liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Quality control in cone-beam computed tomography (CBCT): EFOMP-ESTRO-IAEA protocol
Helmholtz Zentrum München, Munich, Germany.ORCID-id: 0000-0003-3227-0032
ASST Grande Ospedale Metropolitano Niguarda, Milano, Italy.
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Centrum för kirurgi, ortopedi och cancervård, Radiofysikavdelningen US. The Skandion Clinic, Uppsala, Sweden.ORCID-id: 0000-0001-8171-2541
A.O.U. Città della Salute e della Scienza, Torino, Italy.ORCID-id: 0000-0003-3078-5438
Vise andre og tillknytning
2017 (engelsk)Rapport (Fagfellevurdert)
Abstract [en]

Quality control of cone-beam computed tomography (CBCT) systems is an essential part of quality assurance to periodically check that quality requirements are met, reduce uncertainties and errors and reduce the likelihood of accidents and incidents. Radiation exposure levels must be measured to ensure that patient doses associated with CBCT examinations are kept as low as reasonably achievable consistent with the required diagnostic information. The main purpose of this document is to present procedures for quality control of CBCT systems used for dental, radiotherapy, interventional radiology and guided surgery applications.

The ‘Quality control in cone-beam computed tomography’ is the second of the series on quality control protocols. The European Federation of Organizations for Medical Physics (EFOMP) published the first document on ‘Quality Controls in digital mammography’ in 2015. These books are freely available online at efomp.org and can be used as both, in-depth working guides to everyday practice and an up-to-date reference sources for medical physicists engaged in quality control of medical imaging systems.

This book is the result of the experience and knowledge of an international group of leading medical physics experts and an excellent illustration of the synergy that can be achieved when every team member works at their best and collaboratively follows the whole process through its completion.

sted, utgiver, år, opplag, sider
European Federation of Οrganisations for Medical Physics , 2017. , s. 151
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-140712DOI: 10.19285/CBCTEFOMP.V1.0.2017.06OAI: oai:DiVA.org:liu-140712DiVA, id: diva2:1139600
Tilgjengelig fra: 2017-09-08 Laget: 2017-09-08 Sist oppdatert: 2017-09-15bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Person

Dasu, Alexandru

Søk i DiVA

Av forfatter/redaktør
de las Heras Gala, HugoDasu, AlexandruRampado, OsvaldoDelis, HarryGershan, VesnaDelpon, GregoryPeterlin, PrimožGarayoa Roca, Julia
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 923 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf