liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Modeling of a Novel Biosensor with Integrated Mass and Electrochemical Sensing Capabilities
IIUM, Malaysia.
IIUM, Malaysia.
IIUM, Malaysia.
Linköpings universitet, Institutionen för fysik, kemi och biologi, Biosensorer och bioelektronik. Linköpings universitet, Tekniska fakulteten.ORCID-id: 0000-0003-3274-6029
2016 (engelsk)Inngår i: 2016 IEEE EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), IEEE , 2016, s. 420-425Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Rapid development in technology and society has generated diverse developments in many fields including biosensors in healthcare application. Here, the design of integrated biosensor comprises mass sensing (Quartz Crystal Microbalance) and electrochemistry sensing (Electrochemical Impedance Spectroscopy, EIS and Cyclic Voltammetry, CV) will be presented. The integrated sensor system is developed based on the innovative use of the top electrode of a quartz crystal microbalance (QCM) resonator as a working electrode for the electrochemistry technique. Integration of QCM with the electrochemistry technique is realized by fabricating a semicircular counter electrode near the upper electrode on the same side of the quartz crystal. CV and EIS measurement was conducted using finite element modeling, COMSOL (TM) 5.2 with the probe marker of 1 mmol L-1 of [Fe(CN)(6)](3-/4-). CV test was done to study the effect between increasing scan rate and peak current (anodic and cathodic) in observing the reversible electrochemical process. This observation is crucial in ensuring the electrochemical processes follow the Randles-Sevcik equation in characterizing the platform changes behavior. Later, EIS test was performed in order to measure the radius of the semicircle which reflects the charge transfer resistance (R-CT) of the redox marker. To show the effectiveness of this sensor, gold immobilization surface was electrochemically simulated and reported. Thus, an ultra-sensitive biosensor that capable to produce multi-analysis in the detection of biological targets in terms of electrochemical change of electrode interfaces, which is the crucial step towards the engineering of advanced bioelectronics.

sted, utgiver, år, opplag, sider
IEEE , 2016. s. 420-425
Serie
IEEE EMBS Conference on Biomedical Engineering and Sciences, ISSN 2374-3220
Emneord [en]
Quartz Crystal Microbalance; Electrochemical Impedance Spectroscopy; Cyclic Voltammetry; AT-cut Quartz
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-138334DOI: 10.1109/IECBES.2016.7843485ISI: 000400605700083ISBN: 978-1-4673-7791-1 (tryckt)OAI: oai:DiVA.org:liu-138334DiVA, id: diva2:1109013
Konferanse
IEEE EMBS Conference on Biomedical Engineering and Sciences (IECBES)
Tilgjengelig fra: 2017-06-13 Laget: 2017-06-13 Sist oppdatert: 2017-06-13

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Søk i DiVA

Av forfatter/redaktør
Mak, Wing Cheung
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric

doi
isbn
urn-nbn
Totalt: 444 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf