liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Optical Measurements during Deep Brain Stimulation Lead Implantation: Safety Aspects
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Avdelningen för neuro- och inflammationsvetenskap. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Sinnescentrum, Neurokirurgiska kliniken US.
School of Life Sciences FHNW Institute for Medical and Analytical Technologies.
Linköpings universitet, Institutionen för medicinsk teknik, Avdelningen för medicinsk teknik. Linköpings universitet, Tekniska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. (MINT)ORCID-id: 0000-0002-0012-7867
2017 (engelsk)Inngår i: Stereotactic and Functional Neurosurgery, ISSN 1011-6125, E-ISSN 1423-0372, Vol. 95, nr 6, s. 392-399Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

BACKGROUND: Intracerebral hemorrhage (ICH) is the most feared complication in deep brain stimulation (DBS) surgery. The aim of the study was to evaluate patient safety and outcome using laser Doppler flowmetry (LDF) as guidance tool during DBS implantations.

METHODS: An LDF probe adapted for the stereotactic system was used as guide for creation of the trajectory. The microcirculation along 83 preplanned trajectories was measured with the guide during DBS surgery for movement disorders. The microvascular blood flow levels were investigated for all measurement positions. Medical record and postoperative radiology were retrospectively reviewed.

RESULTS: Of 2,963 measurement positions, 234 (7.9%) showed at least a doubled blood flow compared to the surrounding tissue. Of these 2.2% had a more than 5 times higher blood flow in front of the probe tip. Along 1 trajectory, a small ICH was detected during surgery. Increased blood flow was more common close to sulci and verticals.

CONCLUSION: Real-time LDF measurement of the microcirculation using a forward-looking probe during DBS surgery can detect blood flow peaks and further minimize the risk of developing ICH. No separate guide tube is necessary as the probe also creates the trajectory for the DBS lead.

sted, utgiver, år, opplag, sider
Basel: S. Karger, 2017. Vol. 95, nr 6, s. 392-399
Emneord [en]
Deep brain stimulation, Intracerebral hemorrhage, Laser Doppler flowmetry, Safety
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-144203DOI: 10.1159/000484944ISI: 000426220600005PubMedID: 29301132Scopus ID: 2-s2.0-85040026633OAI: oai:DiVA.org:liu-144203DiVA, id: diva2:1172622
Merknad

Funding agencies: Swedish Research Council [621-2013-6078]; Parkinson Foundation at Linkoping University

Tilgjengelig fra: 2018-01-10 Laget: 2018-01-10 Sist oppdatert: 2018-09-07bibliografisk kontrollert

Open Access i DiVA

fulltext(674 kB)486 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 674 kBChecksum SHA-512
7e46d6ce78ce9e61acd40f83d3c96f30dafea48fe2d0b04853ad14f5ba903a7cde7ebc1ccffbc23c92f6b93be1414db12024b3b0fb4ec63ee98f0af5326bc8c1
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Zsigmond, PeterWårdell, Karin

Søk i DiVA

Av forfatter/redaktør
Zsigmond, PeterWårdell, Karin
Av organisasjonen
I samme tidsskrift
Stereotactic and Functional Neurosurgery

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 486 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 291 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf