lieven
    Katholieke University of Leuven, Belgium .
    Claus, Piet
    University Hospital Leuven, Belgium .
    DHooge, Jan
    Katholieke University of Leuven, Belgium .
    Determining optimal noninvasive parameters for the prediction of left ventricular remodeling in chronic ischemic patients2013Inngår i: Scandinavian Cardiovascular Journal, ISSN 1401-7431, E-ISSN 1651-2006, Vol. 47, nr 6, s. 329-334Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Objectives. DOPPLER-CIP aims to determine the optimal noninvasive parameters (myocardial function, perfusion, ventricular blood flow, cell integrity) and methodology (ergometry, echocardiography, scintigraphy, MRI) in a given ischemic substrate that best predicts the impact of an intervention (or the lack thereof) on adverse morphological ventricular remodeling and functional recovery. Moreover, the relative predictive value of each of these parameters, in respect to the cost of extracting this information in order to enable optimization of cost-effectiveness for improved health care, will be determined by this project. Design. DOPPLER-CIP is a multi-center registry study. All patients with ischemic heart disease included in this study undergo at least two noninvasive stress imaging examinations at baseline. The presence/or absence of left ventricular (LV) remodeling will be assessed after a follow-up of 2 years, during which all cardiac events will be registered. Results. 676 patients were included. Currently, baseline data analysis is almost finished and the follow-up is ongoing. Conclusions. After completion, DOPPLER-CIP will provide evidence-based guidelines toward the most effective use of cardiac imaging in the chronically ischemic heart disease patient. The study will generate information, knowledge, and insight into the new imaging methodologies and into the pathophysiology of chronic ischemic heart disease.

  • 124.
    Renner, Johan
    et al.
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Tekniska högskolan.
    Gårdhagen, Roland
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Tekniska högskolan.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Heiberg, Einar
    Department of Clinical Physiology, Lund University Hospital, Sweden.
    Länne, Toste
    Linköpings universitet, Institutionen för medicin och hälsa, Fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Thorax-kärlkliniken.
    Karlsson, Matts
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Tekniska högskolan.
    A method for subject specific estimation of aortic wall shear stress2009Inngår i: WSEAS Transactions on Biology and Biomedicine, ISSN 1109-9518, Vol. 6, nr 3, s. 49-57Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Wall shear stress (WSS) distribution in the human aorta is a highly interesting hemodynamic factor for atherosclerosis development. We present a magnetic resonance imaging (MRI) and computational fluid dynamics (CFD) based subject specific WSS estimation method and demonstrate it on a group of nine healthy volunteers (males age 23.6 ± 1.3 years). In all nine subjects, the aortic blood flow was simulated in a subject specific way, where the 3D segmented geometries and inflow profiles were obtained using MRI. No parameter settings were tailored using data from the nine subjects. Validation was performed by comparing CFD gained velocity with magnetic resonance imaging (MRI) velocity measurements. CFD and MRI velocity profiles were comparable, but the temporal variations of the differences during the cardiac cycle were significant. Spatio-temporal analyzes on the WSS distribution showed a strong subject specific influence. Subject specific models are decisive to estimate WSS distribution.

  • 125.
    Renner, Johan
    et al.
    Linköpings universitet, Tekniska högskolan. Linköpings universitet, Institutionen för konstruktions- och produktionsteknik, Mekanisk värmeteori och strömningslära.
    Gårdhagen, Roland
    Linköpings universitet, Tekniska högskolan. Linköpings universitet, Institutionen för konstruktions- och produktionsteknik, Mekanisk värmeteori och strömningslära.
    Heiberg, Einar
    Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för medicin och vård, Klinisk fysiologi.
    Ebbers, Tino
    Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för medicin och vård.
    Länne, Toste
    Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för medicin och vård, Fysiologi. Östergötlands Läns Landsting, Hjärtcentrum, Thorax-kärlkliniken.
    Karlsson, Matts
    Linköpings universitet, Tekniska högskolan. Linköpings universitet, Institutionen för medicinsk teknik, Biomedicinsk modellering och simulering.
    Validation of Simulated Velocity of Blood in Patient Specific Aorta2006Inngår i: VIII Svenska Kardiovaskulära Vårmöte,2006, Linköping, Sweden: Linköpings universitet , 2006Konferansepaper (Fagfellevurdert)
  • 126.
    Renner, Johan
    et al.
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Tekniska högskolan.
    Lantz, Jonas
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Tekniska högskolan.
    Ebbers, Tino
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Länne, Toste
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Fysiologi. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Thorax-kärlkliniken i Östergötland.
    Karlsson, Matts
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära. Linköpings universitet, Tekniska högskolan.
    Altered WSS in the human aorta with age – implications for wall remodeling and lesions?2012Konferansepaper (Annet vitenskapelig)
  • 127.
    Rolf, Marijn P
    et al.
    Vrije University Amsterdam Medical Centre.
    Hofman, Mark B M
    Vrije University Amsterdam Medical Centre.
    Gatehouse, Pete rD
    Royal Brompton Hospital.
    Markenroth-Bloch, Karin
    Skane University Hospital.
    Heymans, Martijn W
    Vrije University Amsterdam Medical Centre.
    Ebbers, Tino
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Fysiologi. Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Mekanisk värmeteori och strömningslära.
    Graves, Martin J
    Cambridge University Hospital.
    Totman, John J
    Kings College London.
    Werner, Beat
    University Childrens Hospital.
    van Rossum, Albert C
    Vrije University Amsterdam Medical Centre.
    Kilner, Philip J
    Royal Brompton Hospital.
    Heethaar, Rob M
    Vrije University Amsterdam Medical Centre.
    Sequence optimization to reduce velocity offsets in cardiovascular magnetic resonance volume flow quantification - A multi-vendor study2011Inngår i: JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, ISSN 1097-6647, Vol. 13Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Purpose: Eddy current induced velocity offsets are of concern for accuracy in cardiovascular magnetic resonance (CMR) volume flow quantification. However, currently known theoretical aspects of eddy current behavior have not led to effective guidelines for the optimization of flow quantification sequences. This study is aimed at identifying correlations between protocol parameters and the resulting velocity error in clinical CMR flow measurements in a multi-vendor study. Methods: Nine 1.5T scanners of three different types/vendors were studied. Measurements were performed on a large stationary phantom. Starting from a clinical breath-hold flow protocol, several protocol parameters were varied. Acquisitions were made in three clinically relevant orientations. Additionally, a time delay between the bipolar gradient and read-out, asymmetric versus symmetric velocity encoding, and gradient amplitude and slew rate were studied in adapted sequences as exploratory measurements beyond the protocol. Image analysis determined the worst-case offset for a typical great-vessel flow measurement. Results: The results showed a great variation in offset behavior among scanners (standard deviation among samples of 0.3, 0.4, and 0.9 cm/s for the three different scanner types), even for small changes in the protocol. Considering the absolute values, none of the tested protocol settings consistently reduced the velocity offsets below the critical level of 0.6 cm/s neither for all three orientations nor for all three scanner types. Using multilevel linear model analysis, oblique aortic and pulmonary slices showed systematic higher offsets than the transverse aortic slices (oblique aortic 0.6 cm/s, and pulmonary 1.8 cm/s higher than transverse aortic). The exploratory measurements beyond the protocol yielded some new leads for further sequence development towards reduction of velocity offsets; however those protocols were not always compatible with the time-constraints of breath-hold imaging and flow-related artefacts. Conclusions: This study showed that with current systems there was no generic protocol which resulted into acceptable flow offset values. Protocol optimization would have to be performed on a per scanner and per protocol basis. Proper optimization might make accurate (transverse) aortic flow quantification possible for most scanners. Pulmonary flow quantification would still need further (offline) correction.

  • 128.
    Selskog, Pernilla
    et al.
    Linköpings universitet, Institutionen för medicinsk teknik. Linköpings universitet, Tekniska högskolan.
    Heiberg, Einar
    Linköpings universitet, Institutionen för medicinsk teknik. Linköpings universitet, Institutionen för medicin och vård.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och vård. Linköpings universitet, Hälsouniversitetet.
    Wigström, Lars
    Linköpings universitet, Institutionen för medicinsk teknik. Linköpings universitet, Institutionen för medicin och vård. Linköpings universitet, Hälsouniversitetet.
    Karlsson, Matts
    Linköpings universitet, Institutionen för medicinsk teknik. Linköpings universitet, Tekniska högskolan.
    Kinematics of the heart: strain-rate imaging from time-resolved three-dimensional phase contrast MRI2002Inngår i: IEEE Transactions on Medical Imaging, ISSN 0278-0062, E-ISSN 1558-254X, Vol. 21, nr 9, s. 1105-1109Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    A four-dimensional mapping (three spatial dimensions + time) of myocardial strain-rate would help to describe the mechanical properties of the myocardium, which affect important physiological factors such as the pumping performance of the ventricles. Strain-rate represents the local instantaneous deformation of the myocardium and can be calculated from the spatial gradients of the velocity field. Strain-rate has previously been calculated using one-dimensional (ultrasound) or two-dimensional (2-D) magnetic resonance imaging techniques. However, this assumes that myocardial motion only occurs in one direction or in one plane, respectively. This paper presents a method for calculation of the time-resolved three-dimensional (3-D) strain-rate tensor using velocity vector information in a 3-D spatial grid during the whole cardiac cycle. The strain-rate tensor provides full information of both magnitude and direction of the instantaneous deformation of the myocardium. A method for visualization of the full 3-D tensor is also suggested. The tensors are visualized using ellipsoids, which display the principal directions of strain-rate and the ratio between strain-rate magnitude in each direction. The presented method reveals the principal strain-rate directions without a priori knowledge of myocardial motion directions.

  • 129.
    Selskog, Pernilla
    et al.
    Linköpings universitet, Institutionen för medicinsk teknik, Biomedicinsk modellering och simulering. Linköpings universitet, Tekniska högskolan.
    Torstenfelt, Bo
    Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Hållfasthetslära. Linköpings universitet, Tekniska högskolan.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och vård. Linköpings universitet, Hälsouniversitetet.
    Wigström, Lars
    Linköpings universitet, Institutionen för medicin och vård. Linköpings universitet, Hälsouniversitetet.
    Karlsson, M.
    Linköpings universitet, Institutionen för medicinsk teknik. Linköpings universitet, Tekniska högskolan.
    Kinematics of the Heart: Finite Element and 3D Time-Resolved Phase Contrast Magnetic resonance Imaging2002Inngår i: Proceedings of 9th Workshop on The Finite Element Method in Biomedical Engineering, Biomechanics and Related Fields, 2002Konferansepaper (Fagfellevurdert)
    Abstract [en]

    The complex three-dimensional structure of the heart muscle (myocardium) has anisotropic, non-linear and time-dependent mechanical properties. During the cardiac cycle, the myocardium undergoes large elastic deformations as a consequence of the active muscle contraction along the muscle fibers and their relaxation, respectively. A four-dimensional (4D) description (three spatial dimensions + time) of the mechanical properties of the myocardium would be of interest in the assessment of myocardial function. Time-resolved 3D phase contrast MRI makes it possible to quantify all three velocity components, which is necessary to as accurately as possible describe the velocities in the heart. The velocity data may be used for investigation of the deformation of the heart and calculation of strain in the myocardial wall. We present a method for estimation of myocardial kinematics using finite elements and 3D time-resolved phase contrast MRI.

