liu.seSearch for publications in DiVA
Change search
Refine search result
1 - 5 of 5
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Rows per page
  • 5
  • 10
  • 20
  • 50
  • 100
  • 250
Sort
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
  • Disputation date (earliest first)
  • Disputation date (latest first)
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
  • Disputation date (earliest first)
  • Disputation date (latest first)
Select
The maximal number of hits you can export is 250. When you want to export more records please use the Create feeds function.
  • 1.
    Gu, Xuan
    et al.
    Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Faculty of Science & Engineering.
    Knutsson, Hans
    Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Faculty of Science & Engineering. Linköping University, Center for Medical Image Science and Visualization (CMIV).
    Nilsson, Markus
    Department of Clinical Sciences, Radiology, Lund UniversityLundSweden.
    Eklund, Anders
    Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Department of Computer and Information Science, The Division of Statistics and Machine Learning. Linköping University, Faculty of Science & Engineering. Linköping University, Center for Medical Image Science and Visualization (CMIV).
    Generating Diffusion MRI Scalar Maps from T1 Weighted Images Using Generative Adversarial Networks2019In: Image Analysis: Lecture Notes in Computer Science / [ed] Felsberg M., Forssén PE., Sintorn IM., Unger J., Springer Publishing Company, 2019, p. 489-498Conference paper (Refereed)
    Abstract [en]

    Diffusion magnetic resonance imaging (diffusion MRI) is a non-invasive microstructure assessment technique. Scalar measures, such as FA (fractional anisotropy) and MD (mean diffusivity), quantifying micro-structural tissue properties can be obtained using diffusion models and data processing pipelines. However, it is costly and time consuming to collect high quality diffusion data. Here, we therefore demonstrate how Generative Adversarial Networks (GANs) can be used to generate synthetic diffusion scalar measures from structural T1-weighted images in a single optimized step. Specifically, we train the popular CycleGAN model to learn to map a T1 image to FA or MD, and vice versa. As an application, we show that synthetic FA images can be used as a target for non-linear registration, to correct for geometric distortions common in diffusion MRI.

  • 2.
    Gu, Xuan
    et al.
    Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Faculty of Science & Engineering. Linköping University, Center for Medical Image Science and Visualization (CMIV).
    Eklund, Anders
    Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Department of Computer and Information Science, The Division of Statistics and Machine Learning. Linköping University, Faculty of Science & Engineering. Linköping University, Center for Medical Image Science and Visualization (CMIV).
    Özarslan, Evren
    Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Faculty of Science & Engineering. Linköping University, Center for Medical Image Science and Visualization (CMIV).
    Knutsson, Hans
    Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Faculty of Science & Engineering. Linköping University, Center for Medical Image Science and Visualization (CMIV).
    Using the wild bootstrap to quantify uncertainty in mean apparent propagator MRI2019In: Frontiers in Neuroinformatics, ISSN 1662-5196, E-ISSN 1662-5196, Vol. 13, article id 43Article in journal (Refereed)
    Abstract [en]

    Purpose: Estimation of uncertainty of MAP-MRI metricsis an important topic, for several reasons. Bootstrap deriveduncertainty, such as the standard deviation, providesvaluable information, and can be incorporated in MAP-MRIstudies to provide more extensive insight.

    Methods: In this paper, the uncertainty of different MAPMRImetrics was quantified by estimating the empirical distributionsusing the wild bootstrap. We applied the wildbootstrap to both phantom data and human brain data, andobtain empirical distributions for theMAP-MRImetrics returnto-origin probability (RTOP), non-Gaussianity (NG) and propagatoranisotropy (PA).

    Results: We demonstrated the impact of diffusion acquisitionscheme (number of shells and number of measurementsper shell) on the uncertainty of MAP-MRI metrics.We demonstrated how the uncertainty of these metrics canbe used to improve group analyses, and to compare differentpreprocessing pipelines. We demonstrated that withuncertainty considered, the results for a group analysis canbe different.

    Conclusion: Bootstrap derived uncertain measures provideadditional information to the MAP-MRI derived metrics, andshould be incorporated in ongoing and future MAP-MRIstudies to provide more extensive insight.

  • 3.
    Gu, Xuan
    et al.
    Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Faculty of Science & Engineering. Linköping University, Center for Medical Image Science and Visualization (CMIV).
    Sidén, Per
    Linköping University, Department of Computer and Information Science, The Division of Statistics and Machine Learning. Linköping University, Faculty of Science & Engineering.
    Wegmann, Bertil
    Linköping University, Department of Computer and Information Science, The Division of Statistics and Machine Learning. Linköping University, Faculty of Science & Engineering.
    Eklund, Anders
    Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Department of Computer and Information Science, The Division of Statistics and Machine Learning. Linköping University, Faculty of Science & Engineering. Linköping University, Center for Medical Image Science and Visualization (CMIV).
    Villani, Mattias
    Linköping University, Department of Computer and Information Science, The Division of Statistics and Machine Learning. Linköping University, Faculty of Science & Engineering.
    Knutsson, Hans
    Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Faculty of Science & Engineering. Linköping University, Center for Medical Image Science and Visualization (CMIV).
    Bayesian Diffusion Tensor Estimation with Spatial Priors2017In: CAIP 2017: Computer Analysis of Images and Patterns, 2017, Vol. 10424, p. 372-383Conference paper (Refereed)
    Abstract [en]

    Spatial regularization is a technique that exploits the dependence between nearby regions to locally pool data, with the effect of reducing noise and implicitly smoothing the data. Most of the currently proposed methods are focused on minimizing a cost function, during which the regularization parameter must be tuned in order to find the optimal solution. We propose a fast Markov chain Monte Carlo (MCMC) method for diffusion tensor estimation, for both 2D and 3D priors data. The regularization parameter is jointly with the tensor using MCMC. We compare FA (fractional anisotropy) maps for various b-values using three diffusion tensor estimation methods: least-squares and MCMC with and without spatial priors. Coefficient of variation (CV) is calculated to measure the uncertainty of the FA maps calculated from the MCMC samples, and our results show that the MCMC algorithm with spatial priors provides a denoising effect and reduces the uncertainty of the MCMC samples.

  • 4.
    Shakya, Snehlata
    et al.
    Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Faculty of Science & Engineering. Linköping University, Center for Medical Image Science and Visualization (CMIV).
    Gu, Xuan
    Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Faculty of Science & Engineering. Linköping University, Center for Medical Image Science and Visualization (CMIV).
    Batool, Nazre
    KTH, School of Technology and Health, Huddinge, Sweden.
    Özarslan, Evren
    Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Faculty of Science & Engineering. Linköping University, Center for Medical Image Science and Visualization (CMIV).
    Knutsson, Hans
    Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Faculty of Science & Engineering. Linköping University, Center for Medical Image Science and Visualization (CMIV).
    Multi-fiber Estimation and Tractography for Diffusion MRI using mixture of Non-central Wishart Distributions2017In: VCBM 17: Eurographics Workshop on Visual Computing for Biology and Medicine, The Eurographics Association , 2017, p. 1-5Conference paper (Refereed)
    Abstract [en]

    Multi-compartmental models are popular to resolve intra-voxel fiber heterogeneity. One such model is the mixture of central Wishart distributions. In this paper, we use our recently proposed model to estimate the orientations of crossing fibers within a voxel based on mixture of non-central Wishart distributions. We present a thorough comparison of the results from other fiber reconstruction methods with this model. The comparative study includes experiments on a range of separation angles between crossing fibers, with different noise levels, and on real human brain diffusion MRI data. Furthermore, we present multi-fiber visualization results using tractography. Results on synthetic and real data as well as tractography visualization highlight the superior performance of the model specifically for small and middle ranges of separation angles among crossing fibers.

  • 5.
    Gu, Xuan
    et al.
    Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Faculty of Science & Engineering. Linköping University, Center for Medical Image Science and Visualization (CMIV).
    Eklund, Anders
    Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Department of Computer and Information Science, The Division of Statistics and Machine Learning. Linköping University, Faculty of Science & Engineering. Linköping University, Center for Medical Image Science and Visualization (CMIV).
    Knutsson, Hans
    Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Faculty of Science & Engineering. Linköping University, Center for Medical Image Science and Visualization (CMIV).
    Repeated Tractography of a Single Subject: How High Is the Variance?2017In: Modeling, Analysis, and Visualization of Anisotropy / [ed] Thomas Schultz, Evren Özarslan, Ingrid Hotz, Springer, 2017, p. 331-354Chapter in book (Other academic)
    Abstract [en]

    We have investigated the test-retest reliability of diffusion tractography, using 32 diffusion datasets from a single healthy subject. Preprocessing was carried out using functions in FSL (FMRIB Software Library), and tractography was carried out using FSL and Dipy. The tractography was performed in diffusion space, using two seed masks (corticospinal and cingulum gyrus tracts) created from the JHU White-Matter Tractography atlas. The tractography results were then warped into MNI standard space by a linear transformation. The reproducibility of tract metrics was examined using the standard deviation, the coefficient of variation (CV) and the Dice similarity coefficient (DSC), which all indicated a high reproducibility. Our results show that the multi-fiber model in FSL is able to reveal more connections between brain areas, compared to the single fiber model, and that distortion correction increases the reproducibility.

1 - 5 of 5
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf