liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
No Difference in Periprosthetic Bone Loss and Fixation Between a Standard-Length Stem and a Shorter Version in Cementless Total Hip Arthroplasty. A Randomized Controlled Trial
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Avdelningen för Kirurgi, Ortopedi och Onkologi. Linköpings universitet, Hälsouniversitetet. Region Östergötland, Centrum för kirurgi, ortopedi och cancervård, Ortopedkliniken i Linköping.ORCID-id: 0000-0003-0677-9265
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Ortopedi och idrottsmedicin. Linköpings universitet, Hälsouniversitetet. Region Östergötland, Centrum för kirurgi, ortopedi och cancervård, Ortopedkliniken i Linköping.
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Avdelningen för Kirurgi, Ortopedi och Onkologi. Linköpings universitet, Hälsouniversitetet.
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Avdelningen för Kirurgi, Ortopedi och Onkologi. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Centrum för kirurgi, ortopedi och cancervård, Ortopedkliniken i Linköping.
2017 (engelsk)Inngår i: The Journal of Arthroplasty, ISSN 0883-5403, E-ISSN 1532-8406, Vol. 32, nr 4, s. 1220-1226Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Background: Cementless femoral stems in total hip arthroplasty provide dependable clinical and radiographic results in the treatment of osteoarthritis. Stem length might affect the preservation of proximal bone stock and stability. We hypothesized that a shorter stem decreases proximal bone loss without affecting implant stability. Methods: We randomly assigned 60 patients aged between 50 and 70 years to either a standard cementless femoral stem or a 35-mm shorter version. Patients were followed with dual-energy X-ray absorptiometry, radiostereometric analysis, Harris hip score, Western Ontario and McMaster Universities Osteoarthritis Index score, and clinical follow-up at 3, 6, 12, and 24 months. The trial is registered on ClinicalTrials. gov/. Results: After 24 months, short stems had on average 3.8% (95% confidence interval, 1.2%-8.9%) more bone loss in zone 1 compared to standard stems (P - .14). In zone 7, the bone loss was on average 6.5% (95% confidence interval, 6.6%-19.7%) higher compared to standard stems (P - .33). After 24 months, standard stems had migrated 0.93 mm (range, 0.25-4.66 mm) and short stems 0.93 mm (range, 0.17-2.96 mm; Student t-test after log transformation, P - .3). Patient-reported outcome measures were similar in both groups. One patient in the standard stem group was diagnosed with infection, one with a posterior dislocation, and one with a deep venous thrombosis. No stems were revised. Conclusion: There were no statistically significant differences in periprosthetic bone loss or fixation between the stems at 24 months. (C) 2016 Elsevier Inc. All rights reserved.

sted, utgiver, år, opplag, sider
CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS , 2017. Vol. 32, nr 4, s. 1220-1226
Emneord [en]
total hip arthroplasty; short stem; radiostereometric analysis; dual-energy X-ray absorptiometry; cementless stem
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-138287DOI: 10.1016/j.arth.2016.11.015ISI: 000401125600032PubMedID: 27993496OAI: oai:DiVA.org:liu-138287DiVA, id: diva2:1109068
Tilgjengelig fra: 2017-06-13 Laget: 2017-06-13 Sist oppdatert: 2019-05-27

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Person

Palm, Lars

Søk i DiVA

Av forfatter/redaktør
Schilcher, JörgIvarsson, IngemarPerlbach, RicoPalm, Lars
Av organisasjonen
I samme tidsskrift
The Journal of Arthroplasty

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 970 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf