liu.seSearch for publications in DiVA
Change search
Link to record
Permanent link

Direct link
Lood, Yvonne
Publications (3 of 3) Show all publications
Lethin, K., Aardal-Eriksson, E., Lood, Y., Ekman, B. & Wahlberg, J. (2024). Effects of 12 Months' Treatment with Testosterone Undecanoate on Markers for Erythropoietic Activity and Safety Aspects in Transgender and Cisgender Hypogonadal Men. The Journal of Applied Laboratory Medicine, 9(2), 223-236
Open this publication in new window or tab >>Effects of 12 Months' Treatment with Testosterone Undecanoate on Markers for Erythropoietic Activity and Safety Aspects in Transgender and Cisgender Hypogonadal Men
Show others...
2024 (English)In: The Journal of Applied Laboratory Medicine, ISSN 2576-9456, E-ISSN 2475-7241, Vol. 9, no 2, p. 223-236Article in journal (Refereed) Published
Abstract [en]

Background To investigate the erythropoietic activity and safety aspects of testosterone undecanoate (TU) injections in transgender men, assigned female at birth.Methods Twenty-three men (13 hypogonadal cisgender men and 10 transgender men) who initiated TU at the study start (naive) and 15 men (10 hypogonadal cisgender men and 5 transgender men) on steady-state treatment with TU (non-naive) were included in this prospective 1-year observational study. A control group of 32 eugonadal cisgender men was investigated once at baseline. Complete blood count, testosterone in serum and saliva, and plasma lipids, and liver enzymes were assessed.Results For naive transgender men, a significant increase in hemoglobin concentration was noted (mean (SD)), 141 (8) g/L to 151 (13) g/L, while no increase was seen in naive hypogonadal cisgender men. At the end of the study, naive transgender men exhibited comparable levels of hemoglobin, hematocrit, and testosterone levels in serum and saliva to hypogonadal cisgender men, as well as to the eugonadal cisgender men. During the study, HDL-cholesterol decreased significantly in naive transgender men, 1.4 (0.4) mmol/L to 1.2 (0.4) mmol/L, P = 0.03, whereas no significant change was noted in naive hypogonadal cisgender men. Liver enzymes remained unchanged in all groups.Conclusions After 12 months of treatment with TU in naive transgender men, hemoglobin and hematocrit increased to levels within the cisgender male reference range. A slight decrease in HDL-cholesterol was seen in naive transgender men but liver enzymes remained unchanged.

Place, publisher, year, edition, pages
OXFORD UNIV PRESS INC, 2024
National Category
Clinical Medicine
Identifiers
urn:nbn:se:liu:diva-199994 (URN)10.1093/jalm/jfad096 (DOI)001122369700001 ()38085088 (PubMedID)2-s2.0-85186743609 (Scopus ID)
Note

Funding Agencies|Linkoping University, Sweden, ALF [ROE-129081]; Medical Research Council of Southeast Sweden [FORSS-37761]

Available from: 2024-01-11 Created: 2024-01-11 Last updated: 2025-08-13Bibliographically approved
Lood, Y., Aardal, E., Ahlner, J., Ärlemalm, A., Carlsson, B., Ekman, B., . . . Josefsson, M. (2021). Determination of testosterone in serum and saliva by liquid chromatography-tandem mass spectrometry: An accurate and sensitive method applied on clinical and forensic samples. Journal of Pharmaceutical and Biomedical Analysis, 195, Article ID 113823.
Open this publication in new window or tab >>Determination of testosterone in serum and saliva by liquid chromatography-tandem mass spectrometry: An accurate and sensitive method applied on clinical and forensic samples
Show others...
2021 (English)In: Journal of Pharmaceutical and Biomedical Analysis, ISSN 0731-7085, E-ISSN 1873-264X, Vol. 195, article id 113823Article in journal (Refereed) Published
Abstract [en]

A highly sensitive and accurate electrospray liquid chromatography tandem-mass spectrometry (ESI-LC–MS/MS) method for determination of testosterone in human serum and saliva was developed and validated. Accurate quantification of testosterone in human matrices is essential in diagnosis and management of androgen status in men, women and children, and in forensic investigations of suspected abuse of anabolic androgenic steroids. Chromatography was performed on an HSS-T3 C18 column with a total run-time of 5.5 min. The tandem mass spectrometry was operated in positive electrospray ionization mode with multiple reaction monitoring. Serum and saliva samples of 200 μL, were prepared by solid-phase extraction using a 96-well plate following precipitation with 200 μL methanol. 13C labeled testosterone was used as internal standard for quantification. The standard curve was linear within the range of 4−1000 pg/mL and the limit of quantification of both serum and salivary testosterone was 4 pg/mL. Accuracy were 99–101 % and 93–95 % with between-run imprecision in serum and saliva, respectively, and inter- and intra-assay coefficients of variation were less than 9.2 %. The method proved to be applicable for determination of testosterone over a wide range of concentrations in serum and saliva samples from clinical patients with various androgen disorders, healthy male and female adults as well as from forensic cases.

Place, publisher, year, edition, pages
Elsevier, 2021
Keywords
Testosterone, Serum, Saliva, LC–MS/MS
National Category
Analytical Chemistry
Identifiers
urn:nbn:se:liu:diva-173145 (URN)10.1016/j.jpba.2020.113823 (DOI)000610841900007 ()113823 (Local ID)113823 (Archive number)113823 (OAI)
Note

Funding:Strategic Area in Forensic Science; Forskningsradet i Sydostra Sverige (FORSS) [713391]

Available from: 2021-02-04 Created: 2021-02-04 Last updated: 2022-05-23Bibliographically approved
Lood, Y., Aardal, E., Gustavsson, S., Prasolov, I., Josefsson, M. & Ahlner, J. (2021). False negative results in testosterone doping in forensic cases: Sensitivity of the urinary detection criteria T/E and T/LH. Paper presented at 2021/08/17. Drug Testing and Analysis, n/a(n/a)
Open this publication in new window or tab >>False negative results in testosterone doping in forensic cases: Sensitivity of the urinary detection criteria T/E and T/LH
Show others...
2021 (English)In: Drug Testing and Analysis, ISSN 1942-7603, E-ISSN 1942-7611, Vol. n/a, no n/aArticle in journal (Refereed) Published
Abstract [en]

At the Swedish national forensic toxicology laboratory, a measured testosterone/epitestosterone (T/E) ratio?≥?12 together with testosterone/luteinizing hormone (T/LH) in urine?>?400?nmol/IU is considered as a proof of exogenous testosterone administration. However, according to the rules of the World Anti-Doping Agency (WADA), samples with T/E ratio?>?4 are considered suspicious and shall be further analysed by gas chromatography?combustion?isotope ratio mass spectrometry (GC-C-IRMS) to confirm the origin of testosterone and its metabolites. The aim of this study was to investigate the possibility of false negative results and to estimate the frequency of negative results using the current criteria for detection of abuse of testosterone in forensic investigations. Urine and serum samples were collected by the police at suspected infringement of the doping law in Sweden. Fifty-eight male subjects were included in the study. Urinary testosterone was determined by gas chromatography?mass spectrometry (GC?MS), serum testosterone and LH?by immunoassay. The origin of testosterone and its metabolites was confirmed by means of GC-C-IRMS. Twenty-six of the 57 analysed subjects tested positive for exogenous testosterone using the criteria T/E?≥?12 combined with T/LH?>?400?nmol/IU. The IRMS analyses confirmed 47 positives; thus, 21 were considered false negatives. Negative predictive value was 32% (95% confidence interval [CI]: 16%?50%) and sensitivity 55%. No false positive subjects were found. The number of false negative cases using the current criteria for the detection of testosterone abuse and hence the low sensitivity indicates a need to discuss introduction of new strategies in forensic doping investigations.

Place, publisher, year, edition, pages
John Wiley & Sons, Ltd, 2021
Keywords
doping, GC-C-IRMS, LH, T/E, testosterone
National Category
Forensic Science
Identifiers
urn:nbn:se:liu:diva-178310 (URN)10.1002/dta.3125 (DOI)000674047600001 ()
Conference
2021/08/17
Note

Funding agencies: Strategic Research Area in Forensic Science (2019), Sweden

Available from: 2021-08-17 Created: 2021-08-17 Last updated: 2022-06-17Bibliographically approved
Organisations

Search in DiVA