  • 130.
    Sengupta, Partho P
    et al.
    Mt Sinai School of Medicine.
    Pedrizzetti, Gianni
    University of Trieste.
    Kilner, Philip J
    Royal Brompton Hospital.
    Kheradvar, Arash
    University of Calif Irvine.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för teknik och naturvetenskap, Medie- och Informationsteknik.
    Tonti, Giovanni
    SS Annunziata Hospital.
    Fraser, Alan G
    Cardiff University.
    Narula, Jagat
    Mt Sinai School of Medicine.
    Emerging Trends in CV Flow Visualization2012Inngår i: JACC Cardiovascular Imaging, ISSN 1936-878X, E-ISSN 1876-7591, Vol. 5, nr 3, s. 305-316Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Blood flow patterns are closely linked to the morphology and function of the cardiovascular system. These patterns reflect the exceptional adaptability of the cardiovascular system to maintain normal blood circulation under a wide range of workloads. Accurate retrieval and display of flow-related information remains a challenge because of the processes involved in mapping the flow velocity fields within specific chambers of the heart. We review the potentials and pitfalls of current approaches for blood flow visualization, with an emphasis on acquisition, display, and analysis of multidirectional flow. This document is divided into 3 sections. First, we provide a descriptive outline of the relevant concepts in cardiac fluid mechanics, including the emergence of rotation in flow and the variables that delineate vortical structures. Second, we elaborate on the main methods developed to image and visualize multidirectional cardiovascular flow, which are mainly based on cardiac magnetic resonance, ultrasound Doppler, and contrast particle imaging velocimetry, with recommendations for developing dedicated imaging protocols. Finally, we discuss the potential clinical applications and technical challenges with suggestions for further investigations.

  • 131.
    Sigfridsson, Andreas
    et al.
    Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Heiberg, Einar
    Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Wigström, Lars
    Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Tensor Field Visualisation using Adaptive Filtering of Noise Fields combined with Glyph Rendering2002Inngår i: IEEE Visualization 2002 Conference, IEEE , 2002, s. 371-378Konferansepaper (Fagfellevurdert)
    Abstract [en]

    While many methods exist for visualising scalar and vector data, visualisation of tensor data is still troublesome. We present a method for visualising second order tensors in three dimensions using a hybrid between direct volume rendering and glyph rendering.

    An overview scalar field is created by using three-dimensional adaptive filtering of a scalar field containing noise. The filtering process is controlled by the tensor field to be visualised, creating patterns that characterise the tensor field. By combining direct volume rendering of the scalar field with standard glyph rendering methods for detailed tensor visualisation, a hybrid solution is created.

    A combined volume and glyph renderer was implemented and tested with both synthetic tensors and strain-rate tensors from the human heart muscle, calculated from phase contrast magnetic resonance image data. A comprehensible result could be obtained, giving both an overview of the tensor field as well as detailed information on individual tensors.

  • 132.
    Sigfridsson, Andreas
    et al.
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Haraldsson, Henrik
    Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Knutsson, Hans
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicinsk teknik, Medicinsk informatik. Linköpings universitet, Tekniska högskolan.
    Sakuma, Hajima
    Mie University, Japan.
    SNR evaluation of 32 channel cardiac coils in DENSE MRI at 1.5 and 3T2010Inngår i: ISMRM 2010, International Society for Magnetic Resonance in Medicine ( ISMRM ) , 2010Konferansepaper (Annet vitenskapelig)
  • 133.
    Sigfridsson, Andreas
    et al.
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Haraldsson, Henrik
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Ebbers, Tino
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Knutsson, Hans
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicinsk teknik, Medicinsk informatik. Linköpings universitet, Tekniska högskolan.
    Sakuma, Hajime
    Mie University, Tsu, Mie, Japan.
    In­vivo SNR in DENSE MRI: temporal and regional effects of field  strength, receiver coil sensitivity, and flip angle strategies2009Inngår i: Proceedings of the ISMRM Workshop on Cardiovascular Flow,  Function & Tissue Mechanics, 2009Konferansepaper (Annet vitenskapelig)
  • 134.
    Sigfridsson, Andreas
    et al.
    Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Haraldsson, Henrik
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet.
    Ebbers, Tino
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Fysiologi. Linköpings universitet, Hälsouniversitetet.
    Knutsson, Hans
    Linköpings universitet, Institutionen för medicinsk teknik, Medicinsk informatik. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Hälsouniversitetet.
    Sakuma, Hajime
    Radiology, Mie University, Japan.
    In-vivo SNR in DENSE MRI: temporal and regional effects of field strength, receiver coil sensitivity, and flip angle strategies2011Inngår i: Magnetic Resonance Imaging, ISSN 0730-725X, E-ISSN 1873-5894, Vol. 29, nr 2, s. 202-208Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Aim: The influences on the SNR of DENSE MRI of field strength, receiver coil sensitivity and choice of flip angle strategy have been previously investigated individually. In this study, all of these parameters have been investigated in the same setting, and a mutual comparison of their impact on SNR is presented.

    Materials and methods: Ten healthy volunteers were imaged in a 1.5T and a 3T MRI system, using standard 5 or 6 channel cardiac coils as well as 32 channel coils, with four different excitation patterns. Variation of spatial coil sensitivity was assessed by regional SNR analysis.

    Results: SNR ranging from 2.8 to 30.5 was found depending on the combination of excitation patterns, coil sensitivity and field strength. The SNR at 3T was 53 ± 26% higher than at 1.5T (p<0.001), whereas spatial differences of 59 ± 26% were found in the ventricle (p<0.001). 32 channel coils provided 52 ± 29% higher SNR compared to standard 5 or 6 channel coils (p<0.001). A fixed flip angle strategy provided an excess of 50% higher SNR in half of the imaged cardiac cycle compared to a sweeping flip angle strategy, and a single phase acquisition provided a six-fold increase of SNR compared to a cine acquisition.

    Conclusion: The effect of field strength and receiver coil sensitivity influences the SNR with the same order of magnitude, whereas flip angle strategy can have a larger effect on SNR. Thus, careful choice of imaging hardware in combination with adaptation of the acquisition protocol is crucial in order to realize sufficient SNR in DENSE MRI.

  • 135.
    Sigfridsson, Andreas
    et al.
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Haraldsson, Henrik
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Ebbers, Tino
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Knutsson, Hans
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicinsk teknik, Medicinsk informatik. Linköpings universitet, Tekniska högskolan.
    Sakuma, Hajime
    Radiology, Mie University, Japan.
    Single Breath Hold Multiple Slice DENSE MRI2010Inngår i: Magnetic Resonance in Medicine, ISSN 0740-3194, E-ISSN 1522-2594, Vol. 63, nr 5, s. 1411-1414Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    A method to acquire multiple displacement encoded slices within asingle breath hold is presented. Efficiency is improved overconventional Displacement ENcoding with Stimulated Echoes (DENSE) without compromising image quality by read-out of multiple slices inthe same cardiac cycle, thus utilizing the position encoded stimulatedecho available in the whole heart. The method was evaluated bycomparing strain values obtained using the proposed method to strainvalues obtained by conventional separate breath hold single-sliceDENSE acquisitions. Good agreement (Lagrangian E2 strainbias=0.000, 95% limits of agreement ±0.04,root-mean-square-difference 0.02 (9.4% of the mean end-systolic E2)) was found between the methods, indicating that the proposedmethod can replace a multiple breath hold acquisition. Eliminating theneed for multiple breath holds reduces the risk of changes in breathhold positions or heart rate, results in higher patient comfort andfacilitates inclusion of DENSE in a clinical routine protocol.

  • 136.
    Sigfridsson, Andreas
    et al.
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicinsk teknik, Medicinsk informatik. Linköpings universitet, Tekniska högskolan.
    Haraldsson, Henrik
    Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Takase, S.
    Mie University, Tsu, Mie, Japan.
    Knutsson, Hans
    Linköpings universitet, Institutionen för medicinsk teknik, Medicinsk informatik. Linköpings universitet, Tekniska högskolan.
    Sakuma, H.
    Mie University, Tsu, Mie, Japan.
    Flip Angle Strategies for Multiphase DENSE2009Konferansepaper (Fagfellevurdert)
    Abstract [en]

    In multiphase DENSE MRI, available signal decreases during the cardiac cycle due to excitation and T1-relaxation. Because of this, a widely used method is to vary the flip angle to yield constant SNR during the cardiac cycle. Unfortunately, this may lead to significant sacrifices of SNR in the early cardiac phases.

  • 137.
    Sigfridsson, Andreas
    et al.
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicinsk teknik, Medicinsk informatik. Linköpings universitet, Tekniska högskolan.
    Haraldsson, Henrik
    Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Takase, S.
    Mie University, Tsu, Mie, Japan.
    Sakuma, H.
    Mie University, Tsu, Mie, Japan.
    Multi Slice DENSE in a Single Breath Hold2009Konferansepaper (Fagfellevurdert)
  • 138.
    Sigfridsson, Andreas
    et al.
    Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Petersson, Sven
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Hälsouniversitetet.
    Carlhäll, Carljohan
    Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Four-dimensional flow MRI using spiral acquisition2012Inngår i: Magnetic Resonance in Medicine, ISSN 0740-3194, E-ISSN 1522-2594, Vol. 68, nr 4, s. 1065-1073Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Time-resolved three-dimensional phase-contrast MRI is an important tool for physiological as well as clinical studies of blood flow in the heart and vessels. The application of the technique is, however, limited by the long scan times required. In this work, we investigate the feasibility of using spiral readouts to reduce the scan time of four-dimensional flow MRI without sacrificing quality. Three spiral approaches are presented and evaluated in vivo and in vitro against a conventional Cartesian acquisition. In vivo, the performance of each method was assessed in the thoracic aorta in 10 volunteers using pathline-based analysis and cardiac output analysis. Signal-to-noise ratio and background phase errors were investigated in vitro. Using spiral readouts, the scan times of a four-dimensional flow acquisition of the thoracic aorta could be reduced 23-fold, with no statistically significant difference in pathline validity or cardiac output. The shortened scan time improves the applicability of four-dimensional flow MRI, which may allow the technique to become a part of a clinical workflow for cardiovascular functional imaging.

  • 139.
    Stoll, Victoria M.
    et al.
    Univ Oxford, England.
    Hess, Aaron T.
    Univ Oxford, England.
    Rodgers, Christopher T.
    Univ Oxford, England; Univ Cambridge, England.
    Bissell, Malenka M.
    Univ Oxford, England.
    Dyverfeldt, Petter
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Primärvårdscentrum, Vårdcentralen Ödeshög. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Myerson, Saul G.
    Univ Oxford, England.
    Carlhäll, Carljohan
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Neubauer, Stefan
    Univ Oxford, England.
    Left Ventricular Flow Analysis Novel Imaging Biomarkers and Predictors of Exercise Capacity in Heart Failure2019Inngår i: Circulation Cardiovascular Imaging, ISSN 1941-9651, E-ISSN 1942-0080, Vol. 12, nr 5Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Background: Cardiac remodeling, after a myocardial insult, often causes progression to heart failure. The relationship between alterations in left ventricular blood flow, including kinetic energy (KE), and remodeling is uncertain. We hypothesized that increasing derangements in left ventricular blood flow would relate to (1) conventional cardiac remodeling markers, (2) increased levels of biochemical remodeling markers, (3) altered cardiac energetics, and (4) worsening patient symptoms and functional capacity. Methods: Thirty-four dilated cardiomyopathy patients, 30 ischemic cardiomyopathy patients, and 36 controls underwent magnetic resonance including 4-dimensional flow, BNP (brain-type natriuretic peptide) measurement, functional capacity assessment (6-minute walk test), and symptom quantification. A subgroup of dilated cardiomyopathy and control subjects underwent cardiac energetic assessment. Left ventricular flow was separated into 4 components: direct flow, retained inflow, delayed ejection flow, and residual volume. Average KE throughout the cardiac cycle was calculated. Results: Patients had reduced direct flow proportion and direct-flow average KE compared with controls (Pamp;lt;0.0001). The residual volume proportion and residual volume average KE were increased in patients (Pamp;lt;0.0001). Importantly, in a multiple linear regression model to predict the patients 6-minute walk test, the independent predictors were age (beta=-0.3015; P=0.019) and direct-flow average KE (beta=0.280, P=0.035; R-2 model, 0.466, P=0.002). In contrast, neither ejection fraction nor left ventricular volumes were independently predictive. Conclusions: This study demonstrates an independent predictive relationship between the direct-flow average KE and a prognostic measure of functional capacity. Intracardiac 4-dimensional flow parameters are novel biomarkers in heart failure and may provide additive value in monitoring new therapies and predicting prognosis.

  • 140.
    Stoll, Victoria M.
    et al.
    Univ Oxford, England.
    Loudon, Margaret
    Univ Oxford, England.
    Eriksson, Jonatan
    Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin.
    Bissell, Malenka M.
    Univ Oxford, England.
    Dyverfeldt, Petter
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Myerson, Saul G.
    Univ Oxford, England.
    Neubauer, Stefan
    Univ Oxford, England.
    Carlhäll, Carljohan
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Hess, Aaron T.
    Univ Oxford, England.
    Test-retest variability of left ventricular 4D flow cardiovascular magnetic resonance measurements in healthy subjects2018Inngår i: Journal of Cardiovascular Magnetic Resonance, ISSN 1097-6647, E-ISSN 1532-429X, Vol. 20, artikkel-id 15Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Background: Quantification and visualisation of left ventricular (LV) blood flow is afforded by three-dimensional, time resolved phase contrast cardiovascular magnetic resonance (CMR 4D flow). However, few data exist upon the repeatability and variability of these parameters in a healthy population. We aimed to assess the repeatability and variability over time of LV 4D CMR flow measurements. Methods: Forty five controls underwent CMR 4D flow data acquisition. Of these, 10 underwent a second scan within the same visit (scan-rescan), 25 returned for a second visit (interval scan; median interval 52 days, IQR 28-57 days). The LV-end diastolic volume (EDV) was divided into four flow components: 1) Direct flow: inflow that passes directly to ejection; 2) Retained inflow: inflow that enters and resides within the LV; 3) Delayed ejection flow: starts within the LV and is ejected and 4) Residual volume: blood that resides within the LV for amp;gt;2 cardiac cycles. Each flow components volume was related to the EDV (volume-ratio). The kinetic energy at end-diastole (ED) was measured and divided by the components volume. Results: The dominant flow component in all 45 controls was the direct flow (volume ratio 38 +/- 4%) followed by the residual volume (30 +/- 4%), then delayed ejection flow (16 +/- 3%) and retained inflow (16 +/- 4%). The kinetic energy at ED for each component was direct flow (7.8 +/- 3.0 microJ/ml), retained inflow (4.1 +/- 2.0 microJ/ml), delayed ejection flow (6. 3 +/- 2.3 microJ/ml) and the residual volume (1.2 +/- 0.5 microJ/ml). The coefficients of variation for the scan-rescan ranged from 2.5%-9.2% for the flow components volume ratio and between 13.5%-17.7% for the kinetic energy. The interval scan results showed higher coefficients of variation with values from 6.2-16.1% for the flow components volume ratio and 16.9-29.0% for the kinetic energy of the flow components. Conclusion: LV flow components volume and their associated kinetic energy values are repeatable and stable within a population over time. However, the variability of these measurements in individuals over time is greater than can be attributed to sources of error in the data acquisition and analysis, suggesting that additional physiological factors may influence LV flow measurements.

  • 141.
    Svalbring, Emil
    et al.
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten.
    Fredriksson, Alexandru
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten.
    Eriksson, Jonatan
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten.
    Dyverfeldt, Petter
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Bolger, Ann F
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Department of Medicine, University of California San Francisco, San Francisco, California, United States of America.
    Engvall, Jan
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Carlhäll, Carljohan
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Altered Diastolic Flow Patterns and Kinetic Energy in Subtle Left Ventricular Remodeling and Dysfunction Detected by 4D Flow MRI2016Inngår i: PLoS ONE, ISSN 1932-6203, E-ISSN 1932-6203, Vol. 11, nr 8, s. 1-12, artikkel-id e0161391Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Aims: 4D flow magnetic resonance imaging (MRI) allows quantitative assessment of left ventricular (LV) function according to characteristics of the dynamic flow in the chamber. Marked abnormalities in flow components volume and kinetic energy (KE) have previously been demonstrated in moderately dilated and depressed LVs compared to healthy subjects. We hypothesized that these 4D flow-based measures would detect even subtle LV dysfunction and remodeling.

    Methods and Results: We acquired 4D flow and morphological MRI data from 26 patients with chronic ischemic heart disease with New York Heart Association (NYHA) class I and II and with no to mild LV systolic dysfunction and remodeling, and from 10 healthy controls. A previously validated method was used to separate the LV end-diastolic volume (LVEDV) into functional components: direct flow, which passes directly to ejection, and non-ejecting flow, which remains in the LV for at least 1 cycle. The direct flow and non-ejecting flow proportions of end-diastolic volume and KE were assessed. The proportions of direct flow volume and KE fell with increasing LVEDV-index (LVEDVI) and LVESV-index (LVESVI) (direct flow volume r = -0.64 and r = -0.74, both Pamp;lt;0.001; direct flow KE r = -0.48, P = 0.013, and r = -0.56, P = 0.003). The proportions of non-ejecting flow volume and KE rose with increasing LVEDVI and LVESVI (non-ejecting flow volume: r = 0.67 and r = 0.76, both Pamp;lt;0.001; non-ejecting flow KE: r = 0.53, P = 0.005 and r = 0.52, P = 0.006). The proportion of direct flow volume correlated moderately to LVEF (r = 0.68, P amp;lt; 0.001) and was higher in a sub-group of patients with LVEDVI amp;gt; 74 ml/m(2) compared to patients with LVEDVI amp;lt; 74 ml/m(2) and controls (both Pamp;lt;0.05).

    Conclusion: Direct flow volume and KE proportions diminish with increased LV volumes, while non-ejecting flow proportions increase. A decrease in direct flow volume and KE at end-diastole proposes that alterations in these novel 4D flow-specific markers may detect LV dysfunction even in subtle or subclinical LV remodeling.

  • 142.
    Svensson (Renner), Johan
    et al.
    Linköpings universitet, Institutionen för konstruktions- och produktionsteknik, Mekanisk värmeteori och strömningslära. Linköpings universitet, Tekniska högskolan. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Gårdhagen, Roland
    Linköpings universitet, Institutionen för konstruktions- och produktionsteknik, Mekanisk värmeteori och strömningslära. Linköpings universitet, Tekniska högskolan. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Heiberg, Einar
    Department of Clinical Physiology, Lund University, Sweden.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och vård. Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Loyd, Dan
    Linköpings universitet, Institutionen för konstruktions- och produktionsteknik, Mekanisk värmeteori och strömningslära. Linköpings universitet, Tekniska högskolan.
    Länne, Toste
    Linköpings universitet, Institutionen för medicin och vård, Fysiologi. Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Östergötlands Läns Landsting, Hjärtcentrum, Thorax-kärlkliniken.
    Karlsson, Matts
    Linköpings universitet, Institutionen för medicinsk teknik, Biomedicinsk modellering och simulering. Linköpings universitet, Tekniska högskolan. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Feasibility of Patient Specific Aortic Blood Flow CFD Simulation2006Inngår i: Medical Image Computing and Computer-Assisted Intervention – MICCAI 2006: 9th International Conference, Copenhagen, Denmark, October 1-6, 2006. Proceedings, Part I / [ed] Rasmus Larsen, Mads Nielsen and Jon Sporring, Springer Berlin/Heidelberg, 2006, 1, Vol. 4190, s. 257-263Konferansepaper (Fagfellevurdert)
    Abstract [en]

    Patient specific modelling of the blood flow through the human aorta is performed using computational fluid dynamics (CFD) and magnetic resonance imaging (MRI). Velocity patterns are compared between computer simulations and measurements. The workflow includes several steps: MRI measurement to obtain both geometry and velocity, an automatic levelset segmentation followed by meshing of the geometrical model and CFD setup to perform the simulations follwed by the actual simulations. The computational results agree well with the measured data.

  • 143.
    Thunberg, Per
    et al.
    Linköpings universitet, Institutionen för medicinsk teknik. Linköpings universitet, Institutionen för medicin och vård, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet.
    Wigström, Lars
    Linköpings universitet, Institutionen för medicinsk teknik. Linköpings universitet, Institutionen för medicin och vård, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och vård, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet.
    Karlsson, Matts
    Linköpings universitet, Institutionen för medicinsk teknik. Linköpings universitet, Tekniska högskolan.
    Correction for displacement artifacts in 3D phase contrast imaging2002Inngår i: Journal of Magnetic Resonance Imaging, ISSN 1053-1807, E-ISSN 1522-2586, Vol. 16, nr 5, s. 591-597Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Purpose

    To correct for displacement artifacts in 3D phase contrast imaging.

    Materials and Methods

    A 3D phase contrast pulse sequence was modified so that displacements of velocity measurements were restricted to one direction. By applying a postprocessing method, displaced measurements could be traced back to their accurate positions. Flow studies were performed using a phantom that generated flow through a stenosis, directed oblique relative to the phase and frequency encoding directions. Velocity profiles and streamline visualization were used to compare displaced and corrected velocity data to a reference.

    Results

    Velocity profiles obtained from the original measurement showed skewed profiles due to the displacement artifact, both at close proximity to the orifice as well as further downstream. After correction, concordance with the reference improved considerably.

    Conclusion

    The displacement artifact, which restricts the accuracy of phase contrast measurements, can be corrected for using the proposed method. Correction of the phase contrast velocity data may improve the accuracy of subsequent flow analysis and visualization.

  • 144.
    Viola, Frederica
    et al.
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten.
    Dyverfeldt, Petter
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Carlhäll, Carljohan
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Primärvårdscentrum, Vårdcentralen Ödeshög. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Data Quality and Optimal Background Correction Order of Respiratory-Gated k-Space Segmented Spoiled Gradient Echo (SGRE) and Echo Planar Imaging (EPI)-Based 4D Flow MRI2019Inngår i: Journal of Magnetic Resonance Imaging, ISSN 1053-1807, E-ISSN 1522-2586Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Background A reduction in scan time of 4D Flow MRI would facilitate clinical application. A recent study indicates that echo-planar imaging (EPI) 4D Flow MRI allows for a reduction in scan time and better data quality than the recommended k-space segmented spoiled gradient echo (SGRE) sequence. It was argued that the poor data quality of SGRE was related to the nonrecommended absence of respiratory motion compensation. However, data quality can also be affected by the background offset compensation. Purpose To compare the data quality of respiratory motion-compensated SGRE and EPI 4D Flow MRI and their dependence on background correction (BC) order. Study Type Retrospective. Subjects Eighteen healthy subjects (eight female, mean age 32 +/- 5 years). Field Strength and Sequence 5T. SGRE and EPI-based 4D Flow MRI. Assessment Data quality was investigated visually and by comparing flows through the cardiac valves and aorta. Measurements were obtained from transvalvular flow and pathline analysis. Statistical Tests Linear regression and Bland-Altman analysis were used. Wilcoxon test was used for comparison of visual scoring. Students t-test was used for comparison of flow volumes. Results No significant difference was found by visual inspection (P = 0.08). Left ventricular (LV) flows were strongly and very strongly associated with SGRE and EPI, respectively (R-2 = 0.86-0.94 SGRE; 0.71-0.79 EPI, BC0-4). LV and right ventricular (RV) outflows and LV pathline flows were very strongly associated (R-2 = 0.93-0.95 SGRE; 0.88-0.91 EPI, R-2 = 0.91-0.95 SGRE; 0.91-0.93 EPI, BC1-4). EPI LV outflow was lower than the short-axis-based stroke volume. EPI RV outflow and proximal descending aortic flow were lower than SGREs. Data Conclusion Both sequences yielded good internal data consistency when an adequate background correction was applied. Second and first BC order were considered sufficient for transvalvular flow analysis in SGRE and EPI, respectively. Higher BC orders were preferred for particle tracing. Technical Efficacy Stage 1 J. Magn. Reson. Imaging 2019.

  • 145.
    Wigström, Lars
    et al.
    Linköpings universitet, Institutionen för medicin och vård, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicinsk teknik. Linköpings universitet, Tekniska högskolan.
    Fyrenius, Anna
    Linköpings universitet, Institutionen för medicin och vård, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet.
    Karlsson, Matts
    Linköpings universitet, Institutionen för medicinsk teknik. Linköpings universitet, Institutionen för konstruktions- och produktionsteknik. Linköpings universitet, Tekniska högskolan.
    Engvall, Jan
    Linköpings universitet, Institutionen för medicin och vård, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet.
    Wranne, Bengt
    Linköpings universitet, Institutionen för medicin och vård, Klinisk fysiologi. Linköpings universitet, Hälsouniversitetet.
    Bolger, Ann F.
    Division of Biomedical Science, University of California at Riverside, Riverside, California.
    Particle trace visualization of intracardiac flow using time-resolved 3D phase contrast MRI1999Inngår i: Magnetic Resonance in Medicine, ISSN 0740-3194, E-ISSN 1522-2594, Vol. 41, nr 4, s. 793-799Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    The flow patterns in the human heart are complex and difficult to visualize using conventional two-dimensional (2D) modalities, whether they depict a single velocity component (Doppler echocardiography) or all three components in a few slices (2D phase contrast MRI). To avoid these shortcomings, a temporally resolved 3D phase contrast technique was used to derive data describing the intracardiac velocity fields in normal volunteers. The MRI data were corrected for phase shifts caused by eddy currents and concomitant gradient fields, with improvement in the accuracy of subsequent flow visualizations. Pathlines describing the blood pathways through the heart were generated from the temporally resolved velocity data, starting from user-specified locations and time frames. Flow trajectories were displayed as 3D particle traces, with simultaneous demonstration of morphologic 2D slices. This type of visualization is intuitive and interactive and may extend our understanding of dynamic and previously unrecognized patterns of intracardiac flow.

  • 146.
    Wigström, Lars
    et al.
    Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för medicin och vård, Klinisk fysiologi. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Ebbers, Tino
    Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för medicin och vård, Klinisk fysiologi. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Fyrenius, Anna
    Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för medicin och vård, Klinisk fysiologi.
    Karlsson, Matts
    Linköpings universitet, Tekniska högskolan. Linköpings universitet, Institutionen för medicinsk teknik, Biomedicinsk modellering och simulering.
    Engvall, Jan
    Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för medicin och vård, Klinisk fysiologi. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Wranne, Bengt
    Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för medicin och vård, Klinisk fysiologi. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Bolger, Ann F
    Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för medicin och vård, Klinisk fysiologi. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    The effects of maxwell terms on particle traces calculated from 3D cine phase contrast images1999Inngår i: Journal of Cardiovascular Magnetic Resonance,1999, 1999, s. 93-93Konferansepaper (Annet vitenskapelig)
  • 147.
    Yoon, EJ
    et al.
    Univ Calif San Francisco, San Francisco, CA 94143 USA Linkoping Univ, Linkoping, Sweden.
    Engvall, J
    Ebbers, Tino
    Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Brandt, E
    Univ Calif San Francisco, San Francisco, CA 94143 USA Linkoping Univ, Linkoping, Sweden.
    Wigström, Lars
    Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Wranne, Bengt
    Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för medicin och hälsa, Klinisk fysiologi. Östergötlands Läns Landsting, Hjärtcentrum, Fysiologiska kliniken.
    Bolger, A
    Reversal of blood flow in the descending aorta: Implications for Doppler quantitation of aortic insufficiency2002Inngår i: Journal of the American College of Cardiology, ISSN 0735-1097, E-ISSN 1558-3597, Vol. 39, nr 5, s. 425A-425AKonferansepaper (Annet vitenskapelig)
  • 148.
    Zajac, Jacub
    et al.
    Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Eriksson, Jonatan
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Hälsouniversitetet.
    Dyverfeldt, Petter
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Bolger, Ann F.
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Department of Medicine, University of California San Francisco, San Francisco, CA, USA.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för teknik och naturvetenskap, Medie- och Informationsteknik. Linköpings universitet, Tekniska högskolan. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Carlhäll, Carl-Johan
    Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Turbulent Kinetic Energy in Normal and Myopathic Left Ventricles2015Inngår i: Journal of Magnetic Resonance Imaging, ISSN 1053-1807, E-ISSN 1522-2586, Vol. 41, nr 4, s. 1021-1029Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Purpose: To assess turbulent kinetic energy (TKE) within the left ventricle (LV) of healthy subjects using novel 4D flow MRI methods and to compare TKE values to those from a spectrum of patients with dilated cardiomyopathy (DCM).

    Methods: 4D flow and morphological MRI-data were acquired in 11 healthy subjects and 9 patients with different degrees of diastolic dysfunction. TKELV was calculated within the LV at each diastolic time frame. At peak early (E) and late (A) diastolic filling, the TKELV was compared to transmitral peak velocity, LV diameter and mitral annular diameter.

    Results: In the majority of all subjects, peaks in TKELV could be observed at E and A. Peak TKELV at E was not different between the groups, and correlated with mitral annular dimensions. Peak TKELV at A was higher in DCM patients compared to healthy subjects, and was related to LV diameter and transmitral velocity.

    Conclusions: In normal LVs, TKE values are low. Values are highest during early diastole, and diminish with increasing LV size. In a heterogeneous group of DCM patients, late diastolic TKE values are higher than in healthy subjects. Kinetic energy loss due to elevated late diastolic TKE may reflect inefficient flow in dilated LVs.

  • 149.
    Zajac, Jakub
    et al.
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Eriksson, Jonatan
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Alehagen, Urban
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Kardiologiska kliniken US.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Bolger, Ann F
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Department of Medicine, University of California San Francisco, CA, USA.
    Carlhäll, Carljohan
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US.
    Mechanical dyssynchrony alters left ventricular flow energetics in failing hearts with LBBB: a 4D flow CMR pilot study.2018Inngår i: The International Journal of Cardiovascular Imaging, ISSN 1569-5794, E-ISSN 1875-8312, Vol. 34, nr 4, s. 587-596Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    The impact of left bundle branch block (LBBB) related mechanical dyssynchrony on left ventricular (LV) diastolic function remains unclear. 4D flow cardiovascular magnetic resonance (CMR) has provided reliable markers of LV dysfunction: reduced volume and kinetic energy (KE) of the portion of LV inflow which passes directly to outflow (Direct Flow) has been demonstrated in failing hearts compared to normal hearts. We sought to investigate the impact of mechanical dyssynchrony on diastolic function by comparing 4D flow in myopathic LVs with and without LBBB. CMR data were acquired at 3 T in 22 heart failure patients; 11 with LBBB and 11 without LBBB matched according to several demographic and clinical parameters. An established 4D flow analysis method was used to separate the LV end-diastolic (ED) volume into functional flow components based on the blood's timing and route through the heart cavities. While the Direct Flow volume was not different between the groups, the KE possessed at ED was lower in LBBB patients (P = 0.018). Direct Flow entering the LV during early diastolic filling possessed less KE at ED in LBBB patients compared to non-LBBB patients, whereas no intergroup difference was observed during late filling. Pre-systolic KE of LV Direct Flow was reduced in patients with LBBB compared to matched patients with normal conduction. These intriguing findings propose that 4D flow specific measures can serve as markers of LV mechanical dyssynchrony in heart failure patients, and could possibly be investigated as predictors of response to cardiac resynchronization therapy.

  • 150.
    Zhong, Liang
    et al.
    Natl Heart Ctr Singapore, Singapore; Natl Univ Singapore, Singapore.
    Schrauben, Eric M.
    Hosp Sick Children, Canada.
    Garcia, Julio
    Univ Calgary, Canada.
    Uribe, Sergio
    Pontificia Univ Catolica Chile, Chile.
    Grieve, Stuart M.
    Univ Sydney, Australia; Royal Prince Alfred Hosp, Australia.
    Elbaz, Mohammed S. M.
    Northwestern Univ, IL 60611 USA.
    Barker, Alex J.
    Univ Colorado, CO 80202 USA.
    Geiger, Julia
    Univ Childrens Hosp Zurich, Switzerland.
    Nordmeyer, Sarah
    German Heart Ctr, Germany; Charite, Germany.
    Marsden, Alison
    Stanford Univ, CA 94305 USA.
    Carlsson, Marcus
    Lund Univ, Sweden.
    Tan, Ru-San
    Natl Heart Ctr Singapore, Singapore; Natl Univ Singapore, Singapore.
    Garg, Pankaj
    Univ Sheffield, England.
    Westenberg, Jos J. M.
    Leiden Univ, Netherlands.
    Markl, Michael
    Northwestern Univ, IL 60611 USA.
    Ebbers, Tino
    Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Primärvårdscentrum, Vårdcentralen Ödeshög. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
    Intracardiac 4D Flow MRI in Congenital Heart Disease: Recommendations on Behalf of the ISMRM Flow & Motion Study Group2019Inngår i: Journal of Magnetic Resonance Imaging, ISSN 1053-1807, E-ISSN 1522-2586Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2019.

1234 101 - 150 of 152
RefereraExporteraLink til resultatlisten
Permanent link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf