liu.seSearch for publications in DiVA
Endre søk
Link to record
Permanent link

Direct link
Alternativa namn
Publikasjoner (8 av 8) Visa alla publikasjoner
Arbring, T., Ivanov, A. I., Kiani, N., Bernacka Wojcik, I., Samuelsson, J., Saarela Unemo, H., . . . Simon, D. (2025). Miniaturized Iontronic Micropipettes for Precise and Dynamic Ionic Modulation of Neuronal and Astrocytic Activity. Small, 21(16), Article ID 2410906.
Åpne denne publikasjonen i ny fane eller vindu >>Miniaturized Iontronic Micropipettes for Precise and Dynamic Ionic Modulation of Neuronal and Astrocytic Activity
Vise andre…
2025 (engelsk)Inngår i: Small, ISSN 1613-6810, E-ISSN 1613-6829, Vol. 21, nr 16, artikkel-id 2410906Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The composition of the extracellular milieu can vary significantly under physiological and pathological conditions, thereby altering the functional set point of brain cells. While global changes in the extracellular milieu are known to affect network activity, a detailed understanding of how specific changes in ion species impact individual cells remains elusive. Current modulation methods involve the use of diluted salts, such as KCl, where lack of precise control complicates data interpretation. This study achieves enhanced resolution by using a miniaturized iontronic micropipette. The micropipette, with a tip filled with polyelectrolyte and an outlet size below 2 mu m, allows for on-demand ionic manipulation of single cells, without simultaneous co-delivery of solvents or other solutes. Electrical, chemical, and optical characterizations, supported by computational modeling, confirm the device's high spatial and temporal precision. Validated in hippocampal slices, the device demonstrates iontronic release of potassium ions (K+), with a low current (<200 nA), that effectively, rapidly, and reversibly modulates individually targeted neurons and astrocytes. These findings underscore the potential of iontronic micropipettes to elucidate the distinct responses of neuronal and glial cells to specific changes in the local extracellular milieu, offering insights for neuroscience research and therapeutic innovation.

sted, utgiver, år, opplag, sider
WILEY-V C H VERLAG GMBH, 2025
Emneord
cellular neuroscience; electrophoretic delivery; electrophysiology; ionic modulation; iontronics
HSV kategori
Identifikatorer
urn:nbn:se:liu:diva-212564 (URN)10.1002/smll.202410906 (DOI)001440046400001 ()40059561 (PubMedID)2-s2.0-105003406615 (Scopus ID)
Merknad

Funding Agencies|Knut and Alice Wallenberg Foundation through the Wallenberg Scholars and Wallenberg Launchpad (WALP) programs; European Research Council [834677]; Swedish Research Council [2018-06197]; Swedish Foundation for Strategic Research [RMX18-0083]; FLAG-ERA JTC2017 project EPIGRAPH [ANR-17-GRF2-0001]; Zenith (Career grant Theresia Arbring Sjoestroem); EU [101129720, 956325]

Tilgjengelig fra: 2025-03-26 Laget: 2025-03-26 Sist oppdatert: 2025-10-21bibliografisk kontrollert
Roy, A., Bersellini Farinotti, A., Arbring Sjöström, T., Abrahamsson, T., Cherian, D., Karaday, M., . . . Simon, D. (2023). Electrophoretic Delivery of Clinically Approved Anesthetic Drug for Chronic Pain Therapy. Advanced Therapeutics, 6(7), Article ID 2300083.
Åpne denne publikasjonen i ny fane eller vindu >>Electrophoretic Delivery of Clinically Approved Anesthetic Drug for Chronic Pain Therapy
Vise andre…
2023 (engelsk)Inngår i: Advanced Therapeutics, E-ISSN 2366-3987, Vol. 6, nr 7, artikkel-id 2300083Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Despite a range of available pain therapies, most patients report so-called “breakthrough pain.” Coupled with global issues like opioid abuse, there is a clear need for advanced therapies and technologies for safe and effective pain management. Here the authors demonstrate a candidate for such an advanced therapy: precise and fluid-flow-free electrophoretic delivery via organic electronic ion pumps (OEIPs) of the commonly used anesthetic drug bupivacaine. Bupivacaine is delivered to dorsal root ganglion (DRG) neurons in vitro. DRG neurons are a good proxy for pain studies as they are responsible for relaying ascending sensory signals from nociceptors (pain receptors) in the peripheral nervous system to the central nervous system. Capillary based OEIPs are used due to their probe-like and free-standing form factor, ideal for interfacing with cells. By delivering bupivacaine with the OEIP and recording dose versus response (Ca2+ imaging), it is observed that only cells close to the OEIP outlet (≤75 µm) are affected (“anaesthetized”) and at concentrations up to 10s of thousands of times lower than with bulk/bolus delivery. These results demonstrate the first effective OEIP deliveryof a clinically approved and widely used analgesic pharmaceutical, and thus are a major translational milestone for this technology.

sted, utgiver, år, opplag, sider
John Wiley & Sons, Ltd, 2023
Emneord
anesthetic, bupivacaine, calcium imaging, drug delivery, electrophoretic, ion exchange membrane
HSV kategori
Identifikatorer
urn:nbn:se:liu:diva-193517 (URN)10.1002/adtp.202300083 (DOI)000977943800001 ()2-s2.0-85154059805 (Scopus ID)
Merknad

Funding agencies: This work was supported by the Swedish Foundation for Strategic Research, the Knut and Alice Wallenberg Foundation, the Swedish Research Council, the European Research Council (AdG 2018 Magnus Berggren, 834677 and CoG 2019 Camilla Svensson, 866075), and Vinnova. Additional support was provided by the Swedish Government Strategic Research Area in Materials Science on Advanced Functional Materials at Linköping University (Faculty Grant SFO-Mat-LiU no. 2009-00971).

Tilgjengelig fra: 2023-05-03 Laget: 2023-05-03 Sist oppdatert: 2024-03-26bibliografisk kontrollert
Cherian, D., Roy, A., Farinotti, A. B., Abrahamsson, T., Arbring Sjöström, T., Tybrandt, K., . . . Simon, D. (2023). Flexible Organic Electronic Ion Pump Fabricated Using Inkjet Printing and Microfabrication for Precision In Vitro Delivery of Bupivacaine. Advanced Healthcare Materials, 12(24), Article ID 2300550.
Åpne denne publikasjonen i ny fane eller vindu >>Flexible Organic Electronic Ion Pump Fabricated Using Inkjet Printing and Microfabrication for Precision In Vitro Delivery of Bupivacaine
Vise andre…
2023 (engelsk)Inngår i: Advanced Healthcare Materials, ISSN 2192-2640, E-ISSN 2192-2659, Vol. 12, nr 24, artikkel-id 2300550Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The organic electronic ion pump (OEIP) is an on-demand electrophoretic drug delivery device, that via electronic to ionic signal conversion enables drug delivery without additional pressure or volume changes. The fundamental component of OEIPs is their polyelectrolyte membranes which are shaped into ionic channels that conduct and deliver ionic drugs, with high spatiotemporal resolution. The patterning of these membranes is essential in OEIP devices and is typically achieved using laborious micro processing techniques. Here, we report the development of an inkjet printable formulation of polyelectrolyte, based on a custom anionically functionalized hyperbranched polyglycerol (i-AHPG). This polyelectrolyte ink greatly simplifies the fabrication process, and is used in the production of free standing, OEIPs on flexible polyimide substrates. Both i-AHPG and the OEIP devices are characterized, exhibiting favorable iontronic characteristics of charge selectivity and ability to transport aromatic compounds. Further, the applicability of these technologies is demonstrated by transport and delivery of the pharmaceutical compound bupivacaine to dorsal root ganglion cells with high spatial precision and effective nerve-blocking, highlighting the applicability of these technologies for biomedical scenarios.

sted, utgiver, år, opplag, sider
John Wiley & Sons, 2023
Emneord
bioelectronics, flexible devices, inkjet printing, polyelectrolytes, polyimide
HSV kategori
Identifikatorer
urn:nbn:se:liu:diva-193520 (URN)10.1002/adhm.202300550 (DOI)001010551300001 ()37069480 (PubMedID)2-s2.0-85161982885 (Scopus ID)
Merknad

Funding: Swedish Foundation for Strategic Research; Knut and Alice Wallenberg Foundation; Swedish Research Council; European Research Council [834677]; Swedish Government Strategic Research Area in Materials Science on Advanced Functional Materials at Linkoping University (Faculty Grant SFO-Mat-LiU) [2009-00971]; Vinnova

Tilgjengelig fra: 2023-05-03 Laget: 2023-05-03 Sist oppdatert: 2025-06-03bibliografisk kontrollert
Arbring Sjöström, T., Ivanov, A. I., Bernard, C., Tybrandt, K., Poxson, D., Simon, D. T. & Berggren, M. (2021). Design and Operation of Hybrid Microfluidic Iontronic Probes for Regulated Drug Delivery. Paper presented at 2021/01/18. Advanced Materials Technologies, 6(2), Article ID 2001006.
Åpne denne publikasjonen i ny fane eller vindu >>Design and Operation of Hybrid Microfluidic Iontronic Probes for Regulated Drug Delivery
Vise andre…
2021 (engelsk)Inngår i: Advanced Materials Technologies, E-ISSN 2365-709X, Vol. 6, nr 2, artikkel-id 2001006Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Highly controlled drug delivery devices play an increasingly important role in the development of new neuroengineering tools. Stringent - and sometimes contradicting - demands are placed on such devices, ranging from robustness in freestanding devices, to overall device miniaturization, while maintaining precise spatiotemporal control of delivery with high chemical specificity and high on/off ratio. Here, design principles of a hybrid microfluidic iontronic probe that uses flow for long-range pressure-driven transport in combination with an iontronic tip that provides electronically fine-tuned pressure-free delivery are explored. Employing a computational model, the effects of decoupling the drug reservoir by exchanging a large passive reservoir with a smaller microfluidic system are reported. The transition at the microfluidic-iontronic interface is found to require an expanded ion exchange membrane inlet in combination with a constant fluidic flow, to allow a broad range of device operation, including low source concentrations and high delivery currents. Complementary to these findings, the free-standing hybrid probe monitored in real time by an external sensor is demonstrated. From these computational and experimental results, key design principles for iontronic devices are outlined that seek to use the efficient transport enabled by microfluidics, and further, key observations of hybrid microfluidic iontronic probes are explained.

sted, utgiver, år, opplag, sider
Hoboken, New Jersey: John Wiley & Sons, 2021
Emneord
bioelectronics, drug delivery, iontronics, microfluidics, organic electronics
HSV kategori
Identifikatorer
urn:nbn:se:liu:diva-172686 (URN)10.1002/admt.202001006 (DOI)000607538700001 ()
Konferanse
2021/01/18
Forskningsfinansiär
Swedish Foundation for Strategic Research Knut and Alice Wallenberg FoundationVinnovaSwedish Research CouncilEU, European Research Council, 2018
Merknad

Additional Funding agencies: FLAG‐ERA. Grant Number: JTC2017; EPIGRAPH. Grant Number: ANR‐17‐GRF2‐0001; Swedish Government Strategic Research Area in Materials Science on Advanced Functional Materials at Linköping University. Grant Number: 2009‐00971; A*MIDEX ION. Grant Number: 2IONXXID/REID/ID17HRU208

Tilgjengelig fra: 2021-01-18 Laget: 2021-01-18 Sist oppdatert: 2025-02-09bibliografisk kontrollert
Arbring Sjöström, T. (2020). Organic Bioelectronics for Neurotransmitter Release at the Speed of Life. (Doctoral dissertation). Linköping: Linköping University Electronic Press
Åpne denne publikasjonen i ny fane eller vindu >>Organic Bioelectronics for Neurotransmitter Release at the Speed of Life
2020 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

The signaling dynamics in neuronal networks includes processes ranging from lifelong neuromodulation to direct synaptic neurotransmission. In chemical synapses, the time delay it takes to pass a signal from one neuron to the next lasts for less than a millisecond. At the post-synaptic neuron, further signaling is either up- or down-regulated, dependent on the specific neurotransmitter and receptor. While this up- and down-regulation of signals usually runs perfectly well and enables complex performance, even a minor dysfunction of this signaling system can cause major complications, in the shape of neurological disorders. The field of organic bioelectronics has the ability to interface neurons with high spatiotemporal recording and stimulation techniques. Local chemical stimulation, i.e. local release of neurotransmitters, enables the possibility of artificially altering the chemical environment in dysfunctional signaling pathways to regain or restore neural function. To successfully interface the biological nervous system with electronics, a range of demands must be met. Organic bioelectronic techniques and materials are capable of reaching the demands on the biological as well as the electronic side of the interface. These demands span from high performance biocompatible materials, to miniaturized and specific device architectures, and high dose control on demand within milliseconds.

The content of this thesis is a continuation of the development of organic bioelectronic devices for neurotransmitter delivery. Organic materials are utilized to electrically control the dose of charged neurotransmitters by translating electric charge into controlled artificial release. The first part of the thesis, Papers 1 and 2, includes further development of the resistor-type release device called the organic electronic ion pump. This part includes material evaluation, microfluidic incorporation, and device design considerations. The aim for the second part of this thesis, Papers 3 and 4, is to enhance temporal performance, i.e. reduce the delay between electrical signal and neurotransmitter delivery to corresponding delay in biological neural signaling, while retaining tight dosage control. Diffusion of neurotransmitters between nerve cells is a slow process, but since it is restricted to short distances, the total time delay is short. In our organic bioelectronic devices, several orders of magnitude in speed can be gained by switching from lateral to vertical delivery geometries. This is realized by two different types of vertical diodes combined with a lateral preload and waste configuration. The vertical diode assembly was further expanded with a control electrode that enables individual addressing in each of several combined release sites. These integrated circuits allow for release of neurotransmitters with high on/off release ratios, approaching delivery times on par with biological neurotransmission.

sted, utgiver, år, opplag, sider
Linköping: Linköping University Electronic Press, 2020. s. 77
Serie
Linköping Studies in Science and Technology. Dissertations, ISSN 0345-7524 ; 2104
HSV kategori
Identifikatorer
urn:nbn:se:liu:diva-171789 (URN)10.3384/diss.diva-171789 (DOI)9789179297558 (ISBN)
Disputas
2021-01-13, Online and K1 (kåkenhus) Please contact Jennie Jordenlöv, jennie.jordenlov@liu.se to get the Zoom link, Campus Norrköping, Norrköping, 14:00 (engelsk)
Opponent
Veileder
Tilgjengelig fra: 2020-12-07 Laget: 2020-12-07 Sist oppdatert: 2021-01-18bibliografisk kontrollert
Jakešová, M., Arbring, T., Đerek, V., Poxson, D., Berggren, M., Glowacki, E. & Simon, D. T. (2019). Wireless organic electronic ion pumps driven by photovoltaics. npj Flexible Electronics, 3(1), 14-14
Åpne denne publikasjonen i ny fane eller vindu >>Wireless organic electronic ion pumps driven by photovoltaics
Vise andre…
2019 (engelsk)Inngår i: npj Flexible Electronics, ISSN 2397-4621, Vol. 3, nr 1, s. 14-14Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The organic electronic ion pump (OEIP) is an emerging bioelectronic technology for on-demand and local delivery of pharmacologically active species, especially targeting alkali ions, and neurotransmitters. While electrical control is advantageous for providing precise spatial, temporal, and quantitative delivery, traditionally, it necessitates wiring. This complicates implantation. Herein, we demonstrate integration of an OEIP with a photovoltaic driver on a flexible carrier, which can be addressed by red light within the tissue transparency window. Organic thin-film bilayer photovoltaic pixels are arranged in series and/or vertical tandem to provide the 2.5–4.5 V necessary for operating the high-resistance electrophoretic ion pumps. We demonstrate light-stimulated transport of cations, ranging in size from protons to acetylcholine. The device, laminated on top of the skin, can easily be driven with a red LED emitting through a 1.5-cm-thick finger. The end result of our work is a thin and flexible integrated wireless device platform.

sted, utgiver, år, opplag, sider
Nature Publishing Group, 2019
HSV kategori
Identifikatorer
urn:nbn:se:liu:diva-160118 (URN)10.1038/s41528-019-0060-6 (DOI)000619054200014 ()
Tilgjengelig fra: 2019-09-05 Laget: 2019-09-05 Sist oppdatert: 2024-11-14bibliografisk kontrollert
Williamson, A., Rivnay, J., Kergoat, L., Jonsson, A., Inal, S., Uguz, I., . . . Bernard, C. (2015). Controlling Epileptiform Activity with Organic Electronic Ion Pumps. Advanced Materials, 27(20), 3138-3144
Åpne denne publikasjonen i ny fane eller vindu >>Controlling Epileptiform Activity with Organic Electronic Ion Pumps
Vise andre…
2015 (engelsk)Inngår i: Advanced Materials, ISSN 0935-9648, E-ISSN 1521-4095, Vol. 27, nr 20, s. 3138-3144Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

In treating epilepsy, the ideal solution is to act at a seizure's onset, but only in the affected regions of the brain. Here, an organic electronic ion pump is demonstrated, which directly delivers on-demand pure molecules to specific brain regions. State-of-the-art organic devices and classical pharmacology are combined to control pathological activity in vitro, and the results are verified with electrophysiological recordings.

sted, utgiver, år, opplag, sider
Wiley-VCH Verlag, 2015
Emneord
Organic Bioelectronics, Organic Electronic Ion Pump, PEDOT:PSS, Neuroengineering
HSV kategori
Identifikatorer
urn:nbn:se:liu:diva-119247 (URN)10.1002/adma.201500482 (DOI)000354823600002 ()25866154 (PubMedID)
Merknad

Funding Agencies|European Union [602102]; A*MIDEX [A_M-AAP-ID-13-24-130531-16.31-BERNARD-HLS]; Swedish Innovation Office (VINNOVA); Swedish Research Council [621-2011-3517]; Knut and Alice Wallenberg Foundation [2012.0302]; National Science Foundation [DMR-1105253]; ANR [ANR-13-BSV5-0019-01]; Fondation pour la Recherche Medicale [DBS20131128446]; Fondation de lAvenir; Onnesjo Foundation; Region PACA; Microvitae Technologies; Orthogonal, Inc.; Marie Curie Fellowships

Tilgjengelig fra: 2015-06-15 Laget: 2015-06-12 Sist oppdatert: 2017-11-22
Nyman, E., Lindgren, I., Lövfors, W., Lundengård, K., Cervin, I., Arbring, T., . . . Cedersund, G. (2015). Mathematical modeling improves EC50 estimations from classical dose–response curves. The FEBS Journal, 282(5), 951-962
Åpne denne publikasjonen i ny fane eller vindu >>Mathematical modeling improves EC50 estimations from classical dose–response curves
Vise andre…
2015 (engelsk)Inngår i: The FEBS Journal, ISSN 1742-464X, E-ISSN 1742-4658, Vol. 282, nr 5, s. 951-962Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The beta-adrenergic response is impaired in failing hearts. When studying beta-adrenergic function in vitro, the half-maximal effective concentration (EC50) is an important measure of ligand response. We previously measured the in vitro contraction force response of chicken heart tissue to increasing concentrations of adrenaline, and observed a decreasing response at high concentrations. The classical interpretation of such data is to assume a maximal response before the decrease, and to fit a sigmoid curve to the remaining data to determine EC50. Instead, we have applied a mathematical modeling approach to interpret the full dose–response curvein a new way. The developed model predicts a non-steady-state caused by a short resting time between increased concentrations of agonist, which affect the dose–response characterization. Therefore, an improved estimate of EC50 may be calculated using steady-state simulations of the model. The model-based estimation of EC50 is further refined using additional time resolved data to decrease the uncertainty of the prediction. The resulting model-based EC50 (180–525 nM) is higher than the classically interpreted EC50 (46–191 nM). Mathematical modeling thus makes it possible to reinterpret previously obtained datasets, and to make accurate estimates of EC50 even when steady-state measurements are not experimentally feasible.

Emneord
adrenaline; cardiac b-adrenergic signaling; dynamic mathematical modeling; EC50; ordinary differential equations
HSV kategori
Identifikatorer
urn:nbn:se:liu:diva-114788 (URN)10.1111/febs.13194 (DOI)000350650200010 ()25586512 (PubMedID)
Tilgjengelig fra: 2015-03-04 Laget: 2015-03-04 Sist oppdatert: 2023-12-28
Organisasjoner
Identifikatorer
ORCID-id: ORCID iD iconorcid.org/0000-0001-7729-0251