Soft Electronic Strain Sensor with Chipless Wireless Readout: Toward Real-Time Monitoring of Bladder Volume
Swiss Fed Inst Technol, Switzerland.
Swiss Fed Inst Technol, Switzerland.
Linköpings universitet, Institutionen för teknik och naturvetenskap, Fysik och elektroteknik. Linköpings universitet, Tekniska fakulteten. Swiss Fed Inst Technol, Switzerland.ORCID-id: 0000-0002-9845-446X
Swiss Fed Inst Technol, Switzerland.
Vise andre og tillknytning
2018 (engelsk)Inngår i: Advanced Materials Technologies, E-ISSN 2365-709X, Vol. 3, nr 6, artikkel-id 1800031Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Sensing mechanical tissue deformation in vivo can provide detailed information on organ functionality and tissue states. To bridge the huge mechanical mismatch between conventional electronics and biological tissues, stretchable electronic systems have recently been developed for interfacing tissues in healthcare applications. A major challenge for wireless electronic implants is that they typically require microchips, which adds complexity and may compromise long-term stability. Here, a chipless wireless strain sensor technology based on a novel soft conductor with high cyclic stability is reported. The composite material consists of gold-coated titanium dioxide nanowires embedded in a soft silicone elastomer. The implantable strain sensor is based on an resonant circuit which consists of a stretchable plate capacitor and a coil for inductive readout of its resonance frequency. Successful continuous wireless readout during 50% strain cycles is demonstrated. The sensor element has a Youngs modulus of 260 kPa, similar to that of the bladder in order to not impair physiological bladder expansion. A proof-of-principle measurement on an ex vivo porcine bladder is presented, which shows the feasibility of the presented materials and devices for continuous, wireless strain monitoring of various tissues and organs in vivo.

sted, utgiver, år, opplag, sider
WILEY , 2018. Vol. 3, nr 6, artikkel-id 1800031
Emneord [en]
chipless; soft conductors; strain sensors; stretchable electronics; wireless sensors
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-149356DOI: 10.1002/admt.201800031ISI: 000434947600012OAI: oai:DiVA.org:liu-149356DiVA, id: diva2:1229804
Merknad

Funding Agencies|Swedish Research Council [637-2013-7301]; Swiss Nanotera SpineRepair project, ETH Zurich, SENESCYT; Swedish Government Strategic Research Area in Materials Science on Functional Materials at Linkoping University [2009 00971]; Swedish Foundation for Strategic Research

Tilgjengelig fra: 2018-07-02 Laget: 2018-07-02 Sist oppdatert: 2022-09-15

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Søk i DiVA

Av forfatter/redaktør
Tybrandt, Klas
Av organisasjonen
I samme tidsskrift
Advanced Materials Technologies

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 363 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf