liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Evaluation of a multi-layer diffuse reflectance spectroscopy system using optical phantoms
Linköpings universitet, Institutionen för medicinsk teknik, Avdelningen för medicinsk teknik. Linköpings universitet, Tekniska fakulteten. Perimed AB, Sweden.ORCID-id: 0000-0002-3454-6576
University of Calif Irvine, CA USA; University of Calif Irvine, CA USA.
University of Calif Irvine, CA USA.
Linköpings universitet, Institutionen för medicinsk teknik, Avdelningen för medicinsk teknik. Linköpings universitet, Tekniska fakulteten. University of Calif Irvine, CA USA; University of Calif Irvine, CA USA.ORCID-id: 0000-0002-7299-891X
2017 (engelsk)Inngår i: DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES X, SPIE-INT SOC OPTICAL ENGINEERING , 2017, Vol. 10056, artikkel-id UNSP 100560GKonferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

A fiber probe-based device for assessing microcirculatory parameters, especially red blood cell (RBC) tissue fraction, their oxygen saturation and speed resolved perfusion, has been evaluated using state-of-the-art multi-layer tissue simulating phantoms. The device comprises both diffuse reflectance spectroscopy (DRS) at two source-detector separations (0.4 and 1.2 mm) and laser Doppler flowmetry (LDF) and use an inverse Monte Carlo method for identifying the parameters of a multi-layered tissue model. First, model parameters affecting scattering, absorption and geometrical parameters are fitted to measured DRS spectra, then speed parameters are fitted to LDF spectra. In this paper, the accuracy of the spectral parameters is evaluated. The measured spectral shapes at the two source-detector separations were in good agreement with forward calculated spectral shapes. In conclusion, the multi-layer skin model based on spectral features of the included chromophores, can reliably estimate the tissue fraction of RBC, its oxygen saturation and the reduced scattering coefficient spectrum of the tissue. Furthermore, it was concluded that some freedom in the relative intensity difference between the two DRS channels is necessary in order to compensate for non-modeled surface structure effects.

sted, utgiver, år, opplag, sider
SPIE-INT SOC OPTICAL ENGINEERING , 2017. Vol. 10056, artikkel-id UNSP 100560G
Serie
Proceedings of SPIE, ISSN 0277-786X
Emneord [en]
Diffuse reflectance spectroscopy; Optical phantoms; Multilayered tissue model; Microcirculation; Surface structure; Inverse Monte Carlo; Sampling volume
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-140077DOI: 10.1117/12.2249562ISI: 000407038900008ISBN: 978-1-5106-0553-4 (tryckt)ISBN: 978-1-5106-0554-1 (digital)OAI: oai:DiVA.org:liu-140077DiVA, id: diva2:1136580
Konferanse
Conference on Design and Quality for Biomedical Technologies X
Merknad

Funding Agencies|Swedens innovation agency VINNOVA [201602211]; VINNMER Marie Curie Academy Outgoing [2015-01503]; Fulbright Visiting Scholar; Beckman Foundation; NIH from NIBIB [P41EB015890]

Tilgjengelig fra: 2017-08-28 Laget: 2017-08-28 Sist oppdatert: 2025-02-09

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Søk i DiVA

Av forfatter/redaktør
Fredriksson, IngemarStrömberg, Tomas
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric

doi
isbn
urn-nbn
Totalt: 514 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf